Search NASA⌕ Search

Engineering topics

Yamamoto, S.

Publications and source records attributed to Yamamoto, S..

At least 19 records

Analysis of the ECH effect on EPM/AE stability in Heliotron J plasma using a Landau closure model

The aim of the present study is to analyze the effect of the electron cyclotron heating (ECH) on the linear stability of Alfvén eigenmodes (AEs) and energetic particle modes (EPMs) triggered by energetic ions in Heliotron J plasma. The analysis is performed using the FAR3d code that solves a reduced MHD model to describe the thermal plasma coupled with a gyrofluid model for the energetic particle (EP) species. The simulations reproduce the AE/EPM stability trends observed in the experiments as the electron temperature (T e ) increases, modifying the thermal plasma β, EP β and EP slowing-down time. Particularly, the $n/m = 1/2$ EPM and $2/4$ Global AE are stabilized in the low-bumpiness (LB) configuration due to an enhancement of the continuum, finite Larmor radius and e-i Landau damping effects as the thermal β increases. On the other hand, a larger ECH injection power cannot stabilize the AE/EPM in medium-bumpiness and high-bumpiness (HB) configurations because the damping effects are weaker compared to the LB case, unable to balance the further destabilization induced by an enhanced EP resonance as the EP slowing-down time and EP β increases with T e .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge-ordered state satisfying the Anderson condition in LiRh 2 O 4 arising from local dimer order

Here we report on the charge-ordered structure of LiRh 2 O 4 arising below the metal-insulator transition at 170 K. Structural studies using synchrotron x rays have revealed that the charge-ordered states of Rh 3+ and Rh 4+ with dimerization are realized in the low-temperature phase below 170 K. Although the low-temperature ground state resembles that of CuIr 2 S 4 , a charge-ordering pattern satisfying the Anderson condition is realized in LiRh 2 O 4 . Based on structural information such as the short-range order of dimers appearing above the transition temperature and the weakening of the correlation between rhodium one-dimensional chains appearing in the crystal structure, we argue that the Coulomb interaction plays an important role in determining the charge-ordering patterns.

36 MATERIALS SCIENCE↗

Modeling of the ECCD injection effect on the Heliotron J and LHD plasma stability

The aim of the study is to analyze the stability of the energetic particle modes (EPM) and Alfven Eigenmodes (AE) in Helitron J and LHD plasma if the electron cyclotron current drive (ECCD) is applied. Additionally, the analysis is performed using the code FAR3d that solves the reduced MHD equations describing the linear evolution of the poloidal flux and the toroidal component of the vorticity in a full 3D system, coupled with equations of density and parallel velocity moments for the energetic particle (EP) species, including the effect of the acoustic modes. The Landau damping and resonant destabilization effects are added via the closure relation. The simulation results show that the n = 1 EPM and n = 2 global AE (GAE) in Heliotron J plasma can be stabilized if the magnetic shear is enhanced at the plasma periphery by an increase (co-ECCD injection) or decrease (ctr-ECCD injection) of the rotational transform at the magnetic axis ($\rlap{-} \iota_{0}$). In the ctr-ECCD simulations, the EPM/AE growth rate decreases only below a given $\rlap{-} \iota_{0}$, similar to the ECCD intensity threshold observed in the experiments. In addition, ctr-ECCD simulations show an enhancement of the continuum damping. The simulations of the LHD discharges with ctr-ECCD injection indicate the stabilization of the n = 1 EPM, n = 2 toroidal AE (TAE) and n = 3 TAE, caused by an enhancement of the continuum damping in the inner plasma leading to a higher EP β threshold with respect to the co- and no-ECCD simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of a beam-driven low-frequency mode in Heliotron J

A low-frequency electromagnetic mode (LF-mode) has been observed in a stellarator/heliotron device, Heliotron J. The LF-mode is observed only in neutral beam heated plasmas with a co-current, which increases the rotational transform. The observed LF-mode peaks at rho = 0.86–0.91, where rho = r/a is the normalized minor radius. The LF-mode propagates in the ion diamagnetic drift direction, and the poloidal mode number is m ~ 6–8, determined with a combination of Mirnov coil arrays and 2D fast camera measurement. A high m number induces significant Doppler shift from the background ion flow. The frequency is corrected with both E × B rotation and the ion diamagnetic flow. The corrected frequency is almost consistent with the beta-induced Alfvén eigenmode gap evaluated with the STELLGAP code, although very close to the accumulation point. The mode could also be a global Alfvén eigenmode.

