Search NASA⌕ Search

Engineering topics

Yao, Wenxuan

Publications and source records attributed to Yao, Wenxuan.

At least 19 records

Development of Real-Time High-Density Pulsar Data Transmission and Processing for Grid Synchronization

Taking advantage of the extreme stability of the pulsar period, it can serve as the timing source for grid synchronization to compensate for the timing drift instigated by the loss of GPS signal. Nevertheless, the real-time transmission and processing of the pulsar data suffer from its high-frequency data rate, varying from megahertz to gigahertz, resulting in reduced computing speed and increased time delay. To mitigate this issue, the hardware and software frameworks are implemented for the high-density pulsar data transmission and processing for grid synchronization in this research. Initially, the high-density pulsar data is transferred using open-source software. The complementary duty cycle timing module is designed to coordinate the operation of the dual-channel high-speed interface and software. Subsequently, the multiple-threading is applied to the receiving, parsing, and splicing pulsar data. Next, the pulsar signal extraction method is implemented based on the polyphase filterbank and time of arrival estimation. Ultimately, real-time performance verification experiments are carried out for different components under two hardware platforms. Finally, the results demonstrate that only 0.482 s is required for processing 4 Gigabyte data through multiple-threading, which is 3.8 times faster than the single thread. The pulsar signal extraction can also be executed within 707 ms for 4.8 seconds of data, thereby indicating that real-time requirements can be met.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault-tolerant grid frequency measurement algorithm during transients

A system determines the frequency of grid signals corresponding to an electrical grid in real time. The system includes a transient detector that monitors a grid signal from a voltage meter or a current meter connected to the electrical grid. The system produces, in real time and at a sampling rate, a deviation signal indicative of a periodicity of the monitored grid signal. The system determines, over one or more cycles of the monitored grid signal, a measurement signal corresponding to the deviation signal. The system determines a frequency signal that corresponds a frequency estimation of the monitored signal by applying a frequency estimation when values of the measurement signal are less than a deviation threshold and maintaining the frequency signal at a constant value when values of the measured signal equal or exceeds the deviation threshold.

Zhan, Lingwei↗

Data-driven based coordinated smart inverter control for distributed energy resources

Smart inverters (SI) for distributed energy resources (DER) are becoming popular since they have the ability to stabilize as well as restore the voltage and frequency of power systems. Aiming at establishing the mathematical models combined with SI control methods, multiple optimization methods are developed. However, the computational complexity of solving such a mathematical model with various uncertainties limits the real-time application of the SI control. To conquer this challenge, a data-driven-based SI control approach is developed to achieve coordinated control in the high penetration DER system. First, an optimization problem for maximizing the active power generation and minimizing the power loss is designed using the Volt/VAR control. To reduce the time consumption, the recurrent neural network (RNN) is proposed to model the relationship between the uncertainties and control actions during the offline site. The RNN with different sub-structures such as the long short-term memory cell and gated recurrent unit cell are included to enrich the diversity of features. In the last stage, different experiment comparisons, including multiple uncertainties maps and stateof- art machine learning methods, are conducted to verify the effectiveness of the proposed method based on the IEEE 123 bus power system. The results demonstrate that the proposed method can effectively achieve a rapid and coordinated control with a lower error rate.

Qiu, Wei↗

Intensity Modulated Fiber Optic Sensor: A Novel Grid Measurement Unit

This paper presents a novel approach to physical displacement-based power grid measuring via an Intensity Modulated Fiber Optic Sensor (IMFOS). An IMFOS utilizes one fiber to transmit the intensity modulation light from its Electro-Optic controller to a fiber optic probe. The power grid voltage and current can induce physical displacements in transducers via the piezoelectric effect and the Lorentz law, respectively, which then result in a distance change between the optical probe and the reflective surface of the transducers. In parallel, multiple fibers are used to collect the reflective light for electro-optic conversion. Furthermore, a National Instruments-based characterization platform is set up for performance evaluation. Here, the testing result demonstrates that the IMFOS is immune to the inherent DC and low-frequency saturation issues prevalent in conventional potential and current transformers. Finally, the IMFOS is implemented in a Universal Grid Analyzer to illustrate its applicability for phasor estimation in actual power grids.

42 ENGINEERING↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Experiment-based Distribution Level Performance Comparison among PMUs

This paper presents a experiment-based distribution level performance comparison among three Phasor Measurement Units (PMUs). Several evaluation criteria, including the total vector error, the phase angle error, the frequency error, the rate of change of frequency, the response time, the settling time, the overshoot, and the algorithm window size, are selected to compare the static and dynamic performances of the PMUs under steady state and step response test conditions. In order to have a more realistic test environment, a test is setup in which PMUs under evaluation have exactly the same input signals. The quantitative experiment result analysis gives an end-user guideline to the PMU selection regarding distribution level applications.

