Search NASA⌕ Search

Engineering topics

Yang, Xiaofeng

Publications and source records attributed to Yang, Xiaofeng.

At least 19 records

CFD simulations of electric motor end ring cooling for improved thermal management

Proper thermal management of an electric motor for vehicle applications extends its operating range. One cooling approach is to impinge Automatic Transmission Fluid (ATF) onto the rotor end ring. Increased ATF coverage correlates to enhanced heat transfer. Computational Fluid Dynamics (CFD) analytical tools provide a mechanism to assess motor thermal management prior to hardware fabrication. The complexity of the fluid flow (e.g., jet atomization, interface tracking, wall impingement) and heat transfer makes these simulations challenging. Computational costs are high when solving these flows on high-speed rotating meshes. Typically, a Volume-of Fluid (VOF) technique (i.e., two-fluid system) is used to resolve ATF dynamics within this rotating framework. Suitable numerical resolution of the relevant physics for thin films under strong inertial forces at high rotor speeds is computationally expensive, further increasing the run times. In this work, a numerical study of rotor-ring cooling by ATF is presented using a patent automated Cartesian cut-cell based method coupled with Automatic Mesh Refinement (AMR). This approach automatically creates the Cartesian mesh on-the-fly and can effectively handle complex rotating geometries by adaptively refining the mesh based on local gradients in the flow field which results in better resolution of the air-ATF interface. A Single non-inertial Reference Frame (SRF) approach is used to account for the rotating geometry and to further improve the overall computational efficiency. Quasi-steady state conditions are targeted in the analysis of the results. Important physics such as ATF jet structure, velocity detail near the air-jet interface, ATF coverage/accumulation on the ring surface, and cooling capacity are presented for a low-resolution Reynolds averaged Navier-Stokes (RANS), high-resolution RANS, and high-resolution Large-Eddy Simulation (LES) models. Computations are scaled over hundreds of cores on a supercomputer to maximize turnaround time. Each numerical approach is shown to capture the general trajectory of the oil jet prior to surface impingement. The high-resolution LES simulation, however, is superior in capturing small scale details and heat transfer between the free jet and surrounding air.

42 ENGINEERING↗

Discovery of TAK-981, a First-in-Class Inhibitor of SUMO-Activating Enzyme for the Treatment of Cancer

SUMOylation is a reversible post-translational modification that regulates protein function through covalent attachment of small ubiquitin-like modifier (SUMO) proteins. The process of SUMOylating proteins involves an enzymatic cascade, the first step of which entails the activation of a SUMO protein through an ATP-dependent process catalyzed by SUMO-activating enzyme (SAE). Here, we describe the identification of TAK-981, a mechanism-based inhibitor of SAE which forms a SUMO–TAK-981 adduct as the inhibitory species within the enzyme catalytic site. Optimization of selectivity against related enzymes as well as enhancement of mean residence time of the adduct were critical to the identification of compounds with potent cellular pathway inhibition and ultimately a prolonged pharmacodynamic effect and efficacy in preclinical tumor models, culminating in the identification of the clinical molecule TAK-981.

60 APPLIED LIFE SCIENCES↗

The Influence of Fabrication Methods on Structure and Microwave Absorption Property of Fe{sub 3}O{sub 4}/rGO Composites

