Search NASA⌕ Search

Engineering topics

Yamamoto, Akira

Publications and source records attributed to Yamamoto, Akira.

At least 19 records

Transcatheter Arterial Chemoembolization for Treatment-Naive Hepatocellular Carcinoma Has Different Treatment Effects Depending on Central or Peripheral Tumor Location

Introduction: The purpose of this study was to evaluate the treatment efficacy of transcatheter arterial chemoembolization (TACE) for treatment-naive hepatocellular carcinoma (HCC) according to tumor location and burden. Methods: Between 2010 and 2019, consecutive patients who underwent TACE as the first treatment were enrolled. Tumors were classified into two categories based on their location, as central or peripheral tumors. Tumors in the central zone, which is within 1 cm of the main trunk or the first branch of the portal vein, were classified as central tumors, while those located in the peripheral zone were classified as peripheral tumors. Patients were grouped according to the HCC location and up-to-7 criteria. Patients with central tumors were classified into the central arm and those with only peripheral tumors were classified into the peripheral arm. Patients within and beyond the up-to-7 criteria were classified into the up-to-7 in and up-to-7 out-groups, respectively. Local recurrence-free survival (LRFS) and progression-free survival (PFS) were compared per nodule (central tumor vs. peripheral tumor) and per patient (central arm vs. peripheral arm), respectively. The prognostic factors of LRFS and PFS were analyzed by univariate and multivariate analyses. Results: A total of 174 treatment-naive patients with 352 HCCs were retrospectively enrolled. Ninety-six patients and 130 lesions were selected by propensity score matching. Median LRFS was longer for peripheral tumors than central tumors (not reached vs. 3.3 months, p < 0.001). Median PFS was 17.1 months (8.3–24.9) in the peripheral arm and up-to-7 in, 7.0 months (3.3–12.7) in the peripheral arm and up-to-7 out, 8.4 months (4.0–12.6) in the central arm and up-to-7 in, and 3.0 months (1.2–4.9) in the central arm and up-to-7 out-groups. The peripheral arm and up-to-7 in-groups had significantly longer PFS than the other three groups (p = 0.013, p = 0.015, p < 0.001, respectively). Multivariate analysis confirmed that the central zone and central arm were associated with high adjusted hazard ratios for tumor recurrence or death (2.87, p < 0.001; 2.89, p < 0.001, respectively). Conclusion: Treatment-naive HCCs in the peripheral zone had a longer LRFS and PFS following TACE compared to those in the central zone.

Gastroenterology & Hepatology↗

Crab Cavities for ILC

For the 14 mrad crossing angle proposed, crab cavity systems are fundamentally anticipated for the viable operation of the International Linear Collider (ILC), in order to maximise its luminosity performance. Since 2021, a specialist development team have been defining optimum crab cavity technologies which can fulfil the operational requirements for ILC, both for its baseline centre-of-mass energy of 250 GeV, but also extending those requirements out to higher beam collision intensities. Five design teams have established crab cavity technology solutions, which have the capability to also operate up to 1 TeV centre-of-mass. This presentation showcases the key performance capabilities of these designs and their associated benefits for both manufacture and integration into the ILC Interaction Region. The recommended outcome of the recently conducted crab cavity technology down-selection, will also be highlighted.

43 PARTICLE ACCELERATORS↗

Study of Conduction-Cooled Superconducting Quadrupole Magnets Combined with Dipole Correctors for the ILC Main Linac

A superconducting rf (SRF) cryomodule for International Linear Collider(ILC) Main Linac equips focus/steering magnets. The magnets are "superferric" magnets with four superconducting (SC) race track coils conductively cooled from the cryomodule LHe supply pipe. The quadrupole field gradient and dipole field are 40 T/m and 0.1 T, respectively. The magnet length and iron-pole radius are 1 m and 0.045 m, respectively. It is known that dark current is generated at SRF cavities and accelerated through the following linac string. The dark current reaches and heats the SC magnets. It is estimated that the power deposition in the magnet may reach more than a few watts and temperature of the SC coils may locally reach to critical temperature of NbTi. It is important to make the magnet not reach quench with sufficient conduction cooling. We aim to realize the SC magnet which can stably operate under such condition. We plan to develop test coils made of three types of SC materials, NbTi, Nb₃Sn, and MgB₂ and study thermal characteristics and stability . We will develop a short model magnet, based on the test coil results. Here, we will present the magnet design study and the R&D plan.