Yin, He↗

Cyber-Attack Identification of Synchrophasor Data Via VMD and Multifusion SVM

A large amount of synchrophasor data in the wide area measurement system (WAMS) needs to be collected and transmitted to the phasor data concentrator, thereby increasing the possibility of being attacked by hackers. The attacked data are therefore hidden into the normal synchrophasor data so that the synchrophasor data based application will be affected. To remedy this problem, an identification framework is proposed to detect the data cyber-attack in WAMS utilizing variational mode decomposition (VMD) and multifusion support vector machine (MSVM). First, VMD is used to transform the attacked data into multiple modal components. Thereafter, a novel MSVM is employed to classify the deterministic features using the proposed linear combined multikernel (LCM). Further, this LCM can fuse multiple types of features, including the time, frequency, and statistical domains of the synchrophasor data. Utilizing the actual data from FNET/GridEye, different experiments are conducted under multiple attack strengths and types. The results demonstrate that the identification framework has higher precision and robustness compared with other conventional classifiers.

97 MATHEMATICS AND COMPUTING↗

Pulsar-Calibrated Timing Source for Synchronized Sampling

The Global Positioning System (GPS) is critical to the real-time synchronized sampling of phasor measurement units (PMUs). Unfortunately, GPS signals are occasionally unstable due to several factors such as weak satellite signal and GPS spoofing, thereby leaving the PMU with a degraded sampling performance. In this letter, a novel Pulsar-calibrated Timing Source (PTS) is proposed as the alternative timing source for synchronized sampling. Further, the PTS can generate the timing signal with a 1 μs drift error within 91 holdover minutes to ensure continuity of sampling accuracy. Experimental tests are conducted and the results reveal the reliability and accuracy of the PTS for PMU synchronization.

42 ENGINEERING↗

Online Detection of Low-Quality Synchrophasor Data Considering Frequency Similarity

Here, this letter proposes a new approach for online detection of low-quality synchrophasor data under both normal and event conditions. The proposed approach utilizes the features of synchrophasor data in time and frequency domains to distinguish multiple regional PMU signals and detect low-quality synchrophasor data. It is more effective to detect low-quality data with apparently indistinguishable profiles. Case studies from recorded synchrophasor measurements verify the effectiveness of the proposed approach for detecting low-quality synchrophasor data in frequency, voltage magnitude and voltage angle.

42 ENGINEERING↗

Tampering detection and location identification of digital audio recordings

Systems and methods for detecting a tampering and identifying a location of a digital recording are provided. A frequency sequence and a phase angle sequence may be extracted from the digital recording. A portion of the frequency sequence may be matched to one of a plurality of reference frequency sequences, and a portion of the phase angle sequence may be matched to one of a plurality of reference phase angle sequences. Tampering of the digital recording may be detected when the frequency and phase sequences differ from the matched reference sequences. Moreover, a noise sequence may be extracted from the extracted frequency sequence. A location of the digital recording may be identified by matching the noise sequence to one of a plurality of noise sequences of the plurality of reference frequency sequences.

Chai, Jidong↗

Time-frequency based cyber security defense of wide-area control system for fast frequency reserve

Global power systems are transiting from conventional fossil fuel energy to renewable energies due to their environmental benefits. The increasing penetration of renewable energies presents challenges for power system operation. The efficiency and sufficiency of responsive reserves have become increasingly important for power systems with a high proportion of renewable energies. The Fast Frequency Reserve (FFR), especially the Wide-area Monitoring System (WAMS)-based FFR, is a promising and effective solution to secure and enhance the stability of power systems. However, cyber security has become a new challenge for the WAMS-based FFR system. Cyber attacks on the FFR control system may threaten the safety of power system operation due to the rapid power controllability requirement of FFR. Therefore, to address this problem, a time-frequency based cyber security defense framework is proposed to detect the cyber spoofing of synchrophasor data in WAMS-based FFR control systems. This paper first introduces the Continuous Wavelet Transforms (CWTs) to decompose spoofing signals. Then, the Dual-frequency Scale Convolutional Neural Networks (DSCNN) is proposed to identify the time-frequency domains matrix from two frequency scales. Integrating CWTs and DSCNN, an identification framework called CWTs-DSCNN is further proposed to detect the spoofing attacks in the WAMS-based FFR system. Multiple experiments using the actual data from FNET/GridEye are performed to verify the effectiveness of the framework in securing WAMS-based FFR systems.

