Search NASA⌕ Search

Engineering topics

Yang, G.

Publications and source records attributed to Yang, G..

At least 19 records

The BUTTON-30 detector at Boulby

The BUTTON-30 detector is a 30-tonne technology demonstrator designed to evaluate the potential of hybrid event detection, simultaneously exploiting both Cherenkov and scintillation light to detect particles produced in neutrino interactions. The detector is installed at a depth of 1.1 km in the Boulby Underground Laboratory allowing to test the performance of this new technology underground in a low background environment. This paper describes the design and construction of the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and development of optical modules for the BUTTON-30 detector

BUTTON-30 is a neutrino detector demonstrator located in the STFC Boulby underground facility in the north-east of England. The main goal of the project is to deploy and test the performance of the gadolinium-loaded water-based liquid scintillator for neutrino detection in an underground environment. This will pave the way for a future large-volume neutrino observatory that can also perform remote monitoring of nuclear reactors for nonproliferation. This paper describes the design and construction of the watertight optical modules of the experiment.

COMSOL simulations↗

Design, construction, and operation of a 1-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

Water-based liquid scintillators (WbLS) are a new class of detector materials that provide efficient and tunable detection of both Cherenkov and scintillation light. A massive WbLS neutrino detector with suitable photosensor coverage for low intensity light detection could therefore reconstruct the momentum of an energetic charged particle and also have enhanced low-energy sensitivity. These materials are also better suited for metal doping broadening the potential scientific utility. Here, we recently constructed and commissioned a 1-ton WbLS detector with good photosensor coverage and a capable data acquisition and calibration system. We intend to use this flexible detector system as a testbed for WbLS R&D. In this paper we give an overview of the 1-ton system and provide some early results.

47 OTHER INSTRUMENTATION↗

Direct WIMP detection rates for transitions in isomeric nuclei

The direct detection of dark matter constituents, in particular the weakly interacting massive particles (WIMPs), is central to particle physics and cosmology. In this paper we study WIMP induced transitions from isomeric nuclear states for two possible isomeric candidates: 180 Ta and 166 Ho. The experimental setup, which can measure the possible decay of 180 Ta induced by WIMPs, was proposed. The corresponding estimates of the half-life of 180 Ta are given in the sense that the WIMP-nucleon interaction can be interpreted as ordinary radioactive decay.

47 OTHER INSTRUMENTATION↗

Electron scattering and neutrino physics

Abstract A thorough understanding of neutrino–nucleus scattering physics is crucial for the successful execution of the entire US neutrino physics program. Neutrino–nucleus interaction constitutes one of the biggest systematic uncertainties in neutrino experiments—both at intermediate energies affecting long-baseline deep underground neutrino experiment, as well as at low energies affecting coherent scattering neutrino program—and could well be the difference between achieving or missing discovery level precision. To this end, electron–nucleus scattering experiments provide vital information to test, assess and validate different nuclear models and event generators intended to test, assess and validate different nuclear models and event generators intended to be used in neutrino experiments. Similarly, for the low-energy neutrino program revolving around the coherent elastic neutrino–nucleus scattering (CEvNS) physics at stopped pion sources, such as at ORNL, the main source of uncertainty in the evaluation of the CEvNS cross section is driven by the underlying nuclear structure, embedded in the weak form factor, of the target nucleus. To this end, parity-violating electron scattering (PVES) experiments, utilizing polarized electron beams, provide vital model-independent information in determining weak form factors. This information is vital in achieving a percent level precision needed to disentangle new physics signals from the standard model expected CEvNS rate. In this white paper, we highlight connections between electron- and neutrino–nucleus scattering physics at energies ranging from 10 s of MeV to a few GeV, review the status of ongoing and planned electron scattering experiments, identify gaps, and lay out a path forward that benefits the neutrino community. We also highlight the systemic challenges with respect to the divide between the nuclear and high-energy physics communities and funding that presents additional hurdles in mobilizing these connections to the benefit of neutrino programs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron detection and application with a novel 3D-projection scintillator tracker in the future long-baseline neutrino oscillation experiments

Neutrino oscillation experiments require a precise measurement of the neutrino energy. However, the kinematic detection of the final-state neutron in the neutrino interaction is missing in current neutrino oscillation experiments. The missing neutron kinematic detection results in a smaller detected neutrino energy than the true neutrino energy. A novel 3D-projection scintillator tracker, which consists of roughly ten million active cubes covered with an optical reflector, is capable of measuring the neutron kinetic energy and direction on an event-by-event basis using the time-of-flight technique thanks to the fast timing, fine granularity, and high light yield. The $\overline{v}$ μ interactions tend to produce neutrons in the final state. By measuring the neutron kinetic energy, the $\overline{v}$ μ energy can be reconstructed better, allowing a tighter incoming neutrino flux constraint. This article shows the detector's ability to reconstruct neutron kinetic energy and the $\overline{v}$ μ flux constraint achieved by selecting the charged-current interactions without mesons or protons in the final state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Eos: conceptual design for a demonstrator of hybrid optical detector technology

