Search NASA⌕ Search

Engineering topics

Yana Motta, Samuel

Publications and source records attributed to Yana Motta, Samuel.

Mitigation of Safety and Environmental Challenges Posed by Low and Ultra-low GWP Refrigerants

The abatement of safety and environmental burden associated with low and ultra-low Global Warming Potential (GWP) refrigerants is a critical undertaking. As the industry shifts towards more environmentally friendly alternatives, mitigating the potential risks and ensuring safety standards becomes paramount. The adoption of low GWP and ultra-low GWP refrigerants contributes significantly to minimizing the greenhouse gas impact on the environment, aligning with global climate and sustainability goals. However, it is essential to address safety concerns and potential environmental implications associated with the end use of these refrigerants.A method to mitigate the safety risk in a flammable refrigerant based HVACR system is the primary focus of this paper. Advent of A2L and A3 refrigerants as replacements to high GWP refrigerants requires careful handling of leak episodes to lower or eliminate the risk associated with creating flammable mixtures capable of fire/explosion hazard. Solid materials tailored to target the molecule of interest (i.e., refrigerant.) by engineering the microporous structure as well as chemically functionalizing the surface to attract and hold on to the chemical compound being removed from the gas stream was realized. Additionally, a chromatic transformation technique is investigated for rapid on-site analysis of refrigerant blends. Preliminary results demonstrating the feasibility of both of these methods for successful deployment of low-GWP refrigerants are presented.

Cheekatamarla, Praveen↗

Experimental Study on Flow Condensation of Low Global Warming Potential Refrigerants in a Micro-fin Aluminum Tube

This study investigates the dynamic shifts in refrigerant technologies driven by environmental regulations, particularly emphasizing low global warming potential (GWP). Moreover, there is a rising trend in the adoption of aluminum tubes with internal axial micro-fin structures in heat exchangers to reduce costs. The research focuses on the condensation process within an expanded axial micro-fin aluminum tube with a 5.96 mm fin-tip diameter. Various refrigerants are analyzed, including both single compounds (R-32, R-1234yf, R-1234ze(E)) and zeotropic mixtures (R-454B, R-454C, R-455A). Experimental procedures cover a range of condensation temperatures (35~45 °C), reduced pressures (0.21~0.55), and mass fluxes (150~350 kg/(m² s)), providing crucial data on heat transfer coefficients (HTC) and frictional pressure gradient (FPG). This data is particularly significant for high-glide refrigerants and is instrumental in the design of advanced air conditioning and refrigeration systems aimed at mitigating global warming.

Hu, Yifeng↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Atmospheric Transformation of Refrigerants: Current Research Developments and Knowledge Gaps

Refrigerants have evolved through the years to reduce their global warming potential while providing sufficient cooling in refrigeration systems. Replacements for hydrofluorocarbons (HFCs) and chlorofluorocarbons (CFCs) are the hydrofluoroolefins (HFOs), which contain reactive double bonds that decrease the atmospheric lifetime of fluorinated compounds. However, the transformation of unsaturated fluorinated compounds in the atmosphere could generate persistent pollutants, particularly trifluoroacetic acid (TFA) which is the simplest Perfluoroalkyl carboxylic acids (PFCAs). Understanding the transformation of refrigerants is critical in assessing their contribution to atmospheric levels of TFA and their impact on watersheds and human health. This article will present the reactivity of the refrigerants, atmospheric oxidation source, and sink processes of fluorinated refrigerants under daytime conditions, particularly the variability of TFA from refrigerants. Moreover, the discussion will suggest experimental procedures that can quantify the low concentration (~parts per trillion) of TFA generated from the transformation of HFOs. New state-of-the-art techniques such as chemical ionization mass spectrometers (HR-CIMS) will be assessed in providing high temporal resolution (minutes to hourly) to fully capture the atmospheric sources and variability of TFA. Likewise, local, regional, and global concentrations of TFA accounted from the oxidation of refrigerants will be examined. This will include data from both experimental procedures and simulation models. Participation of TFA in critical atmospheric processes such as new particle formation will also be included in this study. Lastly, overall knowledge gaps related to the oxidation products and their dispersion in the environment will be summarized to guide future research needs.

