Search NASA⌕ Search

Engineering topics

Xiong, W

Publications and source records attributed to Xiong, W.

SU-F-T-226: QA Management for a Large Institution with Multiple Campuses for FMEA

Purpose: To redesign our radiation therapy QA program with the goal to improve quality, efficiency, and consistency among a growing number of campuses at a large institution. Methods: A QA committee was established with at least one physicist representing each of our six campuses (22 linacs). Weekly meetings were scheduled to advise on and update current procedures, to review end-to-end and other test results, and to prepare composite reports for internal and external audits. QA procedures for treatment and imaging equipment were derived from TG Reports 142 and 66, practice guidelines, and feedback from ACR evaluations. The committee focused on reaching a consensus on a single QA program among all campuses using the same type of equipment and reference data. Since the recommendations for tolerances referenced to baseline data were subject to interpretation in some instances, the committee reviewed the characteristics of all machines and quantified any variations before choosing between treatment planning system (i.e. treatment planning system commissioning data that is representative for all machines) or machine-specific values (i.e. commissioning data of the individual machines) as baseline data. Results: The configured QA program will be followed strictly by all campuses. Inventory of available equipment has been compiled, and additional equipment acquisitions for the QA program are made as needed. Dosimetric characteristics are evaluated for all machines using the same methods to ensure consistency of beam data where possible. In most cases, baseline data refer to treatment planning system commissioning data but machine-specific values are used as reference where it is deemed appropriate. Conclusion: With a uniform QA scheme, variations in QA procedures are kept to a minimum. With a centralized database, data collection and analysis are simplified. This program will facilitate uniformity in patient treatments and analysis of large amounts of QA data campus-wide, which will ultimately facilitate FMEA.

43 PARTICLE ACCELERATORS↗

SU-F-T-253: Volumetric Comparison Between 4D CT Amplitude and Phase Binning Mode

Purpose: Motion artifact in 4DCT images can affect radiation treatment quality. To identify the most robust and accurate binning method, we compare the volume difference between targets delineated on amplitude and phase binned 4DCT scans. Methods: Varian RPM system and CT scanner were used to acquire 4DCTs of a Quasar phantom with embedded cubic and spherical objects having superior-inferior motion. Eight patients’ respiration waveforms were used to drive the phantom. The 4DCT scan was reconstructed into 10 phase and 10 amplitude bins (2 mm slices). A scan of the static phantom was also acquired. For each waveform, sphere and cube volumes were generated automatically on each phase using HU thresholding. Phase (amplitude) ITVs were the union of object volumes over all phase (amplitude) binned images. The sphere and cube volumes measured in the static phantom scan were V{sub sphere}=4.19cc and V{sub cube}=27.0cc. Volume difference (VD) and dice similarity coefficient (DSC) of the ITVs, and mean volume error (MVE) defined as the average target volume percentage difference between each phase image and the static image, were used to evaluate the performance of amplitude and phase binning. Results: Averaged over the eight breathing traces, the VD and DSC of the internal target volume (ITV) between amplitude and phase binning were 3.4%±3.2% (mean ± std) and 95.9%±2.1% for sphere; 2.1%±3.3% and 98.0% ±1.5% for cube, respectively.For all waveforms, the average sphere MVE of amplitude and phase binning was 6.5% ± 5.0% and 8.2%±6.3%, respectively; and the average cube MVE of amplitude and phase binning was 5.7%±3.5%and 12.9%±8.9%, respectively. Conclusion: ITV volume and spatial overlap as assessed by VD and DSC are similar between amplitude and phase binning. Compared to phase binning, amplitude binning results in lower MVE suggesting it is less susceptible to motion artifact.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-05: Effects of Irregular Respiratory Motion On the Positioning Accuracy of Moving Target with Free Breathing Cone-Beam Computerized Tomography

Purpose: Average or maximum intensity projection (AIP or MIP) images derived from 4DCT images are often used as a reference image for target alignment when free breathing Cone-beam CT (FBCBCT) is used for positioning a moving target at treatment. This method can be highly accurate if the patient has stable respiratory motion. However, a patient’s breathing pattern often varies irregularly. The purpose of this study is to investigate the effect of irregular respiration on the positioning accuracy of a moving target with FBCBCT. Methods: Eight patients’ respiratory motion curves were selected to drive a Quasar phantom with embedded cubic and spherical targets. A 4DCT of the moving phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. CBCTs of the phantom driven by the same breathing curves were acquired on a Varian TrueBeam and fused such that the zero positions of moving targets are the same on both CBCT and AIP images. The sphere and cube volumes and centrioid differences (alignment error) determined by MIP, AIP and FBCBCT images were compared. Results: Compared to the volume determined by FBCBCT, the volumes of cube and sphere in MIP images were 22.4%±8.8% and 34.2%±6.2% larger while the volumes in AIP images were 7.1%±6.2% and 2.7%±15.3% larger, respectively. The alignment errors for the cube and sphere with center-center matches between MIP and FBCBCT were 3.5±3.1mm and 3.2±2.3mm, and the alignment errors between AIP and FBCBCT were 2.1±2.6mm and 2.1±1.7mm, respectively. Conclusion: AIP images appear to be superior reference images than MIP images. However, irregular respiratory motions could compromise the positioning accuracy of a moving target if the target center-center match is used to align FBCBCT and AIP images.

