Search NASA⌕ Search

Engineering topics

Yan, Yu

Publications and source records attributed to Yan, Yu.

34 records · Page 2

In Operando Visualization of the Electrochemical Formation of Liquid Polybromide Microdroplets

Abstract Zinc–bromine flow batteries are promising for stationary energy storage, and bromine‐complexing agents have been used to form phase‐separated liquid polybromide products. However, an understanding of the dynamics of polybromide nucleation is limited due to the beam sensitivity and complexity of polybromides. Here we report an in operando platform composed of dark‐field light microscopy and a transparent electrochemical cell to reveal the dynamics of polybromide formation in their native environment. Using our platform, we confirm and reveal the liquid nature, chemical composition, pinning effect (strong interaction with Pt), residual effect (residual charge products on the surface), self‐discharging, and over‐oxidation of the polybromide products. The results provide insights into the role of complexing agents and guide the future design of zinc–bromine flow batteries. Furthermore, our in operando platform can potentially be used to study sensitive species and phases in other electrochemical reactions.

Wu, Yutong↗

In Operando Visualization of the Electrochemical Formation of Liquid Polybromide Microdroplets

Zinc–bromine flow batteries are promising for stationary energy storage, and bromine-complexing agents have been used to form phase-separated liquid polybromide products. However, an understanding of the dynamics of polybromide nucleation is limited due to the beam sensitivity and complexity of polybromides. Here we report an in operando platform composed of dark-field light microscopy and a transparent electrochemical cell to reveal the dynamics of polybromide formation in their native environment. Using our platform, we confirm and reveal the liquid nature, chemical composition, pinning effect (strong interaction with Pt), residual effect (residual charge products on the surface), self-discharging, and over-oxidation of the polybromide products. Overall, the results provide insights into the role of complexing agents and guide the future design of zinc–bromine flow batteries. Furthermore, our in operando platform can potentially be used to study sensitive species and phases in other electrochemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic modeling for the initial stage of chromium passivation

The well-known anti-corrosive property of stainless steels is largely attributed to the addition of Cr, which can assist in forming an inert film on the corroding surface. To maximize the corrosion-resistant ability of Cr, a thorough study dealing with the passivation behaviors of this metal, including the structure and composition of the passive film as well as related reaction mechanisms, is required. In this work, continuous electrochemical adsorptions of OH-groups of water molecules onto Cr terraces in acid solutions are investigated using DFT methods. Different models with various surface conditions are applied. Passivation is found to begin in the active region, and a fully coated surface mainly with oxide is likely to be the starting point of the passive region. The measured limiting potentials are in reasonable agreement with passivation potentials observed via experiment.

58 GEOSCIENCES↗

MeWRKY20 and its interacting and activating autophagy-related protein 8 (MeATG8) regulate plant disease resistance in cassava

Highlights: • A systematic genome-wide of MeATGs is performed. • MeWRKY20 physically interacts with MeATG8a/8f/8h. • MeWRKY20 activates the transcription of MeATG8a. • MeATG8s and MeWRKY20 regulate defense response in cassava. As a highly conserved mechanism, autophagy is responsible for the transport of cytoplasmic constituents in the vacuoles or lysosomes. Moreover, autophagy is essential for plant development and various stress responses. In this study, 34 MeATGs were systematically identified in cassava, and their transcripts were commonly regulated by Xanthomonas axonopodis pv manihotis (Xam). Through transient expression in Nicotiana benthamiana, the subcellular locations of 4 MeATG8s were revealed. Notably, MeWRKY20 was identified as physical interacting protein of MeATG8a/8f/8h and upstream transcriptional activator of MeATG8a. Through virus-induced gene silencing (VIGS) in cassava, we found that MeATG8-silenced and MeWRKY20-silenced plants resulted in disease sensitive, with less callose depositions and lower autophagic activity. This study may facilitate our understanding of the upstream MeWRKY20 and underlying target as well as interacting proteins of MeATG8s in immune response. Taken together, MeWRKY20 and MeATG8a/8f/8h are essential for disease resistance against bacterial blight by forming various transcriptional modules and interacting complex in cassava.

