Search NASA⌕ Search

Engineering topics

Xu, Xiaoming

Publications and source records attributed to Xu, Xiaoming.

Critical needs to close monitoring gaps in pan-tropical wetland CH 4 emissions

Global wetlands are the largest and most uncertain natural source of atmospheric methane (CH 4 ). The FLUXNET-CH 4 synthesis initiative has established a global network of flux tower infrastructure, offering valuable data products and fostering a dedicated community for the measurement and analysis of methane flux data. Existing studies using the FLUXNET-CH 4 Community Product v1.0 have provided invaluable insights into the drivers of ecosystem-to-regional spatial patterns and daily-to-decadal temporal dynamics in temperate, boreal, and Arctic climate regions. However, as the wetland CH 4 monitoring network grows, there is a critical knowledge gap about where new monitoring infrastructure ought to be located to improve understanding of the global wetland CH 4 budget. Here we address this gap with a spatial representativeness analysis at existing and hypothetical observation sites, using 16 process-based wetland biogeochemistry models and machine learning. We find that, in addition to eddy covariance monitoring sites, existing chamber sites are important complements, especially over high latitudes and the tropics. Furthermore, expanding the current monitoring network for wetland CH 4 emissions should prioritize, first, tropical and second, sub-tropical semi-arid wetland regions. Considering those new hypothetical wetland sites from tropical and semi-arid climate zones could significantly improve global estimates of wetland CH 4 emissions and reduce bias by 79% (from 76 to 16 TgCH 4 y -1 ), compared with using solely existing monitoring networks. Our study thus demonstrates an approach for long-term strategic expansion of flux observations.

54 ENVIRONMENTAL SCIENCES↗

The effect of food vehicles on in vitro performance of pantoprazole sodium delayed release sprinkle formulation

Certain patient populations, including children, the elderly or people with dysphagia, find swallowing whole medications such as tablets and capsules difficult. To facilitate oral administration of drugs in such patients, a common practice is to sprinkle the drug products (e.g., usually after crushing the tablet or opening the capsule) on food vehicles before consumption which improves swallowability. Thus, evaluation of the impact of food vehicles on the potency and stability of the administered drug product is important. Here, the aim of the current study was to evaluate the physicochemical properties (viscosity, pH, and water content) of common food vehicles used for sprinkle administration (e.g., apple juice, applesauce, pudding, yogurt, and milk) and their impacts on the in vitro performance (i.e., dissolution) of pantoprazole sodium delayed release (DR) drug products. The food vehicles evaluated exhibited marked difference in viscosity, pH and water content. Notably, the pH of the food as well as the interaction between food vehicle pH and drug-food contact time were the most significant factors affecting the in vitro performance of pantoprazole sodium DR granules. For example, the dissolution of pantoprazole sodium DR granules sprinkled on food vehicles of low pH (e.g., apple juice or applesauce) for short durations remained unchanged compared with the control group (i.e., without mixing with food vehicles). However, use of high pH food vehicles (e.g., milk) with prolonged contact time (e.g., 2h) resulted in accelerated pantoprazole release, drug degradation and loss of potency. Overall, a thorough assessment of physicochemical properties of food vehicles and formulation characteristics are a necessary part of the development of sprinkle formulations.

60 APPLIED LIFE SCIENCES↗

Determining critical overlap concentration of polyethylene oxide to support excipient safety assessment of opioid products

Intravenous administration of abuse-deterrent opioid products poses high safety risks, in part due to the presence of high molecular weight polymeric excipients. Previous in vivo studies in animal models have shown that the higher molecular weight (Mw) polymeric excipients like polyethylene oxide (PEO) were directly linked to such adverse responses as intravenous hemolysis and kidney damage. PEO polymers have been widely used in abuse-deterrent formulations (ADF) of opioid products, adding to concerns over the general safety of the opioid category due to the unknown safety risk from abuse via unintended routes. Here, the current study focused on the determination of the critical overlap concentration (c*) at various PEO molecular weights to aid in explaining differences in observed adverse responses from previous animal studies on the intravenous administration of PEO solutions. Adverse in vivo responses may be related to the viscoelastic regime of the polymer solution, which depends not only on Mw but also on concentration. Having a localized polymer concentration in the blood above the c*, i.e., the transition from the dilute to semi-dilute entangled viscoelastic regime, may influence the flow behavior and interactions of cells in the blood. The relationship of c* to this combination of physical, chemical, and rheological effects is a possible driving force behind adverse in vivo responses.

60 APPLIED LIFE SCIENCES↗

Understanding syringeability and injectability of high molecular weight PEO solution through time-dependent force-distance profiles

Opioid medications play a vital role in treating moderate to severe pain. Unfortunately, many drug misusers and abusers attempt to alter the formulations or properties of these drugs by manipulation, (e.g., crushing, chewing, smoking, snorting, injecting). The intravenous (IV) route is most dangerous to abusers, as the drugs directly enter the circulatory system and produce intense euphoria. To obtain a full understanding of the impact of syringe factors (e.g., needle gauge size, needle length, syringe barrel size), on the ease of injection, we undertook a comprehensive assessment of syringeability and injectability of manipulated abuse-deterrent formulations (ADFs). A texture analyzer-based testing method was developed for the measurement of the resistance force of pulling, holding, and pushing phases of injections. Results showed that the finer needle gauge sizes required higher injection force to withdraw drug solutions. In addition, the syringed liquid volume was highly dependent on needle gauge size, holding time, and sample viscosity. In most cases, a lower needle gauge number and a longer holding time increased the syringed volume. Needle length was highly correlated to injection force (R 2 = 0.99). Using longer needles to inject drug solution requires greater force. Furthermore, large barrel size was correlated to pushing force (R 2 = 0.99); thus, increasing the difficulty of pushing the plunger of a large syringe with one hand. Lastly, relationships between injection force, sample viscosity, and testing conditions were elucidated using a mathematical model, which could be used in the future to assess and predict injection force of solution samples.

60 APPLIED LIFE SCIENCES↗