60 APPLIED LIFE SCIENCES↗

Solid-state graphene formation via a nickel carbide intermediate phase [Nickel carbide (Ni 3 C) as an intermediate phase for graphene formation]

Direct formation of graphene with controlled number of graphitic layers on dielectric surfaces is highly desired for practical applications. Despite significant progress achieved in understanding the formation of graphene on metallic surfaces through chemical vapor deposition (CVD) of hydrocarbons, very limited research is available elucidating the graphene formation process via rapid thermal processing (RTP) of solid-state amorphous carbon, through which graphene is formed directly on dielectric surfaces accompanied by autonomous nickel evaporation. It is suggested that a metastable hexagonal nickel carbide (Ni 3 C) intermediate phase plays a critical role in transforming amorphous carbon to 2D crystalline graphene and contributing to the autonomous Ni evaporation. Temperature resolved carbon and nickel evolution in the RTP process is investigated using Auger electron spectroscopic (AES) depth profiling and glancing-angle X-ray diffraction (GAXRD). Formation, migration and decomposition of the hexagonal Ni 3 C are confirmed to be responsible for the formation of graphene and the evaporation of Ni at 1100 °C. The Ni 3 C-assisted graphene formation mechanism expands the understanding of Ni-catalyzed graphene formation, and provides insightful guidance for controlled growth of graphene through the solid-state transformation process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The gamma-aminobutyric acid shunt contributes to closing the tricarboxylic acid cycle in Synechocystis sp PCC 6803

A traditional 2-oxoglutarate dehydrogenase complex is missing in the cyanobacterial tricarboxylic acid cycle. To determine pathways that convert 2-oxoglutarate into succinate in the cyanobacterium Synechocystis sp. PCC 6803, a series of mutant strains, Delta sll1981, Delta slr0370, Delta slr1022 and combinations thereof, deficient in 2-oxoglutarate decarboxylase (Sll1981), succinate semialdehyde dehydrogenase (Slr0370), and/or in gamma-aminobutyrate metabolism (Slr1022) were constructed. Like in Pseudomonas aeruginosa, N-acetylornithine aminotransferase, encoded by slr1022, was shown to also function as gamma-aminobutyrate aminotransferase, catalysing gamma-aminobutyrate conversion to succinic semialdehyde. As succinic semialdehyde dehydrogenase converts succinic semialdehyde to succinate, an intact gamma-aminobutyrate shunt is present in Synechocystis. The Delta sll1981 strain, lacking 2-oxoglutarate decarboxylase, exhibited a succinate level that was 60% of that in wild type. However, the succinate level in the Delta slr1022 and Delta slr0370 strains and the Delta sll1981/Delta slr1022 and Delta sll1981/Delta slr0370 double mutants was reduced to 20-40% of that in wild type, suggesting that the gamma-aminobutyrate shunt has a larger impact on metabolite flux to succinate than the pathway via 2-oxoglutarate decarboxylase. C-13-stable isotope analysis indicated that the gamma-aminobutyrate shunt catalysed conversion of glutamate to succinate. Independent of the 2-oxoglutarate decarboxylase bypass, the gamma-aminobutyrate shunt is a major contributor to flux from 2-oxoglutarate and glutamate to succinate in Synechocystis sp. PCC 6803.

Xiong, W↗

SU-E-T-52: Beam Data Comparison for 20 Linear Accelerators in One Network

Purpose: To compare photon beam data for the 20 Varian linear accelerators (TrueBeam, iX, and EX models) in use at five centers in the same network with the intent to model with one set of beam data in Eclipsec. Methods: Varian linear accelerators, TrueBeam (3), 21 EX, iX, and Trilogy (14), and 6 EX (3), installed between 1999 and 2014 have their 6 MV and 15 MV x-ray beams reevaluated. Full commissioning, including output factors (St), percent depth doses (PDD), and off-axis profiles, was recently performed for a TrueBeam with a cc04 ion chamber in an IBA Blue phantom. Similarly, a subset of beam data for each of the other accelerators was measured recently as follows: for 3×3, 10×10, and 30×30 cm{sup 2} field sizes, flatness and penumbra (80–20%) were measured at dmax and 10 cm depths, PDD were measured at 10 and 20 cm depths, and St were measured at 5 cm depth. Measurement results for all machines were compared. Results: For 15 high-energy (6 and 15 MV) and 3 low-energy machines (6MV only): 1) PDD agreed within 1.4% at 10 and 20 cm depths; 2) penumbra agreed within 1.0 mm at dmax and 10 cm depths; 3) flatness was within 1.3% at dmax and 10 cm depths; and 4) with exception of the three low energy machines, output factors were within 1.1% and 0.5% for 3×3 and 30×30 cm{sup 2}, respectively. Measurement uncertainty, not quantified here, accounts for some of these differences. Conclusion: Measured beam data from 15 high-energy Varian linacs are consistent enough that they can be classified using one beam data set in Eclipse. Two additional high-energy machines are removed from this group until their data are further confirmed. Three low-energy machines will be in a separate class based upon differences in output factors (St)

07 ISOTOPE AND RADIATION SOURCES↗

Fast growth of graphene patterns by laser direct writing

Rapid single-step fabrication of graphene patterns was developed using laser-induced chemical vapor deposition (LCVD). A laser beam irradiates a thin nickel foil in a CH{sub 4} and H{sub 2} environment to induce a local temperature rise, thereby allowing the direct writing of graphene patterns in precisely controlled positions at room temperature. Line patterns can be achieved with a single scan without pre- or postprocesses. Surprisingly, the growth rate is several thousand times faster than that of general CVD methods. The discovery and development of the LCVD growth process provide a route for the rapid fabrication of graphene patterns for various applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