60 APPLIED LIFE SCIENCES↗

A region-based segmentation method for ultrasound images in HIFU therapy

Purpose: Precisely and efficiently locating a tumor with less manual intervention in ultrasound-guided high-intensity focused ultrasound (HIFU) therapy is one of the keys to guaranteeing the therapeutic result and improving the efficiency of the treatment. The segmentation of ultrasound images has always been difficult due to the influences of speckle, acoustic shadows, and signal attenuation as well as the variety of tumor appearance. The quality of HIFU guidance images is even poorer than that of conventional diagnostic ultrasound images because the ultrasonic probe used for HIFU guidance usually obtains images without making contact with the patient’s body. Therefore, the segmentation becomes more difficult. To solve the segmentation problem of ultrasound guidance image in the treatment planning procedure for HIFU therapy, a novel region-based segmentation method for uterine fibroids in HIFU guidance images is proposed. Methods: Tumor partitioning in HIFU guidance image without manual intervention is achieved by a region-based split-and-merge framework. A new iterative multiple region growing algorithm is proposed to first split the image into homogenous regions (superpixels). The features extracted within these homogenous regions will be more stable than those extracted within the conventional neighborhood of a pixel. The split regions are then merged by a superpixel-based adaptive spectral clustering algorithm. To ensure the superpixels that belong to the same tumor can be clustered together in the merging process, a particular construction strategy for the similarity matrix is adopted for the spectral clustering, and the similarity matrix is constructed by taking advantage of a combination of specifically selected first-order and second-order texture features computed from the gray levels and the gray level co-occurrence matrixes, respectively. The tumor region is picked out automatically from the background regions by an algorithm according to a priori information about the tumor position, shape, and size. Additionally, an appropriate cluster number for spectral clustering can be determined by the same algorithm, thus the automatic segmentation of the tumor region is achieved. Results: To evaluate the performance of the proposed method, 50 uterine fibroid ultrasound images from different patients receiving HIFU therapy were segmented, and the obtained tumor contours were compared with those delineated by an experienced radiologist. For area-based evaluation results, the mean values of the true positive ratio, the false positive ratio, and the similarity were 94.42%, 4.71%, and 90.21%, respectively, and the corresponding standard deviations were 2.54%, 3.12%, and 3.50%, respectively. For distance-based evaluation results, the mean values of the normalized Hausdorff distance and the normalized mean absolute distance were 4.93% and 0.90%, respectively, and the corresponding standard deviations were 2.22% and 0.34%, respectively. The running time of the segmentation process was 12.9 s for a 318 × 333 (pixels) image. Conclusions: Experiments show that the proposed method can segment the tumor region accurately and efficiently with less manual intervention, which provides for the possibility of automatic segmentation and real-time guidance in HIFU therapy.

60 APPLIED LIFE SCIENCES↗

Mechanism of multi-defect induced ferromagnetism in undoped rutile TiO{sub 2}

Based on first-principles calculations, the coexistence of Ti vacancies (V{sub Ti}) and O vacancies (V{sub O}) is first considered to study the origin of the ferromagnetic ordering in undoped rutile TiO{sub 2}. The calculations show that V{sub O} can induce local magnetic moments in TiO{sub 2}, however, the ferromagnetic (FM) exchange interaction of two V{sub O} is not strong enough to induce room-temperature (RT) ferromagnetism on their own in undoped TiO{sub 2}. The FM coupling between two V{sub Ti} is about four times stronger than that between two V{sub O}. More importantly, the FM coupling between two V{sub Ti} is further enhanced after V{sub O} is introduced. Our results indicate that the electrons induced by V{sub O} mediate the long-range FM exchange interaction between two distant V{sub Ti}. This maybe the ferromagnetism mechanism in undoped TiO{sub 2}: V{sub Ti} produce local moments while the electrons induced by V{sub O} mediated the long-range FM exchange interaction. The results are in excellent agreement with the experimental evidences that V{sub O} alone cannot induce RT ferromagnetism while V{sub O} can promote the ferromagnetic ordering in undoped TiO{sub 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tuning magnetism of monolayer MoS{sub 2} by doping vacancy and applying strain

