Xiong, Xiaoxiong

Publications and source records attributed to Xiong, Xiaoxiong.

144 records · Page 8

Terra and Aqua MODIS Design, Radiometry, and Geometry in Support of Land Remote Sensing

The NASA Earth Observing System (EOS) mission includes the construction and launch of two nearly identical Moderate Resolution Imaging Spectroradiometer (MODIS) instruments. The MODIS proto-flight model (PFM) is onboard the EOS Terra satellite (formerly EOS AM-1) launched on December 18, 1999 and hereafter referred to as Terra MODIS. Flight model-1 (FM1) is onboard the EOS Aqua satellite (formerly EOS PM-1) launched on May 04, 2002 and referred to as Aqua MODIS. MODIS was developed based on the science community s desire to collect multiyear continuous datasets for monitoring changes in the Earth s land, oceans and atmosphere, and the human contributions to these changes. It was designed to measure discrete spectral bands, which includes many used by a number of heritage sensors, and thus extends the heritage datasets to better understand both long- and short-term changes in the global environment (Barnes and Salomonson 1993; Salomonson et al. 2002; Barnes et al. 2002). The MODIS development, launch, and operation were managed by NASA/Goddard Space Flight Center (GSFC), Greenbelt, Maryland. The sensors were designed, built, and tested by Raytheon/ Santa Barbara Remote Sensing (SBRS), Goleta, California. Each MODIS instrument offers 36 spectral bands, which span the spectral region from the visible (0.41 m) to long-wave infrared (14.4 m). MODIS collects data at three different nadir spatial resolutions: 0.25, 0.5, and 1 km. Key design specifications, such as spectral bandwidths, typical scene radiances, required signal-to-noise ratios (SNR) or noise equivalent temperature differences (NEDT), and primary applications of each MODIS spectral band are summarized in Table 7.1. These parameters were the basis for the MODIS design. More details on the evolution of the NASA EOS and development of the MODIS instruments are provided in Chap. 1. This chapter focuses on the MODIS sensor design, radiometry, and geometry as they apply to land remote sensing. With near-daily coverage of the Earth's surface, MODIS provides comprehensive measurements that enable scientists and policy makers to better understand and effectively manage the natural resources on both regional and global scales. Terra, the first large multisensor EOS satellite, is operated in a 10:30 am (local equatorial crossing time, descending southwards) polar orbit. Aqua, the second multisensor EOS satellite is operated in a 1:30 pm (local equatorial crossing time, ascending northwards) polar orbit. With complementing morning and afternoon observations, the Terra and Aqua MODIS, together with other sensors housed on both satellites, have greatly improved our understanding of the dynamics of the global environmental system.

Xiong, Xiaoxiong↗

Evaluation of Detector-to-Detector and Mirror Side Differences for Terra MODIS Reflective Solar Bands Using Simultaneous MISR Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the five Earth-observing instruments on-board the National Aeronautics and Space Administration (NASA) Earth-Observing System(EOS) Terra spacecraft, launched in December 1999. It has 36 spectral bands with wavelengths ranging from 0.41 to 14.4 mm and collects data at three nadir spatial resolutions: 0.25 km for 2 bands with 40 detectors each, 0.5 km for 5 bands with 20 detectors each and 1 km for the remaining 29 bands with 10 detectors each. MODIS bands are located on four separate focal plane assemblies (FPAs) according to their spectral wavelengths and aligned in the cross-track direction. Detectors of each spectral band are aligned in the along-track direction. MODIS makes observations using a two-sided paddle-wheel scan mirror. Its on-board calibrators (OBCs) for the reflective solar bands (RSBs) include a solar diffuser (SD), a solar diffuser stability monitor (SDSM) and a spectral-radiometric calibration assembly (SRCA). Calibration is performed for each band, detector, sub-sample (for sub-kilometer resolution bands) and mirror side. In this study, a ratio approach is applied to MODIS observed Earth scene reflectances to track the detector-to-detector and mirror side differences. Simultaneous observed reflectances from the Multi-angle Imaging Spectroradiometer (MISR), also onboard the Terra spacecraft, are used with MODIS observed reflectances in this ratio approach for four closely matched spectral bands. Results show that the detector-to-detector difference between two adjacent detectors within each spectral band is typically less than 0.2% and, depending on the wavelengths, the maximum difference among all detectors varies from 0.5% to 0.8%. The mirror side differences are found to be very small for all bands except for band 3 at 0.44 mm. This is the band with the shortest wavelength among the selected matching bands, showing a time-dependent increase for the mirror side difference. This study is part of the effort by the MODIS Characterization Support Team (MCST) in order to track the RSB on-orbit performance for MODIS collection 5 data products. To support MCST efforts for future data re-processing, this analysis will be extended to include more spectral bands and temporal coverage.