25 ENERGY STORAGE↗

Frequency Injection Based HVDC Attack-Defense Control Via Squeeze-Excitation Double CNN

Due to the independent controllability and fast power regulation capability, the High Voltage Direct Current (HVDC) system could be a prospective technology to provide multiple ancillary services to the system besides conventional bulk power transmission. However, with the increase of False Data Injection Attacks (FDIAs) on PMU data, the HVDC system could have the wrong response once the collected data that the HVDC system relied on is attacked, thus threatening the system operating security. How to ensure the security of the PMU-based HVDC ancillary service control become an urgent issue. To mitigate the risk, this paper proposed an HVDC attack-defense control based on the FDIAs detection method. Firstly, the Squeeze-Excitation based Double Convolutional Neural Networks (SE-DCNN) is proposed to realize fast identification of the attacking frequency type based on the time and frequency domain signals. Furthermore, the duration time of FDIAs is detected by the local outlier factor. Then, utilizing the results from SE-DCNN, HVDC ancillary service control framework is reorganized and an HVDC attack defense control is proposed for suppressing the potential influence of various types of FDIAs on the HVDC system ancillary service. Different experiments results demonstrate that the proposed method has the ability to significantly mitigate the frequency deviation and oscillation under the FDIA.

42 ENGINEERING↗

Data source authentication of synchrophasor measurement devices based on 1D-CNN and GRU

Synchrophasor measurement devices (SMDs) have been widely deployed to support real-time monitoring and control of power systems. In the meantime, data spoofing has emerged in recent years. Therefore, it is of great importance to study data authentication algorithms for detecting and defending the data spoofing effectively. Here, a one-dimensional convolutional neural network (1D-CNN) is utilized to extract temporal signatures hidden in frequency, voltage angle and amplitude data; then the gated recurrent unit (GRU) employs these temporal signatures for data source authentication. In case studies, the performances of different algorithms are tested in large-scale power systems with numerous SMDs for the first time, and comparisons among different algorithms show that the proposed algorithm can achieve a higher accuracy of data source authentication with a shorter time window.

47 OTHER INSTRUMENTATION↗

Synchrophasor Data Compression Under Disturbance Conditions via Cross-Entropy-Based Singular Value Decomposition

The increasing deployment of phasor measurement units and the advances of their reporting rates are challenging the present data centers in terms of storing and analyzing large-volume data. Under power system disturbance conditions, it is difficult to retain critical information while compressing the synchrophasor data effectively. This article combines the cross entropy and the singular value decomposition, proposing a novel model to compress the synchrophasor data to an extremely small size yet keep superior accuracy. The proposed model is extensively tested and compared with the state-of-the-art algorithms using the simulated and the FNET/GridEye field-collected data. The result indicates that the proposed algorithm has superior performance in compressing the data while retaining critical information under disturbance conditions.

42 ENGINEERING↗

Hybrid Data-Driven Based HVdc Ancillary Control for Multiple Frequency Data Attacks

The high voltage direct current (HVdc) intertie has been applied to provide ancillary-services for ac grids, utilizing the real-time feedback from phasor measurement units (PMUs). However, PMU data communication is vulnerable to false data injection attacks (FDIA) due to protocol defects, thus the HVdc ancillary control and system stability will be threatened. To address this issue, this article proposes a novel HVdc control strategy based on a hybrid data-driven (HDD) methodology. In this work, the HDD methodology is first proposed to detect the types and duration time of multiple frequency attacks. Specifically, the Hilbert Huang transform (HHT) is used to decompose the frequency data, using variational mode decomposition instead of the traditional empirical mode decomposition, to extract data features. Second, a multikernel support vector machine is proposed to classify the attacked data based on the designed distinctive features from HHT. Meanwhile, the attacking duration time is decided using an unsupervised technique. Third, an HDD-based HVdc ancillary control strategy is established to eliminate the effect of FDIAs on the HVdc frequency response. Comprehensive experiments of HDD-based HVdc ancillary controls under different FDIAs suggest that the proposed HDD could fast and accurately classify the FDIAs, and the HDD-based HVdc ancillary control strategy could significantly suppress the impact of the FDIAs.

97 MATHEMATICS AND COMPUTING↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗

Pulsar Based Timing for Grid Synchronization

Existing synchronization systems in the power grid, such as the global positioning system, are susceptible to temporary or permanent failures due to various unpredictable and uncontrollable factors such as cyber-attack and electromagnetic interferences, thus affecting the accuracy and reliability of generated timing signal. In this article, a pulsar astronomy-based timing system is proposed to provide an alternative synchronization signal. Further, this clock will offer significant security improvements to power grid applications, such as a wide-area monitoring system, which depends on a precise timing signal. The hardware and software frameworks are described in detail. First, a high-speed sampling hardware platform is designed to collect signals from radio telescopes. Then a periodic pulse extraction method with three steps is proposed to process the pulsar signal, including polyphase filterbanks, incoherent de-dispersion, and sliding window folding. Lastly, three experiments are conducted to verify the effectiveness of the frameworks. The generated pulsar timing pulse is presented, and the factors affecting its accuracy are also discussed. The analysis results demonstrate that the pulsar signals can provide high-accurate timing pulses for grid synchronization.

24 POWER TRANSMISSION AND DISTRIBUTION↗