In view of important role of inducing and manipulating the magnetism in two-dimensional materials for the development of low-dimensional spintronic devices, the influences of strain on electronic structure and magnetic properties of commonly observed vacancies doped monolayer MoS{sub 2} are investigated using first-principles calculations. It is shown that unstrained V{sub S}, V{sub S2}, and V{sub MoS3} doped monolayer MoS{sub 2} systems are nonmagnetic, while the ground state of unstrained V{sub MoS6} doped system is magnetic and the magnetic moment is contributed mainly by six Mo atoms around V{sub MoS6}. In particular, tensile strain can induce magnetic moments in V{sub S}, V{sub S2}, and V{sub MoS3} doped monolayer MoS{sub 2} due to the breaking of Mo–Mo metallic bonds around the vacancies, while the magnetization induced by V{sub MoS6} can be effectively manipulated by equibiaxial strain due to the change of Mo–Mo metallic bonds around V{sub MoS6} under strains.

36 MATERIALS SCIENCE↗

Comparative dose evaluations between XVI and OBI cone beam CT systems using Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters

Purpose: To investigate the effect of energy (kVp) and filters (no filter, half Bowtie, and full Bowtie) on the dose response curves of the Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters (OSLDs) in CBCT dose fields. To measure surface and internal doses received during x-ray volume imager (XVI) (Version R4.5) and on board imager (OBI) (Version 1.5) CBCT imaging protocols using these two types of dosimeters. Methods: Gafchromic XRQA2 film and nanoDot OSLD dose response curves were generated at different kV imaging settings used by XVI (software version R4.5) and OBI (software version 1.5) CBCT systems. The settings for the XVI system were: 100 kVp/F0 (no filter), 120 kVp/F0, and 120 kVp/F1 (Bowtie filter), and for the OBI system were: 100 kVp/full fan, 125 kVp/full fan, and 125 kVp/half fan. XRQA2 film was calibrated in air to air kerma levels between 0 and 11 cGy and scanned using reflection scanning mode with the Epson Expression 10000 XL flat-bed document scanner. NanoDot OSLDs were calibrated on phantom to surface dose levels between 0 and 14 cGy and read using the inLight{sup TM} MicroStar reader. Both dosimeters were used to measure in field surface and internal doses in a male Alderson Rando Phantom. Results: Dose response curves of XRQA2 film and nanoDot OSLDs at different XVI and OBI CBCT settings were reported. For XVI system, the surface dose ranged between 0.02 cGy in head region during fast head and neck scan and 4.99 cGy in the chest region during symmetry scan. On the other hand, the internal dose ranged between 0.02 cGy in the head region during fast head and neck scan and 3.17 cGy in the chest region during chest M20 scan. The average (internal and external) dose ranged between 0.05 cGy in the head region during fast head and neck scan and 2.41 cGy in the chest region during chest M20 scan. For OBI system, the surface dose ranged between 0.19 cGy in head region during head scan and 4.55 cGy in the pelvis region during spot light scan. However, the internal dose ranged between 0.47 cGy in the head region during head scan and 5.55 cGy in the pelvis region during spot light scan. The average (internal and external) dose ranged between 0.45 cGy in the head region during head scan and 3.59 cGy in the pelvis region during spot light scan. Both Gafchromic XRQA2 film and nanoDot OSLDs gave close estimation of dose (within uncertainties) in many cases. Though, discrepancies of up to 20%-30% were observed in some cases. Conclusions: Dose response curves of Gafchromic XRQA2 film and nanoDot OSLDs indicated that the dose responses of these two dosimeters were different even at the same photon energy when different filters were used. Uncertainty levels of both dosimetry systems were below 6% at doses above 1 cGy. Both dosimetry systems gave almost similar estimation of doses (within uncertainties) in many cases, with exceptions of some cases when the discrepancy was around 20%-30%. New versions of the CBCT systems (investigated in this study) resulted in lower imaging doses compared with doses reported on earlier versions in previous studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Verification Using Monte Carlo Calculations for Tissue Heterogeneity-Corrected Conformal Treatment Plans Following RTOG 0813 Dosimetric Criteria for Lung Cancer Stereotactic Body Radiotherapy