Wu, Aisheng↗

Aqua MODIS 8-Year On-Orbit Operation and Calibration

Launched in May 2002, the NASA EOS Aqua MODIS has successfully operated for more than 8 years. Observations from Aqua MODIS and its predecessor, Terra MODIS, have generated an unprecedented amount of data products and made significant contributions to studies of changes in the Earth s system of land, oceans, and atmosphere. MODIS collects data in 36 spectral bands: 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). It has a set of on-board calibrators (OBC), providing sensor on-orbit radiometric, spectral, and spatial calibration and characterization. This paper briefly summarizes Aqua MODIS on-orbit operation and calibration activities and illustrates instrument on-orbit performance from launch to present. Discussions are focused on OBC functions and changes in detector radiometric gains, spectral responses, and spatial registrations. With ongoing calibration effort, Aqua MODIS will continue serving the science community with high quality data products

Xiong, Xiaoxiong↗

Using Lunar Observations to Assess Terra MODIS Thermal Emissive Bands Calibration

MODIS collects data in both the reflected solar and thermal emissive regions using 36 spectral bands. The center wavelengths of these bands cover the3.7 to 14.24 micron region. In addition to using its on-board calibrators (OBC), which include a full aperture solar diffuser (SD) and a blackbody (BB), lunar observations have been scheduled on a regular basis to support both Terra and Aqua MODIS on-orbit calibration and characterization. This paper provides an overview of MODIS lunar observations and their applications for the reflective solar bands (RSB) and thermal emissive bands (TEB) with an emphasis on potential calibration improvements of MODIS band 21 at 3.96 microns. This spectral band has detectors set with low gains to enable fire detection. Methodologies are proposed and examined on the use of lunar observations for the band 21 calibration. Also presented in this paper are preliminary results derived from Terra MODIS lunar observations and remaining challenging issues.

Xiong, Xiaoxiong↗

A Methodology to Assess the Impact of Optical and Electronic Crosstalk in a New Generation of Sensors Using Heritage Sensors

Electronic and optical crosstalk are radiometric challenges that often exist in the focal plane design in many sensors Such as MODIS. A methodology is described to assess the impact due to optical and electronic crosstalk on the measured radiance, and thereafter, the retrieval of geophysical products using MODIS Level I data sets. Based on a postulated set of electronic and optical crosstalk coefficients, and a set of MODIS scenes, we have simulated a system signal contamination on any detector on a focal plane when another detector on that focal plane is stimulated with a geophysical signal. The original MODIS scenes and the crosstalk impacted scenes can be used with validated geophysical algorithms to derive the final data products. Products contaminated with crosstalk are then compared to those without contamination to assess the impact magnitude and location, and will allow us to separate Out-Of-Band (OOB) leaks from hand-to-hand optical crosstalk, and identify potential failures to meet climate research requirements.