43 PARTICLE ACCELERATORS↗

Better Particle Accelerators with SRF Technology

The use of superconducting radio frequency (SRF) technology is a driving force in the development of particle accelerators. Scientists from around the globe are working together to develop the newest materials and techniques to improve the quality and efficiency of the SRF cavities that are essential for this technology.

43 PARTICLE ACCELERATORS↗

Ingot Nb based SRF technology for the International Linear Collider

The International Linear Collider (ILC) is anticipated to be built as the next energy-frontier electron-positron colliding accelerator with a global effort in particle physics. Niobium based Superconducting Radio-Frequency (SRF) technology is required to provide beam-accelerating structure with elliptical cavity strings to linearly accelerate the electron and positron beams up to 250 GeV and to realize a center-of-mass energy of 500 GeV in collisions. The accelerator design and R&D efforts progressed, and the ILC Technical Design Report (ILC-TDR) was published in 2013. Niobium will take a critical role to generate electric field gradient with a frequency of 1.3 GHz, for accelerating the beam with the best efficiency, in energy balance, using RF superconductivity. This paper discusses a technical approach to provide Nb material (ingot) and thin disks for producing the elliptical cavity structure, with direct slicing from Nb ingot having sufficiently optimized purity and residual resistance ration (RRR) necessary for the ILC SRF cavities.

43 PARTICLE ACCELERATORS↗

Superconducting Magnets for Particle Accelerators

In this study, we summarize the evolution and contributions of superconducting magnets to particle accelerators as chronicled over the last 50 years of Particle Accelerator Conferences (PAC, NA-PAC and IPAC). We begin with an historical overview based primarily on PAC Proceedings augmented with references to key milestones in the development of superconducting magnets for particle accelerators. We then provide some illustrative examples of applications that have occurred over the past 50 years, focusing on those that have either been realized in practice or provided technical development for other projects, with discussion of possible future applications.

43 PARTICLE ACCELERATORS↗

The International Linear Collider Progress Report 2015

The ILC technical design is now being adapted to the preferred candidate site. Changes in layout are being managed by a rigorous change-control procedure. Series production of cavities for the European XFEL has shown that cavities can be mass-produced in industry with a performance well above XFEL requirements and close to that needed for the ILC. A number of technical developments are under way with a view to further reducing the ILC cost. This work must continue through the preparatory stage for ILC construction once resources become available. A summary of the design updates and of the further preparatory work needed is summarized in tabular form in the Appendix.

43 PARTICLE ACCELERATORS↗

Test results of a Nb 3 Al/Nb 3 Sn subscale magnet for accelerator application

The High Energy Accelerator Research Organization (KEK) has been developing a Nb 3 Al and Nb 3 Sn subscale magnet to establish the technology for a high-field accelerator magnet. The development goals are a feasibility demonstration for a Nb 3 Al cable and the technology acquisition of magnet fabrication with Nb 3 Al superconductors. KEK developed two double-pancake racetrack coils with Rutherford-type cables composed of 28 Nb 3 Al wires processed by rapid heating, quenching, and transformation in collaboration with the National Institute for Materials Science and the Fermi National Accelerator Laboratory. The magnet was fabricated to efficiently generate a high magnetic field in a minimum-gap common-coil configuration with two Nb 3 Al coils sandwiched between two Nb 3 Sn coils produced by the Lawrence Berkeley National Laboratory. A shell-based structure and a “bladder and key” technique have been used for adjusting coil prestress during both the magnet assembly and the cool down. In the first excitation test of the magnet at 4.5 K performed in June 2014, the highest quench current of the Nb 3 Sn coil, i.e., 9667 A, was reached at 40 A/s corresponding to 9.0 T in the Nb 3 Sn coil and 8.2 T in the Nb 3 Al coil. The quench characteristics of the magnet were studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiofrequency Ablation of Liver Tumors in Combination with Local OK-432 Injection Prolongs Survival and Suppresses Distant Tumor Growth in the Rabbit Model with Intra- and Extrahepatic VX2 Tumors

