Search NASA⌕ Search

Engineering topics

Yao, M

Publications and source records attributed to Yao, M.

Structural Deformation of Sm@C 88 under High Pressure

We have studied the structural transformation of Sm@C 88 under pressure up to 18 GPa by infrared spectroscopy combined with theoretical simulations. The infrared-active vibrational modes of Sm@C 88 at ambient conditions have been assigned for the first time. Pressure-induced blue and red shifts of the corresponding vibrational modes indicate an anisotropic deformation of the carbon cage upon compression. We propose that the carbon cage changes from ellipsoidal to approximately spherical around 7 GPa. A smaller deformation of the carbon bonds in the area close to the Sm atom in the cage suggests that the trapped Sm atom plays a role in minimizing the compression of the adjacent bonds. Pressure induced a significant reduction of the band gap of the crystal. The HOMO-LUMO gap of the Sm@C 88 molecule decreases remarkably at 7 GPa as the carbon cage is deformed. Also, compression enhances intermolecular interactions and causes a widening of the energy bands. Both effects decrease the band gap of the sample. The carbon cage deforms significantly above 7 GPa, from spherical to a peanut-like shape and collapses at 18 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-404: Evaluation of the Effect of Spine Hardware for CyberKnife Spinal Stereotactic Radiosurgery

Purpose: Spine hardware made of high-Z materials such as titanium has the potential to affect the dose distribution around the metal rods in CyberKnife spinal stereotactic radiosurgery (SRS) treatments. The purpose of this work was to evaluate the magnitude of such effect retrospectively for clinical CyberKnife plans. Methods: The dose calculation was performed within the MultiPlan treatment planning system using the ray tracing (RT) and Monte Carlo (MC) method. A custom density model was created by extending the CT-to-Density table to titanium density of 4.5 g/cm3 with the CT number of 4095. To understand the dose perturbation caused by the titanium rod, a simple beam setup (7.5 mm IRIS collimator) was used to irradiate a mimic rod (5 mm) with overridden high density. Five patient spinal SRS cases were found chronologically from 2010 to 2015 in our institution. For each case, the hardware was contoured manually. The original plan was re-calculated using both RT and MC methods with and without rod density override without changing clinical beam parameters. Results: The simple beam irradiation shows that there is 10% dose increase at the interface because of electron backscattering and 7% decrease behind the rod because of photon attenuation. For actual clinical plans, the iso-dose lines and DVHs are almost identical (<2%) for calculations with and without density override for both RT and MC methods. However, there is a difference of more than 10% for D90 between RT and MC method. Conclusion: Although the dose perturbation around the metal rods can be as large as 10% for a single beam irradiation, for clinical treatments with complex beam composition the effect of spinal hardware to the PTV and spinal dose is minimal. As such, the MC dose algorithm without rod density override for CyberKnife spinal SRS is acceptable.

60 APPLIED LIFE SCIENCES↗

High-Pressure Studies on CeO2 Nano-Octahedrons with a (111)-Terminated Surface

In-situ high-pressure X-ray diffraction and Raman spectroscopies have been performed on well-shaped CeO{sub 2} nano-octahedrons enclosed by eight (111) planes. The CeO{sub 2} nano-octahedrons are shown to be more stable than their bulk counterparts and some other reported CeO{sub 2} nanocrystals of smaller size. The transition pressure from cubic to orthorhombic phase is approximately 10 GPa higher than that of 12 nm CeO{sub 2} nanocrystals even though they have similar volume expansion at ambient conditions. Additionally, the phase transition to {alpha}-PbCl2 phase is very sluggish and uncompleted even up to 55 GPa. The TEM image of the sample after decompression from 55 GPa clearly shows that the nano-octahedrons preserve the starting shape. Such distinct high-pressure behaviors in CeO{sub 2} nano-octahedrons have been discussed in terms of their special exposure surface. Further analysis shows that the lower compressibility of the exposed (111) planes in the nano-octahedrons is believed to be the major factor to the elevation of the phase transition pressure and the sluggishness of the transition.