Oudrari, Hassan↗

Performance of MODIS Thermal Emissive Bands On-orbit Calibration Algorithms

Two nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) are currently operated on-board the Terra and Aqua spacecrafts, launched in December 1999 and May 2002, respectively. Together, they have produced an unprecedented amount of science data products, which are widely used for the studies of changes in the Earth's system of land, oceans, and atmosphere. MODIS is a cross-track scanning radiometer, which uses a two-sided scan mirror and collects data continuously over a wide scan angle range (+/-55 degree relative to the instrument nadir) each scan of 1.47 seconds. It has 36 spectral bands with wavelengths ranging from visible (VIS) to long-wave infrared (LWIR). MODIS bands 1-19 and 26 are the reflective solar bands (RSB) and bands 20-25 and 27-36 are the thermal emissive bands (TEB). MODIS was developed and designed with improvements made over its heritage sensors (such as AVHRR and Landsat) and, in particular, with more stringent calibration requirements. Because of this, MODIS was built with a set of state-of-art on-board calibrators (OBC), which include a solar diffuser (SD), a solar diffuser stability monitor (SDSM), a blackbody (BB), a spectroradiometric calibration assembly (SRCA), and a space view (SV) port. With the exception of view angle differences, MODIS OBC measurements and the Earth View (EV) observations are made via the same optical path. MODIS TEB have a total of 160 individual TEB detectors (10 per band), which are located on two cold focal plane assemblies (CFPA). For nominal on-orbit operation, the CFPA temperature is controlled at 83K via a passive radiative cooler. For the TEB, the calibration requirements at specified typical scene radiances are less than or equal to 1% with an exception for the fire detection (low gain) band. MODIS TEB on-orbit calibration is performed on a scan-by-scan basis using a quadratic calibration algorithm, and data collected from sensor responses to the onboard BB and SV. The BB serves as the thermal calibration source and the SV provides measurements for the sensor's background and offsets. MODIS on-board BB is a v-grooved plate with its temperature measured using 12 platinum resistive thermistors (PRT) uniformly embedded in the BB substrate. All the BB thermistors were characterized pre-launch with reference to the NIST temperature standards. Unlike typical BB operations in many heritage sensors, which have no temperature control capability, the MODIS on-board BB can be operated at any temperatures between instrument ambient (about 270K) and 315K and can also be varied continuously within this range. This feature has significantly enhanced the MODIS' capability of tracking and updating the TEB nonlinear calibration coefficients over its entire mission. Following a brief description of MODIS TEB on-orbit calibration methodologies and its onboard BB operational activities, this paper provides a comprehensive performance assessment of MODIS TEB quadratic calibration algorithm. It examines the scan-by-scan, orbit-by-orbit, daily, and seasonal variations of detector responses and associated impact due changes in the CFPA and instrument temperatures. Specifically, this paper will analyze the contribution by each individual thermal emissive source term (BB, scan cavity, and scan mirror), the impact on the Level 1 B data product quality due to pre-launch and on-orbit calibration uncertainties. A comparison of Terra and Aqua TEB on-orbit performance, lessons learned, and suggestions for future improvements will also be made.

Xiong, Xiaoxiong↗

MODIS Solar Reflective Calibration Traceability

Long-term climate data records often consist of observations made by multiple sensors. It is, therefore, extremely important to have instrument overlap, to be able to track instrument stability, to quantify, measurement uncertainties, and to establish absolute scale traceable to the International System of Units (SI). The Moderate Resolution Imaging Spectroradiometer (MODIS) is a key instrument for both the Terra and Aqua missions, which were launched in December 1999 and May 2002, respectively. It has 20 reflective solar bands (RSB) with wavelengths from 0.41 to 2.2 micrometers and observes the Earth at three nadir spatial resolutions: 0.25km, 0.5km, and 1km. MODIS RSB on-orbit calibration is reflectance based with reference to the bidirectional reflectance factor (BRF) of its on-board solar diffuser (SD). The SD BRF characterization was made pre-launch by the instrument vendor using reference samples traceable directly to the National Institute of Standards and Technology (NIST). On-orbit SD reflectance degradation is tracked by an on-board solar diffuser monitor (SDSM). This paper provides details of this calibration chain, from prelaunch to on-orbit operation, and associated uncertainty assessments. Using MODIS as an example, this paper also discusses challenges and key design requirements for future missions developed for accurate climate studies.