Salvador, Christian↗

Evaluation of Leak Detection Technologies for Low Global Warming Potential (GWP), Flammable Refrigerants

Current commercial refrigeration systems use refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The emergence of low GWP alternatives (GWP <150) is expected to significantly reduce direct emissions in this sector, playing a crucial role in the ongoing electrification and decarbonization initiatives. However, many of these low GWP alternatives pose a flammability risk, necessitating robust sensing solutions to ensure the reliable and safe operation of the equipment. This paper examines various sensing mechanisms suitable for potential applications in systems that employ flammable refrigerants, specifically those designated as A2L class. It provides a summary of A2L refrigerants and their properties, followed by a comprehensive review of sensor classes, covering their working principles, features, advantages, and limitations. Additionally, the article delves into key performance characteristics such as accuracy, selectivity, sensitivity, dynamic characteristics, and durability, among other properties. The article discusses areas for improvement and suggests corresponding approaches for potential sensors in facilitating the successful adoption of flammable refrigerants. Finally, this paper presents the latest findings from experimental evaluation of 5 different sensing principles in detecting the composition variation as a result of various operational conditions. Reliability and sensitivity of the sensor in responding to shifts in true composition and the resultant LFL value is also discussed.

Reshniak, Viktor↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗

A Review of Sensing Technologies for New, Low Global Warming Potential (GWP), Flammable Refrigerants

Commercial refrigeration systems currently utilize refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The advent of low GWP alternatives (GWP <150) is expected to significantly curtail direct emissions from this segment and greatly influence the ongoing electrification and decarbonization efforts. Most of the low GWP alternatives exhibit flammability risk and hence require robust sensing solutions for a reliable and safe operation of the equipment. This review article aims to provide an overview of different sensing mechanisms suitable for potential applications in systems employing flammable refrigerants, particularly those designated as A2L class. A summary of different A2L refrigerants and their properties is provided followed by a broad review of different classes of sensors, their working principle, transduction method, features, advantages, and limitations. Additionally, key performance characteristics of accuracy, selectivity, sensitivity, dynamic characteristic, and durability among other properties are discussed. Finally, areas of improvement and corresponding approaches are suggested for potential sensors in the successful adoption of A2L class refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct Expansion Heat Pump Using High Glide Low GWP Refrigerant

Next generation of refrigerants require drastically lower global warming potential (GWP). The refrigerant mixtures, with a GWP < 150, e.g., R-457A, etc., tend to have significant temperature glide, which prefer multi-row, cross counter flow configuration. Typical heat pump operation reverses the refrigerant flow direction, compared to the air flow, from cooling mode to heating mode. It is difficult to configurate cross counter-flow heat exchangers in heat pumps. We invented an innovative configuration, having check valve assembly to maintain uniform cross counter flow configuration in both cooling and heat modes, which optimizes the performance of a high temperature slide refrigerant mixture, i.e. R-457A. Based on it, we developed a laboratory prototype, using a 2-stage compressor, achieved a cooling SEER (cooling seasonal energy efficiency rating) of 16.0 (cooling seasonal COP of 4.69) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP of 2.78). The unit was tested in an extensive ambient condition, heating operation from 5˚F to 62˚F (-15˚C to 16.7˚C); cooling operation from 82˚F to 95˚F (27.8˚C to 35˚C). The paper will introduce the system configuration, heat exchanger dimensions and laboratory investigations.

Shen, Bo↗

Building Technologies Office 03.02.02.38 Milestone Report—Compressor Technology Development for Refrigerants with <150 Global Warming Potential

The major purpose of this project is to enable the development of compressors specifically designed for compatibility with low–global warming potential (GWP) refrigerants (with GWP values below 150). These compressors are intended for applications in residential and light commercial air-conditioning and heat pump systems. This report contains an exhaustive review of the existing literature with the intention of discerning the most efficacious methodologies currently in use for compressor modeling. This fundamental stage was designed to foster a comprehensive understanding of the intricate dynamics and mechanics of compressors. As a result, a model (PDSim) was selected to simulate scroll, rotary and linear compressor technologies.

42 ENGINEERING↗

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Material Compatibility of 3D Printed Polymer Composites with Low GWP Refrigerants

The recent development of 3D printing brings numerous opportunities to develop polymer heat exchangers with desired configurations and allows access to the new complex engineering design for better performance. To be used in the HVAC&R system, the compatibility of these materials to refrigerants needs to be thoroughly investigated and understood. This study tested the material compatibility of the printed polymer composites according to the ASHRAE Guideline 38 using metal pressure vessels. These printed parts were tested with R-134A, R-1234YF, R-1234ZE, R-1233ZD(E), and 32-3 MAF POE (10 wt.%) was used as the lubricants. The change in volume, mass, hardness, and mechanical properties was studied in detail. Different compatibility of the composites with refrigerants was observed when the composition of the composite changed. After exposure to refrigerants, the morphological and thermal properties were studied with the scanning electron microscope, thermogravimetric analysis, and differential scanning calorimetry to further reveal the influence of these refrigerants.

