Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

36 MATERIALS SCIENCE↗

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in X-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard X-ray TESs to measure the absolute energies of muonic-argon (R-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. Here, we achieved similar to 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

A two-dimensional resistor network model for transition-edge sensors with normal metal features

Transition-edge sensors (TESs) can be used in high-resolution photon detection, exploiting the steep slope of the resistance in the superconducting-to-normal transition edge. Normal metal bars on the TES film are commonly used to engineer its transition shape, namely the dependence of resistance on temperature and current. This problem has been studied in one dimension, but until now, there have been no predictive models of the influence of two-dimensional (2-D) normal metal features on the TES transition shape. Here, we approach this problem by treating the TES as a 2-D network of resistors, the values of which are based on the two-fluid model. We introduce a study of the behavior of devices with different 2-D geometric features. Our 2-D network model is capable of predicting how typical TES geometry parameters, such as number of bars, bar spacing, and overall dimensions, influence device behavior and thus is a powerful tool to guide the engineering of new TES devices.

2-D resistors network↗

Modelling a Transition-Edge Sensor X-Ray Microcalorimeter Linear Array for Compton Profile Measurements and Energy Dispersive Diffraction

Transition-edge sensors (TES) are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically been designed and used for spectroscopic applications. In this work, we present a design optimization for a TES X-ray microcalorimeter array for high-energy scattering and diffraction measurements. Specifically, Compton scattering provides information about the electron momentum distribution, while energy dispersive diffraction provides structural information about dense engineering materials. Compton scattering and energy dispersive diffraction experiments must be conducted in the very hard X-ray regime (~100 keV), demanding a high X-ray stopping power in the detector; therefore, an absorber with a large heat capacity is needed in conjunction with the TES. In addition, both applications would benefit from an array composed of parallel strips. We propose a design for a TES X-ray microcalorimeter optimized for such applications. In particular, we model the longitudinal position dependence due to the finite thermal diffusion time in the absorber.

47 OTHER INSTRUMENTATION↗

Microstructure Analysis of Bismuth Absorbers for Transition-Edge Sensor X-ray Microcalorimeters

Given its large X-ray stopping power and low specific heat capacity, bismuth (Bi) is a promising absorber material for X-ray microcalorimeters and has been used with transition-edge sensors (TESs) in the past. However, distinct X-ray spectral features have been observed in TESs with Bi absorbers deposited with different techniques. Evaporated Bi absorbers are widely reported to have non-Gaussian low-energy tails, while electroplated ones do not show this feature. In this study, we fabricated Bi absorbers with these two methods and performed microstructure analysis using scanning electron microscopy and X-ray diffraction microscopy. The two types of material showed the same crystallographic structure, but the grain size of the electroplated Bi was about 40 times larger than that of the evaporated Bi. This distinction in grain size is likely to be the cause of their different spectral responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