36 MATERIALS SCIENCE↗

Interatomic Coulombic decay following Ne 1s Auger decay in NeAr

Using momentum-resolved electron-ion multicoincidence spectroscopy, we have investigated interatomic Coulombic decay (ICD) in the heteronuclear NeAr dimer following Ne 1s Auger decay. The measured intensity ratio for the three ICD transitions Ne{sup 2+}(2s{sup -1}2p{sup -1} {sup 1}P)Ar to Ne{sup 2+}(2p{sup -2} {sup 1}S)-Ar{sup +}(3p{sup -1}), Ne{sup 2+}(2s{sup -1}2p{sup -1} {sup 1}P)Ar to Ne{sup 2+}(2p{sup -2} {sup 1}D)-Ar{sup +}(3p{sup -1}), and Ne{sup 2+}(2s{sup -1}2p{sup -1} {sup 3}P)Ar to Ne{sup 2+}(2p{sup -2} {sup 3}P)-Ar{sup +}(3p{sup -1}) reasonably agree with predictions. The kinetic energy release distribution for the fragmentation to Ne{sup 2+}(2p{sup -2} {sup 1}D)-Ar{sup +}(3p{sup -1}) after the ICD transition from singlet Ne{sup 2+}(2s{sup -1}2p{sup -1} {sup 1}P)Ar state, which is a mirror image of the kinetic energy distribution of the emitted ICD electrons, suggests that the corresponding ICD rate is roughly two times lower than predicted by ab initio calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cold-target recoil-ion momentum spectroscopy for diagnostics of high harmonics of the extreme-ultraviolet free-electron laser light source at SPring-8

We have developed a cold-target recoil-ion momentum spectroscopy apparatus dedicated to the experiments using the extreme-ultraviolet light pulses at the free-electron laser facility, SPring-8 Compact SASE Source test accelerator, in Japan and used it to measure spatial distributions of fundamental, second, and third harmonics at the end station.

43 PARTICLE ACCELERATORS↗

Snapshots of Dynamics in Synthesizing N6-Isopentenyladenosine at the tRNA Anticodon

Bacterial and eukaryotic tRNAs that decode codons starting with uridine have a hydrophobically hypermodified adenosine at position 37 (A37) adjacent to the 3?-end of the anticodon, which is essential for efficient and highly accurate protein translation by the ribosome. However, it remains unclear as to how the corresponding tRNAs are selected to be modified by alkylation at the correct position of the adenosine base. We have determined a series of crystal structures of bacterial tRNA isopentenyltransferase (MiaA) in apo- and tRNA-bound forms, which completely render snapshots of substrate selections during the modification of RNA. A compact evolutionary inserted domain (herein swinging domain) in MiaA that exhibits as a highly mobile entity moves around the catalytic domain as likely to reach and trap the tRNA substrate. Thereby, MiaA clamps the anticodon stem loop of the tRNA substrate between the catalytic and swinging domains, where the two conserved elongated residues from the swinging domain pinch the two flanking A36 and A38 together to squeeze out A37 into the reaction tunnel. The site-specific isopentenylation of RNA is thus ensured by a characteristic pinch-and-flip mechanism and by a reaction tunnel to confine the substrate selection. Furthermore, combining information from soaking experiments with structural comparisons, we propose a mechanism for the ordered substrate binding of MiaA.

36 MATERIALS SCIENCE↗

Internalization of mesoporous silica nanoparticles induces transient but not sufficient osteogenic signals in human mesenchymal stem cells

The biocompatibility of nanoparticles is the prerequisite for their applications in biomedicine but can be misleading due to the absence of criteria for evaluating the safety and toxicity of those nanomaterials. Recent studies indicate that mesoporous silica nanoparticles (MSNs) can easily internalize into human mesenchymal stem cells (hMSCs) without apparent deleterious effects on cellular growth or differentiation, and hence are emerging as an ideal stem cell labeling agent. The objective of this study was to thoroughly investigate the effect of MSNs on osteogenesis induction and to examine their biocompatibility in hMSCs. Uptake of MSNs into hMSCs did not affect the cell viability, proliferation and regular osteogenic differentiation of the cells. However, the internalization of MSNs indeed induced actin polymerization and activated the small GTP-bound protein RhoA. The MSN-induced cellular protein responses as believed to cause osteogenesis of hMSCs did not result in promotion of regular osteogenic differentiation as analyzed by cytochemical stain and protein activity assay of alkaline phosphatase (ALP). When the effect of MSNs on ALP gene expression was further examined by reverse transcriptase polymerase chain reaction, MSN-treated hMSCs were shown to have significantly higher mRNA expression than control cells after 1-hour osteogenic induction. The induction of ALP gene expression by MSNs, however, was absent in cells after 1-day incubation with osteogenic differentiation. Together our results show that the internalization of MSNs had a significant effect on the transient protein response and osteogenic signal in hMSCs, thereby suggesting that the effects of nanoparticles on diverse aspects of cellular activities should be carefully evaluated even though the nanoparticles are generally considered as biocompatible at present.

60 APPLIED LIFE SCIENCES↗