BAE↗

Development of beam emission spectroscopy for turbulence transport study in Heliotron J

This paper describes the development study of the beam emission spectroscopy (BES) for the turbulent transport study in Heliotron J. Modification of the sightlines (10 × 4 for edge and 10 × 2 for edge) enables us to obtain 2-dimensional BES imaging. The cooling effect on the reduction in the electrical noise of avalanche photodiode (APD) assembly has been investigated using a refrigerant cooling system. When the temperature of the APD element has set to be −20 °C, the electrical noise can be reduced more than 50%. The measurement error of the phase difference in the case of low signal level has been tested by two light-emitting diode lamps. The APD cooling has an effect to improve the measurement error at the low signal level of APD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neoclassical parallel flow calculation in the presence of external parallel momentum sources in Heliotron J

A moment approach to calculate neoclassical transport in non-axisymmetric torus plasmas composed of multiple ion species is extended to include the external parallel momentum sources due to unbalanced tangential neutral beam injections (NBIs). The momentum sources that are included in the parallel momentum balance are calculated from the collision operators of background particles with fast ions. This method is applied for the clarification of the physical mechanism of the neoclassical parallel ion flows and the multi-ion species effect on them in Heliotron J NBI plasmas. It is found that parallel ion flow can be determined by the balance between the parallel viscosity and the external momentum source in the region where the external source is much larger than the thermodynamic force driven source in the collisional plasmas. This is because the friction between C{sup 6+} and D{sup +} prevents a large difference between C{sup 6+} and D{sup +} flow velocities in such plasmas. The C{sup 6+} flow velocities, which are measured by the charge exchange recombination spectroscopy system, are numerically evaluated with this method. It is shown that the experimentally measured C{sup 6+} impurity flow velocities do not contradict clearly with the neoclassical estimations, and the dependence of parallel flow velocities on the magnetic field ripples is consistent in both results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for $n-\bar{n}$ oscillation in Super-Kamiokande

In this study, a search for neutron-antineutron ($n-\bar{n}$) oscillation was undertaken in Super-Kamiokande using the 1489 live-day or 2.45×10 34 neutron-year exposure data. This process violates both baryon and baryon minus lepton numbers by an absolute value of two units and is predicted by a large class of hypothetical models where the seesaw mechanism is incorporated to explain the observed tiny neutrino masses and the matter-antimatter asymmetry in the Universe. No evidence for $n-\bar{n}$ oscillation was found, the lower limit of the lifetime for neutrons bound in 16 O, in an analysis that included all of the significant sources of experimental uncertainties, was determined to be 1.9×10 32 years at the 90% confidence level. The corresponding lower limit for the oscillation time of free neutrons was calculated to be 2.7×10 8 s using a theoretical value of the nuclear suppression factor of 0.517 × 10 23 s -1 and its uncertainty.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First measurement of time evolution of electron temperature profiles with Nd:YAG Thomson scattering system on Heliotron J

A Nd:YAG Thomson scattering system has been developed for Heliotron J. The system consists of two 550 mJ 50 Hz lasers, large collection optics, and 25 radial channel (∼1 cm spatial resolution) interference polychromators. This measurement system achieves a S/N ratio of ∼50 for low-density plasma (n{sub e} ∼ 0.5 × 10{sup 19} m{sup −3}). A time evolution of electron temperature profiles was measured with this system for a high-intensity gas-puff (HIGP) fueling neutral-beam-injection plasma. The peripheral temperature of the higher-density phase after HIGP recovers to the low-density pre-HIGP level, suggesting that improving particle transport in the HIGP plasma may be possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly time-resolved evaluation technique of instantaneous amplitude and phase difference using analytic signals for multi-channel diagnostics

A fluctuation analysis technique using analytic signals is proposed. Analytic signals are suitable to characterize a single mode with time-dependent amplitude and frequency, such as an MHD mode observed in fusion plasmas since the technique can evaluate amplitude and frequency at a specific moment without limitations of temporal and frequency resolutions, which is problematic in Fourier-based analyses. Moreover, a concept of instantaneous phase difference is newly introduced, and error of the evaluated phase difference and its error reduction techniques using conditional/ensemble averaging are discussed. These techniques are applied to experimental data of the beam emission spectroscopic measurement in the Heliotron J device, which demonstrates that the technique can describe nonlinear evolution of MHD instabilities. This technique is widely applicable to other diagnostics having necessity to evaluate phase difference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-hole recombination on ZnO(0001) single-crystal surface studied by time-resolved soft X-ray photoelectron spectroscopy

Time-resolved soft X-ray photoelectron spectroscopy (PES) experiments were performed with time scales from picoseconds to nanoseconds to trace relaxation of surface photovoltage on the ZnO(0001) single crystal surface in real time. The band diagram of the surface has been obtained numerically using PES data, showing a depletion layer which extends to 1 μm. Temporal evolution of the photovoltage effect is well explained by a recombination process of a thermionic model, giving the photoexcited carrier lifetime of about 1 ps at the surface under the flat band condition. This lifetime agrees with a temporal range reported by the previous time-resolved optical experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel electron density reconstruction method for asymmetrical toroidal plasmas