In this study, flake graphite is used as raw material and oxidized to produce graphene oxide (GO), and then two kinds of ferroferric oxide/reduced graphene oxide (Fe{sub 3}O{sub 4}/rGO) composites are fabricated with one-step and two-step methods, respectively. The influence of composite methods on structure and performance is investigated by FT-IR, XRD, SEM, TEM, and testing of electromagnetic parameters. The results show that there are many advantages in the one-step method for fabrication of Fe{sub 3}O{sub 4}/rGO composite, such as the composite process is simplified, the time is shortened, and the Fe{sub 3}O{sub 4}/rGO composite fabricated with the one-step method has the best microwave impedance matching property in the frequency range of 2.5–6 GHz. At the same time, it can be found that there is the Fe–O–C bond in Fe{sub 3}O{sub 4}/rGO composites fabricated with the one-step method, which results in two ways of physical recombination and chemical bonding between Fe{sub 3}O{sub 4} and rGO sheet particulates. In addition, when the mass ratio of GO and FeCl{sub 3} is 1:10, the R{sub L} value of the Fe{sub 3}O{sub 4}/rGO composite fabricated with the one-step method is minimum, and the increase of sample thickness is beneficial to improve the impedance matching property of Fe{sub 3}O{sub 4}/rGO composite in the frequency range of 2.5–6 GHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evolution of Friction and Permeability in a Propped Fracture under Shear

We explore the evolution of friction and permeability of a propped fracture under shear. We examine the effects of normal stress, proppant thickness, proppant size, and fracture wall texture on the frictional and transport response of proppant packs confined between planar fracture surfaces. The proppant-absent and proppant-filled fractures show different frictional strength. For fractures with proppants, the frictional response is mainly controlled by the normal stress and proppant thickness. The depth of shearing-concurrent striations on fracture surfaces suggests that the magnitude of proppant embedment is controlled by the applied normal stress. Under high normal stress, the reduced friction implies that shear slip is more likely to occur on propped fractures in deeper reservoirs. The increase in the number of proppant layers, from monolayer to triple layers, significantly increases the friction of the propped fracture due to the interlocking of the particles and jamming. Permeability of the propped fracture is mainly controlled by the magnitude of the normal stress, the proppant thickness, and the proppant grain size. Permeability of the propped fracture decreases during shearing due to proppant particle crushing and related clogging. Proppants are prone to crushing if the shear loading evolves concurrently with the normal loading.

42 ENGINEERING↗

Numerical approximations for the molecular beam epitaxial growth model based on the invariant energy quadratization method

The Molecular Beam Epitaxial model is derived from the variation of a free energy, that consists of either a fourth order Ginzburg–Landau double well potential or a nonlinear logarithmic potential in terms of the gradient of a height function. One challenge in solving the MBE model numerically is how to develop proper temporal discretization for the nonlinear terms in order to preserve energy stability at the time-discrete level. In this paper, we resolve this issue by developing a first and second order time-stepping scheme based on the “Invariant Energy Quadratization” (IEQ) method. The novelty is that all nonlinear terms are treated semi-explicitly, and the resulted semi-discrete equations form a linear system at each time step. Moreover, the linear operator is symmetric positive definite and thus can be solved efficiently. We then prove that all proposed schemes are unconditionally energy stable. The semi-discrete schemes are further discretized in space using finite difference methods and implemented on GPUs for high-performance computing. Various 2D and 3D numerical examples are presented to demonstrate stability and accuracy of the proposed schemes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Linearly first- and second-order, unconditionally energy stable schemes for the phase field crystal model

In this paper, we develop a series of linear, unconditionally energy stable numerical schemes for solving the classical phase field crystal model. The temporal discretizations are based on the first order Euler method, the second order backward differentiation formulas (BDF2) and the second order Crank–Nicolson method, respectively. The schemes lead to linear elliptic equations to be solved at each time step, and the induced linear systems are symmetric positive definite. We prove that all three schemes are unconditionally energy stable rigorously. Various classical numerical experiments in 2D and 3D are performed to validate the accuracy and efficiency of the proposed schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parallel methodology to capture cyclic variability in motored engines

Numerical prediction of of cycle-to-cycle variability (CCV) in SI engines is extremely challenging for two key reasons: (i) high-fidelity methods such as large eddy simulation (LES) are require to accurately capture the in-cylinder turbulent flowfield, and (ii) CCV is experienced over long timescales and hence the simulations need to be performed for hundreds of consecutive cycles. In this study, a new methodology is proposed to dissociate this long time-scale problem into several shorter time-scale problems, which can considerably reduce the computational time without sacrificing the fidelity of the simulations. The strategy is to perform multiple single-cycle simulations in parallel by effectively perturbing the simulation parameters such as the initial and boundary conditions. It is shown that by perturbing the initial velocity field effectively based on the intensity of the in-cylinder turbulence, the mean and variance of the in-cylinder flowfield is captured reasonably well. Adding perturbations in the initial pressure field and the boundary pressure improves the predictions. It is shown that this new approach is able to give accurate predictions of the flowfield statistics in less than one-tenth of time required for the conventional approach of simulating consecutive engine cycles.