Xiong, Xiaoxiong↗

Overview of NASA Earth Observing Systems Terra and Aqua Moderate Resolution Imaging Spectroradiometer Instrument Calibration Algorithms and On-Orbit Performance

Since launch, the Terra and Aqua moderate resolution imaging spectroradiometer (MODIS) instruments have successfully operated on-orbit for more than 9 and 6.5 years, respectively. Iv1ODIS, a key instrument for the NASA's Earth Observing System (EOS) missions, was designed to make continuous observations for studies of Earth's land, ocean, and atmospheric properties and to extend existing data records from heritage earth-observing sensors. In addition to frequent global coverage, MODIS observations are made in 36 spectral bands, covering both solar reflective and thermal emissive spectral regions. Nearly 40 data products are routinely generated from MODIS' observations and publicly distributed for a broad range of applications. Both instruments have produced an unprecedented amount of data in support of the science community. As a general reference for understanding sensor operation and calibration, and thus science data quality, we ;provide an overview of the MODIS instruments and their pre-launch calibration and characterization, and describe their on-orbit calibration algorithms and performance. On-orbit results from both Terra and Aqua MODIS radiometric, spectral, and "spatial calibration are discussed. Currently, both instruments, including their on-board calibration devices, are healthy and are expected to continue operation for several }rears to come.

Xiong, Xiaoxiong↗

Using Dome C for Moderate Resolution Imaging Spectroradiometer Calibration Stability and Consistency

Currently, there are two nearly identical moderate resolution imaging spectroradiometer (MODIS) instruments operated in space: one on the Terra spacecraft launched in December 1999 and another on the Aqua spacecraft launched in May 2002. MODIS has 36 spectral bands with wavelengths covering from visible (VIS) to long-wave infrared (LWIR). Since launch, M0DIS observations and data products have significantly enabled studies of changes in the Earth system of land, oceans, and atmosphere. In order to maintain its on-orbit calibration and data product quality, MODIS was built with a comprehensive set of on-board calibrators. MODIS reflective solar bands (RSB) are calibrated on-orbit by a system that consists of a solar diffuser (SD) and a solar diffuser stability monitor(SDSM) on a regular basis. Its thermal emissive bands (TEB) calibration is executed on a scan-by-scan basis using an on-board blackbody (BB). The MODIS Characterization Support Team (MCST) at NASA/GSFC has been responsible for supporting sensor calibration and characterization tasks from pre-launch to post launch. In this paper,we describe current MCST efforts and progress made to examine sensor stability and intercalibration consistency using observations over Dome Concordia, Antarctica. Results show that this site can provide useful calibration reference for Earth-observing sensors.

Xiong, Xiaoxiong↗

Aqua MODIS Thermal Emissive Band On-Orbit Calibration, Characterization, and Performance

The NASA's Earth Observing System Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) has continued to operate with satisfactory performance since its launch in May 2002, exceeding its nominal six-year design lifetime. Its continuous Earth observations have been used to generate many science data products for studies of the Earth's, system. MODIS has 36 spectral bands; 20 reflective solar bands and 16 thermal emissive bands (TEBs). All TEB observations are made at 1-km nadir spatial resolution with spectral wavelengths from 3.7 to 14.4 pm. Primary applications of MODIS TEB 'include surface, cloud, and atmospheric temperatures, water vapor, and cloud top altitude. MODIS TEB on-orbit calibration uses a quadratic algorithm with its calibration coefficients derived using an onboard blackbody (BB). This paper will present Aqua MODIS TEB on-orbit calibration, characterization, and performance over its six-year mission. Examples of instrument thermal behavior, BB temperature stability, detector short-term stability, and changes in long-term response (or system gain) will be presented. Comparisons will also be made with Terra MODIS, launched in December 1999. On-orbit results show that Aqua MODIS and its focal plane temperatures have behaved normally. BB temperature has remained extremely stable with typical scan -to-scan variations of less than +/-0.15 mK. Most TEB detectors continue to exceed their specified signal-to-noise ratio requirements, exhibiting excellent short-term stability and calibration accuracy. Excluding a few noisy detectors, either identified prelaunch or occurring postlaunch, on-orbit changes in TEB responses have been less than 0.5% on an annual basis. By comparison; the overall Aqua TEB performance has been better than that of Terra MODIS,