A novel reconstruction method is developed for acquiring the electron density profile from multi-channel interferometric measurements of strongly asymmetrical toroidal plasmas. It is based on a regularization technique, and a generalized cross-validation function is used to optimize the regularization parameter with the aid of singular value decomposition. The feasibility of method could be testified by simulated measurements based on a magnetic configuration of the flexible helical-axis heliotron device, Heliotron J, which has an asymmetrical poloidal cross section. And the successful reconstruction makes possible to construct a multi-channel Far-infrared laser interferometry on this device. The advantages of this method are demonstrated by comparison with a conventional method. The factors which may affect the accuracy of the results are investigated, and an error analysis is carried out. Based on the obtained results, the proposed method is highly promising for accurately reconstructing the electron density in the asymmetrical toroidal plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observing hot carrier distribution in an n-type epitaxial graphene on a SiC substrate

Hot carrier dynamics in the Dirac band of n-type epitaxial graphene on a SiC substrate were traced in real time using femtosecond-time-resolved photoemission spectroscopy. The spectral evolution directly reflects the energetically linear density of states superimposed with a Fermi–Dirac distribution. The relaxation time is governed by the internal energy dissipation of electron–electron scattering, and the observed electronic temperature indicates cascade carrier multiplication.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of supersonic molecular-beam injection on edge fluctuation and particle transport in Heliotron J

Edge fluctuation in a supersonic molecular-beam injection (SMBI) fueled plasma has been measured using an electrostatic probe array. After SMBI, the plasma stored energy (W{sub p}) temporarily decreased then started to increase. The local plasma fluctuation and fluctuation induced particle transport before and after SMBI have been analyzed. In a short duration (∼4 ms) just after SMBI, the density fluctuation of broad-band low frequency increased, and the probability density function (PDF) changed from a nearly Gaussian to a positively skewed non-Gaussian one. This suggests that intermittent structures were produced due to SMBI. Also the fluctuation induced particle transport was greatly enhanced during this short duration. About 4 ms after SMBI, the low frequency broad-band density fluctuation decreased, and the PDF returned to a nearly Gaussian shape. Also the fluctuation induced particle transport was reduced. Compared with conventional gas puff, W{sub p} degradation window is very short due to the short injection period of SMBI. After this short degradation window, fluctuation induced particle transport was reduced and W{sub p} started the climbing phase. Therefore, the short period of the influence to the edge fluctuation might be an advantage of this novel fueling technique. On the other hand, although their roles are not identified at present, coherent MHD modes are also suppressed as well by the application of SMBI. These MHD modes are thought to be de-exited due to a sudden change of the edge density and/or excitation conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density fluctuation measurements using beam emission spectroscopy on Heliotron J

This paper describes the measurement of the density fluctuation using beam emission spectroscopy in Heliotron J, having the non-symmetrical helical-magnetic-axis configuration. In order to optimize the sightlines, the numerical calculations are carried out to estimate the spatial resolution and the observation location. When a tangential neutral beam is used as diagnostic one, suitable sightlines from the newly installed diagnostic port are selected whose spatial resolution {Delta}{rho} is less than {+-}0.07 over the entire plasma region. Modification of the interference filter and the detection systems enables us to measure the radial profile of the density fluctuation. Each of the three coherent modes due to the fast-ion-driven magnetohydrodynamic instabilities has different radial structure of the density fluctuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a pixelated GSO gamma camera system with tungsten parallel hole collimator for single photon imaging

Purpose: In small animal imaging using a single photon emitting radionuclide, a high resolution gamma camera is required. Recently, position sensitive photomultiplier tubes (PSPMTs) with high quantum efficiency have been developed. By combining these with nonhygroscopic scintillators with a relatively low light output, a high resolution gamma camera can become useful for low energy gamma photons. Therefore, the authors developed a gamma camera by combining a pixelated Ce-doped Gd{sub 2}SiO{sub 5} (GSO) block with a high quantum efficiency PSPMT. Methods: GSO was selected for the scintillator, because it is not hygroscopic and does not contain any natural radioactivity. An array of 1.9 mm x 1.9 mm x 7 mm individual GSO crystal elements was constructed. These GSOs were combined with a 0.1-mm thick reflector to form a 22 x 22 matrix and optically coupled to a high quantum efficiency PSPMT (H8500C-100 MOD8). The GSO gamma camera was encased in a tungsten gamma-ray shield with tungsten pixelated parallel hole collimator, and the basic performance was measured for Co-57 gamma photons (122 keV). Results: In a two-dimensional position histogram, all pixels were clearly resolved. The energy resolution was {approx}15% FWHM. With the 20-mm thick tungsten pixelated collimator, the spatial resolution was 4.4-mm FWHM 40 mm from the collimator surface, and the sensitivity was {approx}0.05%. Phantom and small animal images were successfully obtained with our developed gamma camera. Conclusions: These results confirmed that the developed pixelated GSO gamma camera has potential as an effective instrument for low energy gamma photon imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