33 ADVANCED PROPULSION SYSTEMS↗

The Impact of Axillary Lymph Node Surgery on Breast Skin Thickening During and After Radiation Therapy for Breast Cancer

Purpose: This prospective study was conducted to determine predictors of epidermal thickening during and after whole-breast radiation therapy (XRT) using objective measurements acquired with ultrasound. Methods and Materials: After breast-conserving surgery, 70 women received a definitive course of whole-breast XRT (50 Gy plus boost). Prior to XRT, at week 6 of XRT, and 6 weeks after XRT, patients underwent objective ultrasound measurements of epidermal thickness over the lumpectomy cavity and all 4 quadrants of the treated breast. A skin thickness ratio (STRA) was then generated normalizing for corresponding measurements taken of the untreated breast. Results: Baseline measurements indicated that 87% of patients had skin thickening in the treated versus untreated breast (mean increase, 27%; SD, 0.29) prior to XRT. The STRA increased significantly by week 6 of XRT (mean, 25%; SD, 0.46) and continued to increase significantly 6 weeks after XRT (mean, 33%; SD, 0.46) above baseline measurements (P<.001 for both time points). On multivariate analysis, breast volume (P=.003) and surgical evaluation of the axilla with full lymph node dissection (P<.05) predicted for more severe changes in the STRA 6 weeks after XRT compared with baseline. STRA measurements correlated with physician ratings of skin toxicity according to Radiation Therapy Oncology Group grading criteria. Conclusions: This is one of the first studies to objectively document that lymph node surgery affects XRT-induced skin thickening in patients with breast cancer. Surgical evaluation of the axilla with complete lymph node dissection was associated with the most severe XRT-induced skin changes after XRT completion. These results may inform future studies aimed at minimizing side effects of XRT and surgery, particularly when surgical lymph node assessments may not alter breast cancer management or outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Ultrasonic Nakagami Imaging of Neck Fibrosis After Head and Neck Radiation Therapy

Purpose: To investigate the feasibility of ultrasound Nakagami imaging to quantitatively assess radiation-induced neck fibrosis, a common sequela of radiation therapy (RT) to the head and neck. Methods and Materials: In a pilot study, 40 study participants were enrolled and classified into 3 subgroups: (1) a control group of 12 healthy volunteers; (2) an asymptomatic group of 11 patients who had received intensity modulated RT for head and neck cancer and had experienced no neck fibrosis; and (3) a symptomatic group of 17 post-RT patients with neck fibrosis. Each study participant underwent 1 ultrasound study in which scans were performed in the longitudinal orientation of the bilateral neck. Three Nakagami parameters were calculated to quantify radiation-induced tissue injury: Nakagami probability distribution function, shape, and scaling parameters. Physician-based assessments of the neck fibrosis were performed according to the Radiation Therapy Oncology Group late morbidity scoring scheme, and patient-based fibrosis assessments were rated based on symptoms such as pain and stiffness. Results: Major discrepancies existed between physician-based and patient-based assessments of radiation-induced fibrosis. Significant differences in all Nakagami parameters were observed between the control group and 2 post-RT groups. Moreover, significant differences in Nakagami shape and scaling parameters were observed among asymptomatic and symptomatic groups. Compared with the control group, the average Nakagami shape parameter value increased by 32.1% (P<.001), and the average Nakagami scaling parameter increased by 55.7% (P<.001) for the asymptomatic group, whereas the Nakagami shape parameter increased by 74.1% (P<.001) and the Nakagami scaling parameter increased by 83.5% (P<.001) for the symptomatic group. Conclusions: Ultrasonic Nakagami imaging is a potential quantitative tool to characterize radiation-induced asymptomatic and symptomatic neck fibrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Segmentation of the Parotid Gland Based on Atlas Registration and Machine Learning: A Longitudinal MRI Study in Head-and-Neck Radiation Therapy