Xiong, Xiaoxiong↗

On-Orbit Calibration and Performance of Aqua MODIS Reflective Solar Bands

Aqua MODIS has successfully operated on-orbit for more than 6 years since its launch in May 2002, continuously making global observations and improving studies of changes in the Earth's climate and environment. 20 of the 36 MODIS spectral bands, covering wavelengths from 0.41 to 2.2 microns, are the reflective solar bands (RSB). They are calibrated on-orbit using an on-board solar diffuser (SD) and a solar diffuser stability monitor (SDSM). In addition, regularly scheduled lunar observations are made to track the RSB calibration stability. This paper presents Aqua MODIS RSB on-orbit calibration and characterization activities, methodologies, and performance. Included in this study are characterizations of detector signal-to-noise ratio (SNR), short-term stability, and long-term response change. Spectral wavelength dependent degradation of the SD bidirectional reflectance factor (BRF) and scan mirror reflectance, which also varies with angle of incidence (AOI), are examined. On-orbit results show that Aqua MODIS onboard calibrators have performed well, enabling accurate calibration coefficients to be derived and updated for the Level 1B (L1B) production and assuring high quality science data products to be continuously generated and distributed. Since launch, the short-term response, on a scan-by-scan basis, has remained extremely stable for most RSB detectors. With the exception of band 6, there have been no new RSB noisy or inoperable detectors. Like its predecessor, Terra MODIS, launched in December 1999, the Aqua MODIS visible (VIS) spectral bands have experienced relatively large changes, with an annual response decrease (mirror side 1) of 3.6% for band 8 at 0.412 microns, 2.3% for band 9 at 0.443 microns, 1.6% for band 3 at 0.469 microns, and 1.2% for band 10 at 0.488 microns. For other RSB bands with wavelengths greater than 0.5 microns, the annual response changes are typically less than 0.5%. In general, Aqua MODIS optics degradation is smaller than Terra MODIS and the mirror side differences are much smaller. Overall, Aqua MODIS RSB on-orbit performance is better than Terra MODIS.

Xiong, Xiaoxiong↗

Status of Terra and Aqua MODIS Instruments

Currently, two nearly identical MODIS instruments are operating in space: one on the Terra spacecraft launched in December 1999 and another on the Aqua spacecraft launched in May 2002. MODIS has 36 spectral bands with wavelengths covering from visible (VIS) to long-wave infrared (LWIR). Since launch, MODIS observations and data products have contributed significantly to studies of changes in the Earth system of land, oceans, and atmosphere. To maintain its on-orbit calibration and data product quality, MODIS was built with a comprehensive set of on-board calibrators, consisting of a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB) and an on-board blackbody (BB) for the thermal emissive bands (TEB). Both instruments have demonstrated good performance. The primary Level 1 B (LIB) data products are top of the atmosphere (TOA) reflectance for RSB and radiance for TEB This paper provides an overview of MODIS calibration methodologies, activities, lifetime on-orbit performance and challenging issues for each MODIS, the impact on LIB product quality, and lessons learned for future sensors such as the NPOESS VIIRS.

Xiong, Xiaoxiong↗

MODIS On-board Blackbody Performance

Currently, there are two MODIS instruments operated on-orbit: one on-board the Terra spacecraft launched in December 1999 and the other on-board the Aqua spacecraft launched in May 2002. MODIS is a scanning radiometer that has 16 thermal emissive bands (TEBs) in the MWIR and LWIR regions. The remaining spectral bands are in the VISINIR and SWIR regions. The TEBs have a total of 160 detectors (10 detectors per band), which are calibrated on-orbit using an on-board blackbody (BB). MODIS TEB calibration is performed via a quadratic algorithm with its linear calibration coefficients updated on a scan-by-scan basis using each detector's response to the BB. The offset and nonlinear terms of the quadratic calibration equation are stored in a look-up table (LUT). The LUT parameters are derived from pre-launch calibration and updated on-orbit from BB observations, as needed. Typically, the BB is set at a fixed temperature. Periodically, a warm-up and cool-down activity is performed, which enables the BB temperature to be varied from instrument ambient up to 315K. The temperature of the BB is measured each scan using 12 thermistors, which were fully characterized pre-launch with reference to the NIST temperature scale. This paper describes MODIS on-board BB operational activities and performance. The TEB detector response (short-term stability and long-term changes) and noise characterization results derived from BB observations and their impact on the TEB calibration uncertainty are also presented.