Purpose: To evaluate survival and distant tumor growth after radiofrequency ablation (RFA) and local OK-432 injection at a single tumor site in a rabbit model with intra- and extrahepatic VX2 tumors and to examine the effect of this combination therapy, which we termed immuno-radiofrequency ablation (immunoRFA), on systemic antitumor immunity in a rechallenge test. Methods: Our institutional animal care committee approved all experiments. VX2 tumors were implanted to three sites: two in the liver and one in the left ear. Rabbits were randomized into four groups of seven to receive control, RFA alone, OK-432 alone, and immunoRFA treatments at a single liver tumor at 1 week after implantation. Untreated liver and ear tumor volumes were measured after the treatment. As the rechallenge test, tumors were reimplanted into the right ear of rabbits, which survived the 35 weeks and were followed up without additional treatment. Statistical significance was examined by log-rank test for survival and Student's t test for tumor volume. Results: Survival was significantly prolonged in the immunoRFA group compared to the other three groups (P < 0.05). Untreated liver and ear tumor sizes became significantly smaller after immunoRFA compared to controls (P < 0.05). In the rechallenge test, the reimplanted tumors regressed without further therapy compared to the ear tumors of the control group (P < 0.05). Conclusion: ImmunoRFA led to improved survival and suppression of distant untreated tumor growth. Decreases in size of the distant untreated tumors and reimplanted tumors suggested that systemic antitumor immunity was enhanced by immunoRFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a cryogenic load frame for the neutron diffractometer at Takumi in Japan Proton Accelerator Research Complex

To prepare for projects such as the Large Hadron Collider upgrade, International Thermonuclear Experimental Reactor and Demonstration reactor, it is important to form a clear understanding of stress-strain properties of the materials that make up superconducting magnets. Thus, we have been studying the mechanical properties of superconducting wires using neutron diffraction measurements. To simulate operational conditions such as temperature, stress, and strain, we developed a cryogenic load frame for stress-strain measurements of materials using a neutron diffractometer at Japan Proton Accelerator Research Complex (J-PARC) Takumi beam line. The maximum load that can be applied to a sample using an external driving machine is 50 kN. Using a Gifford-MacMahon cryocooler, samples can be measured down to temperatures below 10 K when loaded. In the present paper, we describe the details of the cryogenic load frame with its test results by using type-304 stainless steel wire.

43 PARTICLE ACCELERATORS↗

International Linear Collider-A Technical Progress Report

The International Linear Collider: A Technical Progress Report marks the halfway point towards the Global Design Effort fulfilling its mandate to follow up the ILC Reference Design Report with a more optimised Technical Design Report (TDR) by the end of 2012. The TDR will be based on much of the work reported here and will contain all the elements needed to propose the ILC to collaborating governments, including a technical design and implementation plan that are realistic and have been better optimised for performance, cost and risk. We are on track to develop detailed plans for the ILC, such that once results from the Large Hadron Collider (LHC) at CERN establish the main science goals and parameters of the next machine, we will be in good position to make a strong proposal for this new major global project in particle physics. The two overriding issues for the ILC R&D programme are to demonstrate that the technical requirements for the accelerator are achievable with practical technologies, and that the ambitious physics goals can be addressed by realistic ILC detectors. This GDE interim report documents the impressive progress on the accelerator technologies that can make the ILC a reality. It highlights results of the technological demonstrations that are giving the community increased confidence that we will be ready to proceed with an ILC project following the TDR. The companion detector and physics report document likewise demonstrates how detector designs can meet the ambitious and detailed physics goals set out by the ILC Steering Committee. LHC results will likely affect the requirements for the machine design and the detectors, and we are monitoring that very closely, intending to adapt our design as those results become available.

43 PARTICLE ACCELERATORS↗

A Survey of Pressure Vessel Code Compliance for Superconducting RF Cryomodules

Superconducting radio frequency (SRF) cavities made from niobium and cooled with liquid helium are becoming key components of many particle accelerators. The helium vessels surrounding the RF cavities, portions of the niobium cavities themselves, and also possibly the vacuum vessels containing these assemblies, generally fall under the scope of local and national pressure vessel codes. In the U.S., Department of Energy rules require national laboratories to follow national consensus pressure vessel standards or to show ''a level of safety greater than or equal to'' that of the applicable standard. Thus, while used for its superconducting properties, niobium ends up being treated as a low-temperature pressure vessel material. Niobium material is not a code listed material and therefore requires the designer to understand the mechanical properties for material used in each pressure vessel fabrication; compliance with pressure vessel codes therefore becomes a problem. This report summarizes the approaches that various institutions have taken in order to bring superconducting RF cryomodules into compliance with pressure vessel codes. In Japan, Germany, and the U.S., institutions building superconducting RF cavities integrated in helium vessels or procuring them from vendors have had to deal with pressure vessel requirements being applied to SRF vessels, including the niobium and niobium-titanium components of the vessels. While niobium is not an approved pressure vessel material, data from tests of material samples provide information to set allowable stresses. By means of procedures which include adherence to code welding procedures, maintaining material and fabrication records, and detailed analyses of peak stresses in the vessels, or treatment of the vacuum vessel as the pressure boundary, research laboratories around the world have found methods to demonstrate and document a level of safety equivalent to the applicable pressure vessel codes.

