Search NASA⌕ Search

Engineering topics

Yan, Feng

Publications and source records attributed to Yan, Feng.

50 records · Page 3

Errors in particle tracking velocimetry with high-speed cameras

Velocity errors in particle tracking velocimetry (PTV) are studied. When using high-speed video cameras, the velocity error may increase at a high camera frame rate. This increase in velocity error is due to particle-position uncertainty, which is one of the two sources of velocity errors studied here. The other source of error is particle acceleration, which has the opposite trend of diminishing at higher frame rates. Both kinds of errors can propagate into quantities calculated from velocity, such as the kinetic temperature of particles or correlation functions. As demonstrated in a dusty plasma experiment, the kinetic temperature of particles has no unique value when measured using PTV, but depends on the sampling time interval or frame rate. It is also shown that an artifact appears in an autocorrelation function computed from particle positions and velocities, and it becomes more severe when a small sampling-time interval is used. Schemes to reduce these errors are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying anomalous diffusion and melting in dusty plasmas

Anomalous diffusion in liquids and the solid-liquid phase transition (melting) are studied in two-dimensional Yukawa systems. The self-intermediate scattering function (self-ISF), calculated from simulation data, exhibits a temporal decay, or relaxation, with a characteristic relaxation time. This decay is found to be useful for distinguishing normal and anomalous diffusion in a liquid, and for identifying the solid-liquid phase transition. For liquids, a scaling of the relaxation time with length scale is found. For the solid-liquid phase transition, the shape of the self-ISF curve is found to be a sensitive indicator of phase. Friction has a significant effect on the timing of relaxation, but not the melting point.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mode Coupling for Phonons in a Single-Layer Dusty Plasma Crystal

New modes in a dusty plasma result from coupling of differently polarized phonons. A single horizontal layer of charged microparticles, confined so that vertical as well as horizontal motions are possible, usually exhibits three modes. An experiment shows that mode coupling leads to a new hybrid mode and another new mode. Coupling also leads to a recently reported hybrid mode and nondispersive mode, shown here to occur in an unmelted lattice. A linear theory based on ion wakes is able to predict some, but not all, of these modes. Other multiphase systems could exhibit similar mode coupling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Viscoelasticity of 2D Liquids Quantified in a Dusty Plasma Experiment

The viscoelasticity of two-dimensional liquids is quantified in an experiment using a dusty plasma. An experimental method is demonstrated for measuring the wave-number-dependent viscosity {eta}(k), which is a quantitative indicator of viscoelasticity. Using an expression generalized here to include friction, {eta}(k) is computed from the transverse current autocorrelation function, which is found by tracking random particle motion. The transverse current autocorrelation function exhibits an oscillation that is a signature of elastic contributions to viscoelasticity. Simulations of a Yukawa liquid are consistent with the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of Shear-Induced Melting in a Dusty Plasma

The spatiotemporal development of melting is studied experimentally in a 2D dusty plasma suspension. Starting with an ordered lattice, and then suddenly applying localized shear, a pair of counterpropagating flow regions develop. A transition between two melting stages is observed before a steady state is reached. Melting spreads with a front that propagates at the transverse sound speed. Unexpectedly, coherent longitudinal waves are excited in the flow region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The blood-brain barrier penetration and distribution of PEGylated fluorescein-doped magnetic silica nanoparticles in rat brain

PEGylated PAMAM conjugated fluorescein-doped magnetic silica nanoparticles (PEGylated PFMSNs) have been synthesized for evaluating their ability across the blood-brain barrier (BBB) and distribution in rat brain. The obtained nanoparticles were characterized by transmission electron microscopy (TEM), thermal gravimetry analyses (TGA), zeta potential ({zeta}-potential) titration, and X-ray photoelectron spectroscopy (XPS). The BBB penetration and distribution of PEGylated PFMSNs and FMSNs in rat brain were investigated not only at the cellular level with Confocal laser scanning microscopy (CLSM), but also at the subcellular level with transmission electron microscopy (TEM). The results provide direct evidents that PEGylated PFMSNs could penetrate the BBB and spread into the brain parenchyma.

60 APPLIED LIFE SCIENCES↗

AlGaN Ultraviolet Detectors for Dual-Band UV Detection

This innovation comprises technology that has the ability to measure at least two ultraviolet (UV) bands using one detector without relying on any external optical filters. This allows users to build a miniature UVA and UVB monitor, as well as to develop compact, multicolor imaging technologies for flame temperature sensing, air-quality control, and terrestrial/counter-camouflage/biosensing applications.

Miko, Laddawan↗

Patterns of Retropharyngeal Node Metastasis in Nasopharyngeal Carcinoma

Purpose: To explore the pattern of metastasis to retropharyngeal lymph nodes (RLN) and its relationship with tumor range in nasopharyngeal carcinoma (NPC) patients by using magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 618 NPC patients were reviewed. Nodes were classified as metastatic on the basis of size criteria, the presence of nodal necrosis, and extracapsular spread. Results: A total of 597 involved RLN were detected in 392 patients (63.4%). The sites of RLN metastasis included occipital bone, 37 (6.2%); first cervical vertebra (C1), 453 (75.9%); second cervical vertebra (C2), 104 (17.4%); and third cervical vertebra (C3), 3 (0.5%). The incidence of RLN involvement was less than that of Level IIb node involvement (72.2% vs. 86.5%) in 543 patients with lymphadenopathy. The incidence of RLN metastasis was significantly higher in cases of parapharyngeal space invasion or involvement of Level II, Level III, Level IV, and/or Level V nodes and significantly lower in N0 and Stage I disease. Conversely, the incidence of RLN metastasis did not differ significantly among T1, 2, 3, and 4 disease or among Stage II, III, and IV disease. Conclusions: Level IIb nodes, rather than RLN, seem to be the first-echelon nodes in NPC. The incidence of RLN metastasis decreases steadily from level C1 to level C3. Retropharyngeal lymph node metastasis correlates well with involvement of the parapharyngeal space and metastases to Level II, III, IV, and/or V nodes but not with T stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bias Selectable Dual Band AlGaN Ultra-violet Detectors