Li, Kai↗

Critical Analysis of Replacements for R-410A in Heat Pump Applications

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Research has shown that using heat exchangers with small diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants due to reduced refrigerant charge, reduced flammable impact and environmental impact. However, application of small diameter tube requires in-depth component design optimization to make the new system adapt to low-GWP refrigerants.In this paper, multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm on a R-410A residential 5-ton air source heat pump is performed for improved system performance and reduced material cost. Five R-410A alternatives, i.e., R-32, R-454A, R-454B, R-454C and R-455A are investigated. R-455A and R-454C have GWP lower than 150. As a result of optimization, 12.4%-19.1% Energy Efficiency Ratio (EER) improvement and up to 71% HXs material cost saving is achieved. Life Cycle Climate Performance (LCCP) analysis shows that optimized systems reduce total CO2 emission by 13%-33% depending on the choice of refrigerant and climate zone.The optimal heat exchangers resulting from this research can fit into the original R-410A fan-coil units. The proposed heat pump design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Low-GWP Refrigerants Status and Outlook

Refrigeration - including air conditioning (AC) – contributes substantially to the modern life of the 21st century and its economy. The food cold chain, air conditioning, healthcare and energy are examples of sectors for which refrigeration is indispensable. About 5 billion refrigeration systems – of different types and sizes– operate worldwide in different applications [1]. The dominant share of equipment providing refrigeration operate on the vapor-compression-cycle principle and use fluorocarbon refrigerants. Concerns about the environmental safety have become the driving force for refrigerant changes within the last 35 years. The phased-out schedule of stratospheric-ozone-depleting fluids was first formulated by the Montreal Protocol (MP) in 1987 and was made more stringent during the follow-up international meetings [2]. The affected chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants were largely replaced by hydrofluorocarbons (HFCs).The 2016 Kigali Amendment to the MP [3] responses to the concerns about the Earth climate change. The refrigeration and AC sectors are attributed with about 7.8 % of global greenhouse gas emissions [4]. This contribution comes in the form of direct effect, which is related to refrigerant emissions from refrigeration systems (37 %), and in the form of indirect effect, which is related to CO2 emissions from fossil fuel power plants producing electricity to power refrigeration systems (63 %) [4]. The Kigali Amendment aims at reducing the direct effect. The effect a given molecule has on the climate change is quantified in a simplified manner by its Global Warming Potential (GWP), a relative index referencing the effect produced to that of the same mass of carbon dioxide released to the atmosphere. By definition, GWP of carbon dioxide is equal to one.While HFC refrigerants have on average a lower GWP than the CFCs and HCFCs they replaced, they are still potent greenhouse gases (GHGs). The Kigali Amendment phases down the use of HFCs by imposing a schedule for reducing a weighted GWP value to be implemented by a country through the year 2047 (Figure 1). It provides four paths depending on the country location and category assigned in the MP, and also prescribes a method for establishing the baseline consumption used for calculating GWP reductions. For developing countries, it is expected to bring the weighed GWP across all refrigeration applications down to about 300 from the baseline value of about 2000. The implementation of Kigali Amendment aims at reducing the future warming due to HFCs from the range of 0.3 °C to 0.5 °C to less than 0.1 °C [5]. While this reduction may seem to be small, it must be viewed in the context of the 2015 Paris Agreement [6], which calls for holding global warming to well below 2 °C and pursuing to limit global warming to 1.5 °C relative to pre-industrial levels [6]. Considering that average global temperatures reached 1 °C above pre-industrial levels for the first time in 2015 [7], the Earth is already within 1 °C of the “2 °C limit”.The low-GWP requirement narrows the pool of fluids that can be considered for application as a refrigerant [8]. This Informatory Note discusses low-GWP refrigerant options for major applications and presents their selection merits.

Yana Motta, Samuel↗

Optimization of Residential Air Source Heat Pump using Low–Global Warming Potential Refrigerants

We report low–global warming potential refrigerants can significantly reduce the direct emissions of CO 2 originating from HVAC systems. However, high-efficiency systems are needed to reduce indirect CO 2 emissions. In this study, an R410A residential 5-Ton heat pump was optimized using R32, R454A, R454B, R454C, and R455A. Among these options, R455A and R454C have the lowest global warming potential but have lower volumetric capacity and high glide. Optimization results using 5 mm tube heat exchangers showed 12.4% to 19.1% efficiency improvements and 13% to 33% reduction in CO 2 emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