Xiong, Xiaoxiong↗

MODIS Solar Diffuser On-orbit Performance

MODIS is a key instrument for the NASA Earth Observing System (EOS), currently operated on both the Terra and Aqua missions. Each MODIS instrument has 20 reflective solar bands (RSBs) and 16 thermal emissive bands (TEBs). MODIS RSB on-orbit calibration is reflectance based using an on-board solar diffuser (SD). The SD bi-directional reflectance factors (BRFs) were characterized pre-launch using reference diffuser samples, which are traceable to NIST reflectance standards. The SD BRF on-orbit degradation (or change) is tracked by another onboard device, called the solar diffuser stability monitor (SDSM). The SDSM is operated during each scheduled SD calibration event, making alternate observations of direct sunlight and the diffusely reflected sunlight from the SD. The time series of the ratios of SDSM's SD view to its Sun view provide SD degradation information. This paper presents and compares the Terra and Aqua MODIS SD on-orbit performance. Results show that the SD on-orbit degradation depends on the amount of solar exposure of the SD plate. In addition, it is strongly wavelengthdependent, with a larger degradation rate at shorter wavelengths. For Terra MODIS, an SD door anomaly occurred in May 2003 that led to a decision to fix the door permanently at an "open" position. Since then, the SD degradation rate has significantly increased due to more frequent solar exposure. As expected, the SD on-orbit performance directly impacts the RSB calibration performance. The lessons learned from MODIS on-orbit calibration will provide useful insights into the development and operation of future SD calibration systems.

Xiong, Xiaoxiong↗

Comparison of Terra and Aqua MODIS VIS Bands On-Orbit Response

The Moderate Resolution Imaging Spectroradiometer (MODIS) has 36 spectral bands with a total of 490 detectors, covering spectral regions in the visible (VIS), near-infrared (NIR), short-wave infrared (SWIR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). MODIS is a cross-track scanning radiometer which collects data using a rotating scan mirror (both sides) over a wide range of scan angles. The VIS, NIR, and SWIR bands (bands 1-19 and 26) make measurements of daytime surface reflected radiances, thus are referred to as the reflective solar bands (RSB). MODIS was built with a complete set of on-board calibrators, capable of providing radiometric, spatial, and spectral calibration and characterization during its entire mission. The RSB on-orbit calibration is primarily provided using a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). The SD and SDSM calibration system is operated on a regular (weekly to bi-weekly) basis. The spectro-radiometric calibration assembly (SRCA) is another on-hoard calibrator that also provides RSB radiometric calibration support. For this purpose, the SRCA is operated in a radiometric mode on a monthly basis. A complete SRCA radiometric calibration is performed using different lamp configurations, or different radiance levels, to cover the range of RSB gain. Two additional SRCA modes with slightly different configurations are designed and operated for sensor on-orbit spectral and spatial characterization. In addition to its on-hoard calibrators, each MODIS makes monthly lunar observations to monitor RSB radiometric calibration stability. The MODIS lunar observations are made through its space view (SV) port at nearly the same lunar phase angles via spacecraft roll maneuvers. The SD, SRCA, and lunar measurements are made at different scan angles and data samples are collected for all spectral bands and detectors using both sides of the scan minor. Since launch, Terra and Aqua MODIS have operated successfully for more than 8 years and 6 years, respectively. Many SD/SDSM, SRCA, and lunar observations have been made by each instrument and used to derive RSB on-orbit calibration parameters, enabling corrections for sensor response changes and changes of the response versus scan angle (RVS). In general, the RSB calibration parameters are updated regularly into the MODIS Level 1B (LIB) code in support of continuous data processing for all MODIS science data products. This paper provides a brief description of MODIS RSB calibration methodologies and approaches, and summarizes on-orbit changes of their responses (gains), particularly for the VIS spectral bands.