Eos is a technology demonstrator, designed to explore the capabilities of hybrid event detection technology, leveraging both Cherenkov and scintillation light simultaneously. With a fiducial mass of four tons, Eos is designed to operate in a high-precision regime, with sufficient size to utilize time-of-flight information for full event reconstruction, flexibility to demonstrate a range of cutting edge technologies, and simplicity of design to facilitate potential future deployment at alternative sites. Results from Eos can inform the design of future neutrino detectors for both fundamental physics and nonproliferation applications. This paper describes the conceptual design and potential applications of the Eos

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for signatures of sterile neutrinos with Double Chooz

We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e. comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range ${5 \times 10^{-3}}\,\mathrm{eV}^2 \lesssim \varDelta m^2_{41} \lesssim {3 \times 10^{-1}}\,\mathrm{eV}^2$ for mixing angles down to $\sin ^2 2\theta _{14} \gtrsim {0.02}$. No significant disappearance additionally to the conventional disappearance related to $\theta _{13}$ is observed and correspondingly exclusion bounds on the sterile mixing parameter $\theta _{14}$ as a function of $\varDelta m^2_{41}$ are obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reactor rate modulation oscillation analysis with two detectors in Double Chooz

A θ 13 oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of θ 13 and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data collected in both detectors with at least one reactor in operation. The oscillation results are enhanced by the use of 24.06 days (12.74 days) of reactor-off data in the far (near) detector. The analysis considers the ${\overline{\nu}}_e$ interactions up to a visible energy of 8.5 MeV, using the events at higher energies to build a cosmogenic background model considering fast-neutrons interactions and 9 Li decays. The background-model-independent determination of the mixing angle yields sin 2 (2 θ 13 ) = 0.094 ± 0.017, being the best-fit total background rates fully consistent with the cosmogenic background model. A second oscillation analysis is also performed constraining the total background rates to the cosmogenic background estimates. While the central value is not significantly modified due to the consistency between the reactor-off data and the background estimates, the addition of the background model reduces the uncertainty on θ 13 to 0.015. Along with the oscillation results, the normalization of the anti-neutrino rate is measured with a precision of 0.86%, reducing the 1.43% uncertainty associated to the expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ProtoDUNE-SP LArTPC electronics production, commissioning, and performance

The ProtoDUNE-SP detector is a large-scale prototype of the Single-Phase (SP) Liquid Argon Time Projection Chamber (LArTPC) design proposed for the Deep Underground Neutrino Experiment (DUNE). 15,360 LArTPC wires are instrumented with low electronic noise pre-amplifier and digitization ASICs integrated into Front End Motherboards (FEMBs) operating at cryogenic temperature within the cryostat. The large number of electronics channels and high performance specifications required a large-scale production electronics quality control effort, careful installation into Anode Plane Assemblies (APAs), and rigorous detector commissioning. This successful collaboration-wide effort achieved a working LArTPC electronics channel percentage of 99.7% (15,318 of 15,360 channels in total), whose operating performance exceeded expectations. We summarize the ProtoDUNE-SP cold electronics design and quality control, installation, and commissioning efforts that enabled this excellent electronics performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Double Chooz {theta}13 measurement via total neutron capture detection

Neutrinos were assumed to be massless particles until the discovery of the neutrino oscillation process. This phenomenon indicates that the neutrinos have non-zero masses and the mass eigenstates (nu(1), nu(2), nu(3)) are mixtures of their flavour eigenstates (nu(e), nu(mu), nu(tau)). The oscillations between different flavour eigenstates are described by three mixing angles (theta(12), theta(23), theta(13)), two differences of the squared neutrino masses of the nu(2)/nu(1) and nu(3)/nu(1) pairs and a charge conjugation parity symmetry violating phase delta(CP). The Double Chooz experiment, located near the Chooz Electricite de France reactors, measures the oscillation parameter theta(13) using reactor neutrinos. Here, the Double Chooz collaboration reports the measurement of the mixing angle theta(13) with the new total neutron capture detection technique from the full data set, yielding sin(2)(2 theta(13)) = 0.105 +/- 0.014. This measurement exploits the multidetector configuration, the isoflux baseline and data recorded when the reactors were switched off. In addition to the neutrino mixing angle measurement, Double Chooz provides a precise measurement of the reactor neutrino flux, given by the mean cross-section per fission <sigma(f)& rang; = (5.71 +/- 0.06) x 10(-43) cm(2) per fission, and reports an empirical model of the distortion in the reactor neutrino spectrum. The Double Chooz collaboration reports the neutrino oscillation parameter theta(13) from a measurement of the disappearance of reactor anti-electron neutrinos with the total neutron capture technique.