Purpose: The recently activated Radiation Therapy Oncology Group (RTOG) studies of stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC) require tissue density heterogeneity correction, where the high and intermediate dose compliance criteria were established based on superposition algorithm dose calculations. The study was aimed at comparing superposition algorithm dose calculations with Monte Carlo (MC) dose calculations for SBRT for NSCLC and to evaluate whether compliance criteria need to be adjusted for MC dose calculations. Methods and Materials: Fifteen RTOG 0236 study sets were used. The planning tumor volumes (PTV) ranged from 10.7 to 117.1 cm{sup 3}. SBRT conformal treatment plans were generated using XiO (CMS Inc.) treatment planning software with superposition algorithm to meet the dosimetric high and intermediate compliance criteria recommended by the RTOG 0813 protocol. Plans were recalculated using the MC algorithm of a Monaco (CMS, Inc.) treatment planning system. Tissue density heterogeneity correction was applied in both calculations. Results: Overall, the dosimetric quantities of the MC calculations have larger magnitudes than those of the superposition calculations. On average, R{sub 100%} (ratio of prescription isodose volume to PTV), R{sub 50%} (ratio of 50% prescription isodose volume to PTV), D{sub 2cm} (maximal dose 2 cm from PTV in any direction as a percentage of prescription dose), and V{sub 20} (percentage of lung receiving dose equal to or larger than 20 Gy) increased by 9%, 12%, 7%, and 18%, respectively. In the superposition plans, 3 cases did not meet criteria for R{sub 50%} or D{sub 2cm}. In the MC-recalculated plans, 8 cases did not meet criteria for R{sub 100%}, R{sub 50%}, or D{sub 2cm}. After reoptimization with MC calculations, 5 cases did not meet the criteria for R{sub 50%} or D{sub 2cm}. Conclusions: Results indicate that the dosimetric criteria, e.g., the criteria for R{sub 50%} recommended by RTOG 0813 protocol, may need to be adjusted when the MC dose calculation algorithm is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel curvilinear approach for prostate seed implantation

Purpose: A new technique called ''curvilinear approach'' for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. Methods: Twenty LDR prostate brachytherapy cases planned intraoperatively with VariSeed planning system and I-125 seeds were randomly selected as reference rectilinear cases. All the cases were replanned by using curved-needle approach keeping the same individual source strength and the volume receiving 100% of prescribed dose 145 Gy (V{sub 100}). Parameters such as number of needles, seeds, and the dose coverage of the prostate (D{sub 90}, V{sub 150}, V{sub 200}), urethra (D{sub 30}, D{sub 10}) and rectum (D{sub 5}, V{sub 100}) were compared for the rectilinear and the curvilinear methods. Statistical significance was assessed using two-tailed student's t-test. Results: Reduction of the required number of needles and seeds in curvilinear method were 30.5% (p < 0.001) and 11.8% (p < 0.49), respectively. Dose to the urethra was reduced significantly; D{sub 30} reduced by 10.1% (p < 0.01) and D{sub 10} reduced by 9.9% (p < 0.02). Reduction in rectum dose D{sub 5} was 18.5% (p < 0.03) and V{sub 100} was also reduced from 0.93 cc in rectilinear to 0.21 cc in curvilinear (p < 0.001). Also the V{sub 150} and V{sub 200} coverage of prostate reduced by 18.8% (p < 0.01) and 33.9% (p < 0.001), respectively. Conclusions: Significant improvement in the relevant dosimetric parameters was observed in curvilinear needle approach. Prostate dose homogeneity (V{sub 150}, V{sub 200}) improved while urethral dose was reduced, which might potentially result in better treatment outcome. Reduction in rectal dose could potentially reduce rectal toxicity and complications. Reduction in number of needles would minimize edema and thereby could improve postimplant urinary incontinence. This study indicates that the curvilinear implantation approach is dosimetrically superior to conventional rectilinear implantation technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An unusual mono-substituted Keggin anion-chain based 3D framework with 24-membered macrocycles as linker units

