Search NASA⌕ Search

Engineering topics

Xu, L. Q.

Publications and source records attributed to Xu, L. Q..

Analysis of beam ion driven Alfvén eigenmode stability induced by Tungsten contamination in EAST

Alfvén eigenmodes (AE) activity is observed in the EAST high β N and low B T discharge 93910, operation scenario dedicated to explore the ITER baseline scenario. AEs are triggered after the plasma is contaminated by Tungsten that causes an abrupt variation of the thermal plasma and energetic particles (EPs) profiles. The aim of the present study is to analyze the AE stability in the 93910 discharge using the gyro-fluid code FAR3d, identifying the AE stability trends by comparing the plasma before and after the Tungsten contamination. Tungsten contamination causes the destabilization of Toroidal AEs (TAE) and Energetic particle modes (EPMs) in the same frequency range and radial location with respect to the experimental observation and M3D-K/GTAW code results. Next, a set of parametric studies are performed to analyze the effect of the thermal plasma and EP parameters on the AE stability. The analysis indicates a lower EP β threshold for the AEs destabilization if the EP energy increases, an improved AE stability of on-axis NBI configurations due to the stronger continuum damping in the inner plasma region as well as a large enhancement of the EP drive as the thermal ion density increases due to a higher ratio of the EP and Alfven velocities. Consequently, the simulations indicate the increment of the thermal ion density after the Tungsten contamination could be the main cause of the AE/EPM destabilization.

AE↗

First results of Ne shattered pellet injection for mitigating plasma disruption with full metal wall in EAST tokamak

Disruption mitigation poses a significant and unresolved challenge for ITER and future fusion reactor devices. To mitigate the effect of plasma disruption, a Shattered Pellet Injection (SPI) system has been developed and the first rapid shutdown experiments have been successfully performed in the Experimental Advanced Superconducting Tokamak with full metal wall. The experiments confirmed the system’s capability to inject 5 mm diameter neon (Ne) pellets at velocities ranging from 100 to 400 m s −1 , with a maximum injected quantity of 13.2 Pa m 3 . Compared to unmitigated disruptions, the total radiation power was significantly higher with the respective use of SPI and Massive Gas Injection (MGI). Additionally, the radiation distribution and divertor heat flux were compared between SPI and MGI methods. The results demonstrated that SPI exhibited shorter cooling time, stronger core radiation and more uniform poloidal radiation distribution compared to MGI, indicating deeper deposition using SPI. Furthermore, during plasma shutdown, the electron temperature and peak heat flux near outer divertor strike points were reduced by 40% and 50% respectively, with SPI, in comparison to MGI. These findings serve as a valuable reference for implementing SPI technology as the baseline approach for disruption mitigation in ITER.

EAST↗

Long-pulse high-performance H-mode plasmas achieved on EAST

A record duration of a 310 s H-mode plasma (H 98y2 ~ 1.3, n e /n GW ~ 0.7, f BS > 50%) has been recently achieved on experimental advanced superconducting tokamak (EAST) with metal walls, exploiting the device's improved long-pulse capabilities. The experiment demonstrates good control of tungsten concentration, core/edge MHD stability, and particle and heat exhaust with an ITER-like tungsten divertor and zero injected torque, establishing a milestone on the path to steady-state long-pulse high-performance scenarios in support of ITER and CFETR. Important synergistic effects are leveraged toward this result, which relies purely on radio frequency (RF) powers for heating and current drive (H&CD). On-axis electron cyclotron heating enhances the H&CD efficiency from lower hybrid wave injection, increasing confinement quality and enabling fully non-inductive operation at high density (n e /n GW ~ 70%) and high poloidal beta (β P ~ 2.5). A small-amplitude grassy edge localized mode regime facilitates the RF power coupling to the H-mode edge and reduces divertor sputtering/erosion. The high energy confinement quality (H 98y2 ~ 1.3) is achieved with the experimental and simulated results pointing to the strong effect of Shafranov shift on turbulence. Transport analysis suggests that trapped electron modes dominate in the core region during the record discharge. The detailed physics processes (RF synergy, core-edge integration, confinement properties, etc.) of the steady-state operation will be illustrated in the content. In the future, EAST will aim at accessing more relevant dimensionless parameters to develop long-pulse high-performance plasma toward ITER and CFETR steady-state advanced operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma heating by electron cyclotron wave and the temperature effects on lower hybrid current drive on EAST

This paper presents the progress in the long—pulse operation of the electron cyclotron (EC) system and the achievements in high—electron temperature plasmas by the combined EC and lower hybrid (LH) waves heating since the EC system was built in 2015. An electron temperature of up to 12 keV with a duration over 100 s was realized by the simultaneous heating of EC and LH waves at the line-averaged density ${\bar n_{\text{e}}}$ ~1.8 × 10 19 m –3 . The plasma heating effect strongly depends on the location of EC power deposition. H-mode plasmas with solely EC wave auxiliary heating have been obtained on EAST for the first time. These H-mode discharges show an enhanced confinement factor H 98(y,2) around 1.0, which is higher than the previous H-mode using LH power alone (Xu et al 2011 Nucl. Fusion 51 072001). The total heating power is very close to the threshold value for L–H transition according to the international tokamak scaling. In addition to the temperature effects inside the separatrix, higher electron temperature produced by EC wave is found to reduce the LH power loss in the scrape-off layer due to collisional absorption, which is beneficial to further increase the LH current drive efficiency. Ray-tracing/Fokker–Planck modeling results indicate that higher electron temperature can shorten the LH wave propagation on EAST in a multiple-pass regime, thus decreasing the collisional dissipation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