Djurcic, Z.↗

Multiphysics Coupling of PROTEUS-NODAL and SAM for Molten Salt Reactor Simulation

The purpose of this report is to document the new features and capabilities that have been implemented in the PROTEUS-NODAL code and the coupling procedure of PROTEUS-NODAL with SAM to analyze MSRs. This report is organized as follows. Section 2 presents the variational nodal P 1 solver for cylindrical geometries and its verification test results. Section 3 discusses the transient analysis capability implemented in the P 1 solvers of PROTEUS-NODAL. The solution methods for the coupled system of TFSP and precursor drift equations, the coarse mesh finite difference (CMFD) acceleration, the kinetics parameter evaluation method, and the thermal feedback are discussed. The verification test results against the SP 3 solutions are also discussed. Section 4 describes the coupling scheme of PROTEUS-NODAL and SAM under the MOOSE framework for MSR applications. The developed MOOSE applications named “TreeFrog” and “TreeKangaroo” are discussed. Verification test results for the coupled system are also discussed by comparing the MSFR steady state solution with that obtained from a manually coupled PROTEUS-NODAL and ANSYS CFX computational fluid dynamics (CFD) calculations and the MSFR transient analysis results with the open literature solutions and the PROTEUS-NODAL solutions obtained with the standalone thermal-hydraulics solver. Section 5 provides conclusions and future works.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Role of Selenium Addition to CdZnTe Matrix for Room-Temperature Radiation Detector Applications

Because of its ideal band gap, high density and high electron mobility-lifetime product, cadmium zinc telluride (CdZnTe or CZT) is currently the best room-temperature compound-semiconductor X- and gamma-ray detector material. However, because of its innate poor thermo-physical properties and above unity segregation coefficient for Zn, the wide spread deployment of this material in large-volume CZT detectors is still limited by the high production cost. The underlying reason for the low yield of high-quality material is that CZT suffers from three major detrimental defects: compositional inhomogeneity, high concentrations of dislocation walls/sub-grain boundary networks and high concentrations of Te inclusions/precipitates. To mitigate all these disadvantages, we report for the first time the effects of the addition of selenium to the CZT matrix. The addition of Se was found to be very effective in arresting the formation of sub-grain boundaries and its networks, significantly reducing Zn segregation, improving compositional homogeneity and resulting in much lower concentrations of Te inclusions/precipitates. Growth of the new quaternary crystal Cd 1-x Zn x Te 1-y Se y (CZTS) by the Traveling Heater Method (THM) is reported in this paper. We have demonstrated the production of much higher yield according to its compositional homogeneity, with substantially lower sub-grain boundaries and their network, and a lower concentration of Te inclusions/precipitates.

36 MATERIALS SCIENCE↗

Charge-Transport Properties of As-Grown Cd 1-x Zn x Te 1-y Se y by the Traveling Heater Method

In this article, we report on the charge-transport characteristics of a new quaternary material Cd 1-x Zn x Te 1-y Se y (CZTS) grown by the Traveling Heater Method (THM). The as-grown CZTS material was found to possess fewer Te inclusions than CZT. Moreover, high resistivity of ~1-2x10 10 ohm-cm was achieved, meeting the requirements of most gamma-ray detector applications. The mobility-lifetime product for electrons [(µτ) e ] was measured to be ~4x10 -3 cm 2 /V. The energy resolution for the quasi-hemispherical detector fabricated from the as-grown CZTS ingot obtained was ~2.8% (FWHM) at 662 keV.

36 MATERIALS SCIENCE↗

Growth of CdMnTe free of large Te inclusions using the vertical Bridgman technique

Here, we grew Cd 1-x Mn x Te crystals with a nominal composition of 5% Mn and 95% Cd using the vertical Bridgman technique. We were able to grow crystals from as-received starting material that were free of secondary phases, such as Te inclusions with a size > 1-µm diameter, without adding compensating Cd to the initial charge. The Te precipitations (size < 1-µm diameter) were found to segregate towards the last-to-freeze section of the ingot. Te inclusions with a size 5-7 µm were observed at the grain boundary located near the last-to-freeze section, while the bottom and middle parts of the ingot showed no Te inclusions, even at the grain boundaries. X-ray topographic analysis was used to characterize the distribution of thermal stress in the ingot.

36 MATERIALS SCIENCE↗