A new compound, [Cu{sup I}(H{sub 2}O)(Hbpp){sub 2}] Subset-Of {l_brace}[Cu{sup I}(bpp)]{sub 2}[PW{sub 11}Cu{sup II}O{sub 39}]{r_brace} (1) (bpp=1,3-bis(4-pyridyl)propane), has been hydrothermally synthesized and structurally characterized by single crystal X-ray diffraction. In compound 1, the unusual -A-B-A-B- array mono-substituted Keggin anion-chains and 24-membered (Cubpp){sub 2} cation-macrocycles are linked together to form a (2, 4) connected 3D framework with channels of ca. 9.784 Multiplication-Sign 7.771 A{sup 2} along two directions, in which the [Cu(H{sub 2}O)(Hbpp){sub 2}] coordination fragments as guest components are trapped. The photocatalytic experiments of compound 1 were performed, which show a good catalytic activity of compound 1 for photodegradation of RhB. Furthermore, the IR, TGA and electrochemical properties of compound 1 were investigated. - Graphical abstract: An unusual example of mono-substituted Keggin anion-chain based hybrid compound that possesses a 3D structure has been synthesized, which offers a feasible route for synthesis of such compounds. Highlights: Black-Right-Pointing-Pointer The first example of -A-B-A-B- array mono-substituted Keggin chain is observed. Black-Right-Pointing-Pointer An unusual three dimensional structure based mono-substituted Keggin anion-chains. Black-Right-Pointing-Pointer The photocatalysis and electrochemical properties of the title compound were studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characteristics of Gafchromic XRQA2 films for kV image dose measurement

Purpose: In this study, the relevant characteristics of the new Gafchromic XRQA2 film for its application in measuring kV cone beam computed tomography (CBCT) image doses were thoroughly investigated. Methods: The film was calibrated free in air to air kerma levels between 0 and 9 cGy using 120 kVp photon beams produced by the x-ray volume imager. Films were scanned using transmission and reflection scanning modes with the Epson Expression 10000 XL flat-bed document scanner. The impact of film size, region of interest for the analysis, scan uniformity, scan resolution, scan orientation and alternate scanning sides on the analysis process were investigated. Energy dependence, postirradiation growth of reflectance with time and irradiation angular dependence of the film were tested at different air kerma levels. Results: The net reflectance changed by {approx}3% when the size of the film piece changed from 1 cm x 2 cm to 10 cm x 11 cm and changed by {approx}1% when ROI changed from 0. 7 cm x 0. 7 cm to 8 cm x 8 cm, suggesting a good uniformity of the film. The film was successfully analyzed using the transmission scanning mode, calibration curves from both transmission and reflection scanning modes showed similar behavior. The calibration uncertainty was somewhat lower when the film was scanned using reflection mode (6% and 8% for reflection and transmission modes, respectively.) Higher scanning resolution came with increasing calibration uncertainty. The calibration uncertainty for reflection and transmission modes increased from {approx}3.5% to 7% and from {approx}3.5% to 9%, respectively when scanning resolution was changed from 50 to 400 dpi. Scanning the film on alternate sides using transmission mode led to variation of 16%-19% in the net optical density at doses commonly used for CBCT procedures. The film response changed by almost 10% when it was exposed to beams of two different energies (100 and 120 kVp.) Other features of the film such as film orientation, postexposure growth, and irradiation angular dependence were also investigated. Conclusions: The size of film piece and analysis ROI used for calibration slightly affected the film response. Both transmission and reflection scanning modes can be used to analyze the Gafchromic XRQA2, with the reflection mode having a somewhat lower calibration uncertainty. Scanning films on alternate sides using transmission mode significantly affects the optical density. The film response was shown to be energy dependent. The films reached stability in about 6 h after exposure. The film response was proven to be independent of irradiation angle except when the beam is parallel to the film surface.

61 RADIATION PROTECTION AND DOSIMETRY↗

Large electric-induced pyroelectric properties in (Pb{sub 0.87}La{sub 0.02}Ba{sub 0.1}) (Zr{sub 0.7}Sn{sub 0.24}Ti{sub 0.06})O{sub 3} antiferroelectric ceramics with excess PbO