Purpose: To develop an automated magnetic resonance imaging (MRI) parotid segmentation method to monitor radiation-induced parotid gland changes in patients after head and neck radiation therapy (RT). Methods and Materials: The proposed method combines the atlas registration method, which captures the global variation of anatomy, with a machine learning technology, which captures the local statistical features, to automatically segment the parotid glands from the MRIs. The segmentation method consists of 3 major steps. First, an atlas (pre-RT MRI and manually contoured parotid gland mask) is built for each patient. A hybrid deformable image registration is used to map the pre-RT MRI to the post-RT MRI, and the transformation is applied to the pre-RT parotid volume. Second, the kernel support vector machine (SVM) is trained with the subject-specific atlas pair consisting of multiple features (intensity, gradient, and others) from the aligned pre-RT MRI and the transformed parotid volume. Third, the well-trained kernel SVM is used to differentiate the parotid from surrounding tissues in the post-RT MRIs by statistically matching multiple texture features. A longitudinal study of 15 patients undergoing head and neck RT was conducted: baseline MRI was acquired prior to RT, and the post-RT MRIs were acquired at 3-, 6-, and 12-month follow-up examinations. The resulting segmentations were compared with the physicians' manual contours. Results: Successful parotid segmentation was achieved for all 15 patients (42 post-RT MRIs). The average percentage of volume differences between the automated segmentations and those of the physicians' manual contours were 7.98% for the left parotid and 8.12% for the right parotid. The average volume overlap was 91.1% ± 1.6% for the left parotid and 90.5% ± 2.4% for the right parotid. The parotid gland volume reduction at follow-up was 25% at 3 months, 27% at 6 months, and 16% at 12 months. Conclusions: We have validated our automated parotid segmentation algorithm in a longitudinal study. This segmentation method may be useful in future studies to address radiation-induced xerostomia in head and neck radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0.86%, and the prostate volume Dice overlap coefficient was 91.89% ± 1.19%. Conclusions: The authors have developed a novel approach to improve prostate contour utilizing intraoperative TRUS-based prostate volume in the CT-based prostate HDR treatment planning, demonstrated its clinical feasibility, and validated its accuracy with MRIs. The proposed segmentation method would improve prostate delineations, enable accurate dose planning and treatment delivery, and potentially enhance the treatment outcome of prostate HDR brachytherapy.

60 APPLIED LIFE SCIENCES↗

Ultrasonic Nakagami-parameter characterization of parotid-gland injury following head-and-neck radiotherapy: A feasibility study of late toxicity

Purpose: The study aims to investigate whether Nakagami parameters—estimated from the statistical distribution of the backscattered ultrasound radio-frequency (RF) signals—could provide a means for quantitative characterization of parotid-gland injury resulting from head-and-neck radiotherapy. Methods: A preliminary clinical study was conducted with 12 postradiotherapy patients and 12 healthy volunteers. Each participant underwent one ultrasound study in which ultrasound scans were performed in the longitudinal, i.e., vertical orientation on the bilateral parotids. For the 12 patients, the mean radiation dose to the parotid glands was 37.7 ± 9.5 Gy, and the mean follow-up time was 16.3 ± 4.8 months. All enrolled patients experienced grade 1 or 2 late salivary-gland toxicity (RTOG/EORTC morbidity scale). The normal parotid glands served as the control group. The Nakagami-scaling and Nakagami-shape parameters were computed from the RF data to quantify radiation-induced parotid-gland changes. Results: Significant differences in Nakagami parameters were observed between the normal and postradiotherapy parotid glands. Compared with the control group, the Nakagami-scaling parameter of the postradiotherapy group decreased by 25.8% (p < 0.001), and the Nakagami-shape parameter decreased by 31.3% (p < 0.001). The area under the receiver operating characteristic curve was 0.85 for the Nakagami-scaling parameter and was 0.95 for the Nakagami-shape parameter, which further demonstrated the diagnostic efficiency of the Nakagami parameters. Conclusions: Nakagami parameters could be used to quantitatively measure parotid-gland injury following head-and-neck radiotherapy. Moreover, the clinical feasibility was demonstrated and this study provides meaningful preliminary data for future clinical investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory-Induced Prostate Motion Using Wavelet Decomposition of the Real-Time Electromagnetic Tracking Signal