43 PARTICLE ACCELERATORS↗

International Linear Collider (ILC): A Technical Progress Report

In 2003, more than 2,700 scientists from around the world signed a published statement Understanding Matter, Energy, Space and Time: the Case for the Linear Collider [1-1]. The statement made clear the undisputed worldwide consensus that the next energy frontier machine after the Large Hadron Collider (LHC) should be an electron-positron linear collider with an initial centre-of-mass energy reach of 500 gigaelectronvolts (GeV), upgradable to 1 teraelectronvolt (TeV). In the same year, the International Committee for Future Accelerators (ICFA) commissioned the International Technology Review Panel (ITRP) to select from the then competing acceleration technologies a single technology that would be the basis for an international design effort towards a truly global project. The following year, 2004, the ITRP recommended to ICFA that the 1.3-gigahertz superconducting radiofrequency (SCRF) technology developed by the TESLA collaboration [1-2] should form the basis for the design of the International Linear Collider (ILC).

43 PARTICLE ACCELERATORS↗

Observation of Intravascular Changes of Superabsorbent Polymer Microsphere (SAP-MS) with Monochromatic X-Ray Imaging

This study was designed to evaluate the intravascular transformation behavior of superabsorbent polymer microsphere (SAP-MS) in vivo macroscopically by using monochromatic X-ray imaging and to quantitatively compare the expansion rate of SAP-MS among different kinds of mixtures. Fifteen rabbits were used for our study and transcatheter arterial embolization (TAE) was performed for their auricular arteries using monochromatic X-ray imaging. We used three kinds of SAP-MS (particle diameter 100-150 {mu}m) mixture as embolic spherical particles: SAP-MS(H) absorbed with sodium meglumine ioxaglate (Hexabrix 320), SAP-MS(V) absorbed with isosmolar contrast medium (Visipaque 270), and SAP-MS(S) absorbed with 0.9% sodium saline. The initial volume of SAP-MS particles just after TAE and its final volume 10 minutes after TAE in the vessel were measured to calculate the expansion rate (ER) (n = 30). Intravascular behavior of SAP-MS particles was clearly observed in real time at monochromatic X-ray imaging. Averaged initial volumes of SAP-MS (H) (1.24 x 10{sup 7} {mu}m{sup 3}) were significantly smaller (p < 0.001) than those of SAP-MS (V) (5.99 x 10{sup 7} {mu}m{sup 3}) and SAP-MS (S) (5.85 x 10{sup 7} {mu}m{sup 3}). Averaged final volumes of SAP-MS (H) were significantly larger than averaged initial volumes (4.41 x 10{sup 7} {mu}m{sup 3} vs. 1.24 x 10{sup 7} {mu}m{sup 3}; p < 0.0001, ER = 3.55). There were no significant difference between averaged final volumes and averaged initial volumes of SAP-MS (V) and SAP-MS (S). SAP-MS (H), which first travels distally, reaches to small arteries, and then expands to adapt to the vessel lumen, is an effective particle as an embolic agent, causing effective embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determinants of Local Progression After Computed Tomography-Guided Percutaneous Radiofrequency Ablation for Unresectable Lung Tumors: 9-Year Experience in a Single Institution

The purpose of this study was to retrospectively determine the local control rate and contributing factors to local progression after computed tomography (CT)-guided radiofrequency ablation (RFA) for unresectable lung tumor. This study included 138 lung tumors in 72 patients (56 men and 16 women; age 70.0 {+-} 11.6 years (range 31-94); mean tumor size 2.1 {+-} 1.2 cm [range 0.2-9]) who underwent lung RFA between June 2000 and May 2009. Mean follow-up periods for patients and tumors were 14 and 12 months, respectively. The local progression-free rate and survival rate were calculated to determine the contributing factors to local progression. During follow-up, 44 of 138 (32%) lung tumors showed local progression. The 1-, 2-, 3-, and 5-year overall local control rates were 61, 57, 57, and 38%, respectively. The risk factors for local progression were age ({>=}70 years), tumor size ({>=}2 cm), sex (male), and no achievement of roll-off during RFA (P < 0.05). Multivariate analysis identified tumor size {>=}2 cm as the only independent factor for local progression (P = 0.003). For tumors <2 cm, 17 of 68 (25%) showed local progression, and the 1-, 2-, and 3-year overall local control rates were 77, 73, and 73%, respectively. Multivariate analysis identified that age {>=}70 years was an independent determinant of local progression for tumors <2 cm in diameter (P = 0.011). The present study showed that 32% of lung tumors developed local progression after CT-guided RFA. The significant risk factor for local progression after RFA for lung tumors was tumor size {>=}2 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design of a High Field Nb3Al Common Coil Magnet