(Pb{sub 0.87}La{sub 0.02}Ba{sub 0.1}) (Zr{sub 0.7}Sn{sub 0.24}Ti{sub 0.06})O{sub 3} (PLBZST) antiferroelectric ceramics with the addition of 0-9 wt. % excess PbO were fabricated by the conventional solid-state reaction process, and their microstructure, dielectric, and pyroelectric properties were systemically investigated. When excess PbO content was less than 9 wt. %, two pyrochlore phases were formed along with the perovskite phase. Compared with common specimens, PLBZST antiferroelectric ceramics with excess PbO exhibited a higher pyroelectric coefficient and a lower dielectric loss, which are beneficial for the development of pyroelectric devices. Around the Curie temperature, as the excess PbO increased from 0 wt. % to 9 wt. %, PLBZST ceramics' pyroelectric coefficient increased from 1600 {mu}C/m{sup 2}K to 4000 {mu}C/m{sup 2}K, and the figure of merit increased from 40 x 10{sup -5} Pa{sup -0.5} to 140 x 10{sup -5} Pa{sup -0.5} under a 400 V/mm dc field. The largest figure of merit of 200 x 10{sup -5} Pa{sup -0.5}, which is about 8 times higher than that of conventional phase transition materials barium strontium titanate (BST), was obtained in PLBZST ceramics with 6 wt. % excess PbO when a 600 V/mm dc bias field was applied. Therefore, improvement of pyroelectric property is beneficial for the development of infrared detectors.

36 MATERIALS SCIENCE↗

AAPM recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: Report of Task Group 137

During the past decade, permanent radioactive source implantation of the prostate has become the standard of care for selected prostate cancer patients, and the techniques for implantation have evolved in many different forms. Although most implants use {sup 125}I or {sup 103}Pd sources, clinical use of {sup 131}Cs sources has also recently been introduced. These sources produce different dose distributions and irradiate the tumors at different dose rates. Ultrasound was used originally to guide the planning and implantation of sources in the tumor. More recently, CT and/or MR are used routinely in many clinics for dose evaluation and planning. Several investigators reported that the tumor volumes and target volumes delineated from ultrasound, CT, and MR can vary substantially because of the inherent differences in these imaging modalities. It has also been reported that these volumes depend critically on the time of imaging after the implant. Many clinics, in particular those using intraoperative implantation, perform imaging only on the day of the implant. Because the effects of edema caused by surgical trauma can vary from one patient to another and resolve at different rates, the timing of imaging for dosimetry evaluation can have a profound effect on the dose reported (to have been delivered), i.e., for the same implant (same dose delivered), CT at different timing can yield different doses reported. Also, many different loading patterns and margins around the tumor volumes have been used, and these may lead to variations in the dose delivered. In this report, the current literature on these issues is reviewed, and the impact of these issues on the radiobiological response is estimated. The radiobiological models for the biological equivalent dose (BED) are reviewed. Starting with the BED model for acute single doses, the models for fractionated doses, continuous low-dose-rate irradiation, and both homogeneous and inhomogeneous dose distributions, as well as tumor cure probability models, are reviewed. Based on these developments in literature, the AAPM recommends guidelines for dose prescription from a physics perspective for routine patient treatment, clinical trials, and for treatment planning software developers. The authors continue to follow the current recommendations on using D{sub 90} and V{sub 100} as the primary quantities, with more specific guidelines on the use of the imaging modalities and the timing of the imaging. The AAPM recommends that the postimplant evaluation should be performed at the optimum time for specific radionuclides. In addition, they encourage the use of a radiobiological model with a specific set of parameters to facilitate relative comparisons of treatment plans reported by different institutions using different loading patterns or radionuclides.

61 RADIATION PROTECTION AND DOSIMETRY↗

A direct micropipette-based calibration method for atomic force microscope cantilevers

In this report, we describe a direct method for calibrating atomic force microscope (AFM) cantilevers with the micropipette aspiration technique (MAT). A closely fitting polystyrene bead inside a micropipette is driven by precisely controlled hydrostatic pressures to apply known loads on the sharp tip of AFM cantilevers, thus providing a calibration at the most functionally relevant position. The new method is capable of calibrating cantilevers with spring constants ranging from 0.01 to hundreds of newtons per meter. Under appropriate loading conditions, this new method yields measurement accuracy and precision both within 10%, with higher performance for softer cantilevers. Furthermore, this method may greatly enhance the accuracy and precision of calibration for colloidal probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