Purpose: The objective of this work is to characterize and quantify the impact of respiratory-induced prostate motion. Methods and Materials: Real-time intrafraction motion is observed with the Calypso 4-dimensional nonradioactive electromagnetic tracking system (Calypso Medical Technologies, Inc. Seattle, Washington). We report the results from a total of 1024 fractions from 31 prostate cancer patients. Wavelet transform was used to decompose the signal to extract and isolate the respiratory-induced prostate motion from the total prostate displacement. Results: Our results show that the average respiratory motion larger than 0.5 mm can be observed in 68% of the fractions. Fewer than 1% of the patients showed average respiratory motion of less than 0.2 mm, whereas 99% of the patients showed average respiratory-induced motion ranging between 0.2 and 2 mm. The maximum respiratory range of motion of 3 mm or greater was seen in only 25% of the fractions. In addition, about 2% patients showed anxiety, indicated by a breathing frequency above 24 times per minute. Conclusions: Prostate motion is influenced by respiration in most fractions. Real-time intrafraction data are sensitive enough to measure the impact of respiration by use of wavelet decomposition methods. Although the average respiratory amplitude observed in this study is small, this technique provides a tool that can be useful if one moves to smaller treatment margins (≤5 mm). This also opens ups the possibility of being able to develop patient specific margins, knowing that prostate motion is not unpredictable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Non-Gaussian Nature of Prostate Motion Based on Real-Time Intrafraction Tracking

Purpose: The objective of this work is to test the validity of the Gaussian approximation for prostate motion through characterization of its spatial distribution. Methods and Materials: Real-time intrafraction prostate motion was observed using Calypso 4-dimensional (4D) nonradioactive electromagnetic tracking system. We report the results from a total of 1024 fractions from 31 prostate cancer patients. First, the correlation of prostate motion in right/left (RL), anteroposterior (AP), and superoinferior (SI) direction were determined using Pearson's correlation of coefficient. Then the spatial distribution of prostate motion was analyzed for individual fraction, individual patient including all fractions, and all patients including all fractions. The displacement in RL, AP, SI, oblique, or total direction is fitted into a Gaussian distribution, and a Lilliefors test was used to evaluate the validity of the hypothesis that the displacement is normally distributed. Results: There is high correlation in AP/SI direction (61% of fractions with medium or strong correlation). This is consistent with the longitudinal oblique motion of the prostate, and likely the effect from respiration on an organ confined within the genitourinary diaphragm with the rectum sitting posteriorly and bladder sitting superiorly. In all directions, the non-Gaussian distribution is more common for individual fraction, individual patient including all fractions, and all patients including all fractions. The spatial distribution of prostate motion shows an elongated shape in oblique direction, indicating a higher range of motion in the AP and SI directions. Conclusions: Our results showed that the prostate motion is highly correlated in AP and SI direction, indicating an oblique motion preference. In addition, the spatial distribution of prostate motion is elongated in an oblique direction, indicating that the organ motion dosimetric modeling using Gaussian kernel may need to be modified to account for the particular organ motion character of prostate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