A high field Nb{sub 3}Al common coil magnet is under development as an R&D of 'Advanced Superconducting Magnets for the LHC Luminosity Upgrade', in the framework of the CERN-KEK cooperation program. The goal of this research is to demonstrate the feasibility of high field magnet wound with Nb{sub 3}Al cable. The common coil approach and the shell-based structure were adopted in the design of this magnet. Besides three Nb{sub 3}Al coils, two Nb{sub 3}Sn coils were included to increase the peak field of the whole magnet. The two types of coils were designed with different straight lengths to reduce the peak field of the Nb{sub 3}Sn coils. The peak fields of the Nb{sub 3}Al and Nb{sub 3}Sn coils are 13.1 T and 11.8 T respectively. An aluminum shell together with four aluminum rods applies stress to the coils to overcome the Lorenz force during excitation. Two different support structures for the superconducting coils were introduced in this paper. The development status is also presented.

43 PARTICLE ACCELERATORS↗

Antimatter and Dark Matter Search in Space: BESS-Polar Results

The apex of the Balloon-borne Experiment with a Superconducting Spectrometer program was reached with the Antarctic flight of BESS-Polar II, during the 2007-2008 Austral Summer, that obtained 24.5 days of data on over 4.7 billion cosmic-ray events. The US-Japan BESS Collaboration uses elementary particle measurements to study the early Universe and provides fundamental data on the spectra of light cosmic-ray elements and isotopes. BESS measures the energy spectra of cosmic-ray antiprotons to investigate signatures of possible exotic sources, such as dark-matter candidates, and searches for heavier anti-nuclei that might reach Earth from antimatter domains formed during symmetry breaking processes in the early Universe. Since 1993, BESS has carried out eleven high-latitude balloon flights, two of long duration, that together have defined the study of antiprotons below about 4 GeV, provided standard references for light element and isotope spectra, and set the most sensitive limits on the existence of anti-deuterons and anti-helium, The BESS-Polar II flight took place at Solar Minimum, when the sensitivity of the low-energy antiproton measurements to a primary source is greatest. The rich BESS-Polar II dataset more than doubles the combined data from all earlier BESS flights and has 10-20 times the statistics of BESS data from the previous Solar Minimum. Here, we summarize the scientific results of BESS program, focusing on the results obtained using data from the long-duration flights of BESS-Polar I (2004) and BESS-Polar II.

Mitchell, John W.↗

The BESS Search for Cosmic-Ray Antiproton Origins and for Cosmological Antimatter

The apex of the Balloon-borne Experiment with a Superconducting Spectrometer (BESS) program was reached with the Antarctic flight of BESS-Polar II, during the 2007-2008 Austral Summer, that obtained 24.5 days of data on over 4.7 billion cosmic-ray events. The US-Japan BESS Collaboration uses elementary particle measurements to study the early Universe and provides fundamental data on the spectra of light cosmic-ray elements and isotopes. BESS measures the energy spectra of cosmic-ray antiprotons to investigate signatures of possible exotic sources, such as dark-matter candidates, and searches for heavier antinuclei that might reach Earth from antimatter domains formed during symmetry breaking processes in the early Universe. Since 1993, BESS has carried out eleven high-latitude balloon flights, two of long duration, that together have defined the study of antiprotons below about 4 GeV, provided standard references for light element and isotope spectra, and set the most sensitive limits on the existence of antideuterons and antihelium. The BESS-Polar II flight took place at Solar Minimum, when the sensitivity of the low-energy antiproton measurements to a primary source is greatest. The rich BESS-Polar II dataset more than doubles the combined data from all earlier BESS flights and has 10-20 times the statistics of BESS data from the previous Solar Minimum. Here, we summarize the scientific results of BESS program, focusing on the results obtained using data from the long-duration flights of BESS-Polar I (2004) and BESS-Polar II.

Mitchell, John↗