Bias selectable dual band AlGaN ultra-violet (UV) detectors, which can separate UV-A and UV-B using one detector in the same pixel by bias switching, have been designed, fabricated and characterized. A two-terminal n-p-n photo-transistor-like structure was used. When a forward bias is applied between the top electrode and the bottom electrode, the detectors can successfully detect W-A and reject UV-B. Under reverse bias, they can detect UV-B and reject UV-A. The proof of concept design shows that it is feasible to fabricate high performance dual-band UV detectors based on the current AlGaN material growth and fabrication technologies.

Yan, Feng↗

SiC-based Photo-detectors for UV, VUV, EUV and Soft X-ray Detection

A viewgraph presentation describing an ideal Silicon Carbide detector for ultraviolet, vacuum ultraviolet, extreme ultraviolet and soft x-ray detection is shown. The topics include: 1) An ideal photo-detector; 2) Dark current density of SiC photodiodes at room temperature; 3) Dark current in SiC detectors; 4) Resistive and capacitive feedback trans-impedance amplifier; 5) Avalanche gain; 6) Excess noise; 7) SNR in single photon counting mode; 8) Structure of SiC single photon counting APD and testing structure; 9) Single photon counting waveform and testing circuit; 10) Amplitude of SiC single photon counter; 11) Dark count of SiC APD photon counters; 12) Temperature-dependence of dark count rate; 13) Reduce the dark count rate by reducing the breakdown electric field; 14) Spectrum range for SiC detectors; 15) QE curves of Pt/4H-SiC photodiodes; 16) QE curve of SiC; 17) QE curves of SiC photodiode vs. penetration depth; 18) Visible rejection of SiC photodiodes; 19) Advantages of SiC photodiodes; 20) Competitors of SiC detectors; 21) Extraterrestrial solar spectra; 22) Visible-blind EUV detection; 23) Terrestrial solar spectra; and 24) Less than 1KeV soft x-ray detection.

Yan, Feng↗

Demonstration of the First 4H-SiC EUV Detector with Large Detection Area

Ultraviolet (UV) and Extreme Ultraviolet (EUV) detectors are very attractive in astronomy, photolithography and biochemical applications. For EUV applications, most of the semiconductor detectors based on PN or PIN structures suffer from the very short penetration depth. Most of the carries are absorbed at the surface and recombined there due to the high surface recombination before reach the depletion region, resulting very low quantum efficiency. On the other hand, for Schottky structures, the active region starts from the surface and carriers generated from the surface can be efficiently collected. 4H-Sic has a bandgap of 3.26eV and is immune to visible light background noise. Also, 4H-Sic detectors usually have very good radiation hardness and very low noise, which is very important for space applications where the signal is very weak. The E W photodiodes presented in this paper are based on Schottky structures. Platinum (Pt) and Nickel (Ni) are selected as the Schottky contact metals, which have the highest electron work functions (5.65eV and 5.15eV, respectively) among all the known metals on 4H-Sic.

Xin, Xiaobin↗

Development of Ultra-High Sensivity Silicon Carbide Detectors

A variety of silicon carbide (SiC) detectors have been developed to study the sensitivity of SiC ultraviolet (UV) detectors, including Schottky photodiodes, p-i-n photodiodes, avalanche photodiodes (APDs), and single photon-counting APDs. Due to the very wide bandgap and thus extremely low leakage current, Sic photo-detectors showed excellent sensitivity. The specific detectivity, D*, of SiC photodiodes are orders of magnitude higher than that of their competitors, such as Si photodiodes, and comparable to the D* of photomultiplier tubes (PMTs). To pursue the ultimate detection sensitivity, SiC APDs and single photon-counting avalanche diodes (SPADs) have also been fabricated. By operating the SiC APDs at a linear mode gain over 10(exp 6), SPADs in UV have been demonstrated. SiC UV detectors have great potential for use in solar blind UV detection and biosensing. Moreover, SiC detectors have excellent radiation hardness and high temperature tolerance which makes them ideal for extreme environment applications such as in space or on the surface of the Moon or Mars.

Yan, Feng↗

4H-SiC UV Photo Detector with Large Area and Very High Specific Detectivity

Pt/4H-SiC Schottky photodiodes have been fabricated with the device areas up to 1 sq cm. The I-V characteristics and photo-response spectra have been measured and analyzed. For a 5 mm x 5 mm area device leakage current of 1 x 10(exp 15)A at zero bias and 1.2 x 10(exp 14)A at -IV have been established. The quantum efficiency is over 30% from 240nm to 320nm. The specific detectivity, D(sup *), has been calculated from the directly measured leakage current and quantum efficiency data and are shown to be higher than 10(exp 15) cmHz(sup 1/2)/W from 210nm to 350nm with a peak D(sup *) of 3.6 x 10(exp 15)cmH(sup 1/2)/W at 300nm.

Yan, Feng↗