Xiong, Xiaoxiong↗

Assessment of MODIS Scan Mirror Reflectance Changes On-Orbit

Since launch, the NASA EOS Terra and Aqua MODIS have operated successfully for more than 8 and 6 years, respectively. MODIS collects data using a two-sided scan mirror over a large scan angular range. The scan mirror is made of a polished, nickel-plated beryllium base coated with high purity silver, which is then over-coated with the Denton proprietary silicon monoxide and silicon dioxide mixture. The scan mirror's reflectance was characterized pre-launch using its witness samples, and the response versus scan angle was measured at the sensor system level. In this study, we present an assessment of MODIS scan mirror on-orbit degradation by examining changes of spectral band response over each sensor's mission lifetime. Results show that the scan mirror's optical properties for both Terra and Aqua MODIS have experienced significant degradation since launch in the VIS spectral region, which is mirror side dependent as well as scan angle dependent. In general, the mirror degradation is more severe for Terra MODIS than Aqua MODIS, especially during recent years. For Terra MODIS, the degradation rate is noticeably different between the mirror sides. On the other hand, there has been little mirror side dependent difference for Aqua MODIS.

Xiong, Xiaoxiong↗

Sensitivity Study for Sensor Optical and Electric Crosstalk Based on Spectral Measurements: An Application to Developmental Sensors Using Heritage Sensors Such As MODIS

The process of developing new sensors for space flight frequently builds upon the designs and experience of existing heritage space flight sensors. Frequently in the development and testing of new sensors, problems are encountered that pose the risk of serious impact on successful retrieval of geophysical products. This paper describes an approach to assess the importance of optical and electronic cross-talk on retrieval of geophysical products using new MODIS-like sensors through the use of MODIS data sets. These approaches may be extended to any sensor characteristic and any sensor where that characteristic may impact the Level 1 products so long as validated geophysical products are being developed from the heritage sensor. In this study, a set of electronic and/or optical cross-talk coefficients are postulated. These coefficients are sender-receiver influence coefficients and represent a sensor signal contamination on any detector on a focal plane when another band's detectors on that focal plane are stimulated with a monochromatic light. The approach involves using the postulated cross-talk coefficients on an actual set of MODIS data granules. The original MODIS data granules and the cross-talk impacted granules are used with validated geophysical algorithms to create the derived products. Comparison of the products produced with the original and cross-talk impacted granules indicates potential problems, if any, with the characteristics of the developmental sensor that are being studied.

Butler, James J.↗

Multiyear On-orbit Calibration and Performance of Terra MODIS Thermal Emissive Bands

Since launch in December 1999, Terra MODIS has been making continuous Earth observations for more than seven years. It has produced a broad range of land, ocean, and atmospheric science data products for improvements in studies of global climate and environmental change. Among its 36 spectral bands, there are 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). MODIS thermal emissive bands cover the mid-wave infrared (MWIR) and long-wave infrared (LWIR) spectral regions with wavelengths from 3.7 to 14.4pm. They are calibrated on-orbit using an on-board blackbody (BB) with its temperature measured by a set of thermistors on a scan-by-scan basis. This paper will provide a brief overview of MODIS TEB calibration and characterization methodologies and illustrate on-board BB functions and TEB performance over more than seven years of on-orbit operation and calibration. Discussions will be focused on TEB detector short-term stability and noise characterization, and changes in long-term response (or system gain). Results show that Terra MODIS BB operation has been extremely stable since launch. When operated at its nominal controlled temperature of 290K, the BB temperature variation is typically less than +0.30mK on a scan-by-scan basis and there has been no time-dependent temperature drift. In addition to excellent short-term stability, most TEB detectors continue to meet or exceed their specified noise characterization requirements, thus enabling calibration accuracy and science data product quality to be maintained. Excluding the noisy detectors identified pre-launch and those that occurred post-launch, the changes in TEB responses have been less than 0.7% on an annual basis. The optical leak corrections applied to bands 32-36 have been effective and stable over the entire mission

Xiong, Xiaoxiong↗