Characterization of x-ray photocathode in transmission mode for imaging application

The performance of an Al x-ray transmission photocathode was experimentally characterized by measuring the total electron yield from backsurface photocathodes of varying thickness. It was demonstrated that the backsurface electron yield is proportional to the x-ray photocurrent transmitted through the photocathode for thicknesses thicker than the optimum thickness. The optimum photocathode thickness with the highest conversion efficiency was found to be approximately 70 nm at 2.963 keV. An escape depth of the secondary electrons was determined to be approximately 13 nm from the yield-versus-thickness data fitted with a semiempirical equation. Using this parameter, the dependence of the optimum photocathode thickness on the x-ray energy was calculated for the 30-10000 eV range. As one example of imaging applications, different photoemission images in the transmission and reflection modes are also presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate and quick calibration method for polarization-modulation spectroscopy using an ac-modulated polarizing undulator

An accurate calibration method in which an ac-modulated polarizing undulator is used for polarization modulation spectroscopy such as circular dichroism (CD) and linear dichroism (LD) has been proposed and successfully applied to vacuum ultraviolet (vuv) CD and LD spectra measured at beamline BL-5B in the electron storage ring, TERAS, at AIST. This calibration method employs an undulator-modulation spectroscopic method with a multireflection polarimeter, and it uses electronic and optical elements identical to those used for the CD and LD measurements. This method regards the polarimeter as a standard sample for the CD and LD measurements in the vuv region in which a standard sample has not yet been established. The calibration factors for the CD and LD spectra are obtained over a wide range of wavelengths, from 120 to 230 nm, at TERAS BL-5B. The calibrated CD and LD spectra measured at TERAS exhibit good agreement with the standard spectra for wavelengths greater than 170 nm; the mean differences between the standard and calibrated CD and LD spectra are approximately 7% and 4%, respectively. This method enables a remarkable reduction in the experimental time, from approximately 1 h to less than 10 min that is sufficient to observe the storage-ring current dependence of the calibration factors. This method can be applied to the calibration of vuv-CD spectra measured using a conventional photoelastic modulator and for performing an accurate analysis of protein secondary structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent progress in vacuum-ultraviolet polarization modulation spectroscopy using polarizing undulator at the TERAS BL5 beamline

Polarization modulation spectroscopy using an Onuki-type undulator is a useful technique for circular dichroism study in the vacuum-ultraviolet region. We have been developing the vacuum-ultraviolet circular dichroism (vuv-CD) spectroscopy in TERAS BL5 beamline at AIST. This paper describes recent improvements in our instrumentation and methods of analysis to achieve precise and absolute measurements. The CD signal is usually accompanied by experimental artifacts, and elimination of all possible artifacts is the key issue for making reliable measurements. After improving beamline optical system, light flux monitor, and undulator operation method, the base line shift of the CD spectrum is suppressed less than 3x10{sup -4}. Sample manipulation and data processing procedures are also described and absolute CD spectrum can be obtained even for linear anisotropic sample. These progresses lead to more quantitative comparison of experimental with calculation on vuv-CD spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