Search NASA⌕ Search

Engineering topics

Ye, J.

Publications and source records attributed to Ye, J..

Design and Testing of the Endcap Concentrator ASICs for the CMS High-Granularity Calorimeter Upgrade

A major upgrade of the High-Granularity Calorimeter (HGCAL) in the CMS detector is planned for Long-Shutdown 3 (LS3), currently expected to start in 2026. This upgrade will contain over 6 million channels and the electronics will be required to be low power and to withstand a radiation environment with a High-Energy Hadron flux of 3x10**6 particles per square centimeter per second. The solution to this significant challenge is the two Endcap Concentrator (ECON) ASICs, ECON-T and ECON-D, working in tandem with the HGCROC front-end ASIC. The two ECON ASICs provide critical on-detector data reduction for both the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs are fabricated in 65nm CMOS. They are rad-tolerant to 600 Mrad with low power consumption (<2.5 mW/channel). This presentation will be a comprehensive description of each ECON design, including the infrastructure that they share as well as the elements that make each unique. The presentation will also include functionality and radiation tests for both ASICs, and the first high statistics characterization results from the full production of 75k ECON-D and ECON-T ASICs.

Hoff, James R. [Fermilab] (ORCID:0000000163514592)↗

GBT20, a 20.48 Gbps PAM4 Optical Transmitter Module for Particle Physics Experiments

We present a pluggable radiation-tolerant 4-level Pulse-Amplitude-Modulation (PAM4) optical transmitter module called GBT20 (Giga-Bit Transmitter at 20 Gbps) for particle-physics experiments. GBT20 has an OSFP or firefly connector to input 16-bit data each at 1.28 Gbps. The GBT20 drives a VCSEL die with an LC lens or a VCSEL TOSA and interfaces an optical fiber with a standard LC connector. The minimum module, including the host connector, occupies 41 mm x 13 mm x 6 mm. At 20.48 Gbps, the minimum Transmitter Dispersion Eye Closure Quaternary (TDECQ) is around 0.7 dB. The power consumption is around 164 mW in the low-power mode. The SEE cross-section is below 7.5x10^(-14) cm^2. No significant performance degrades after a TID of 5.4 kGy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An FPGA-based readout chip emulator for the CMS ETL detector upgrade

Here, we present an FPGA-based readout chip emulator board for the CMS Endcap Timing Layer (ETL) detector upgrade. The emulator board uses an Intel Cyclone 10 GX FPGA to emulate the digital functions of four Endcap Layer Readout Chips (ETROCs). Based on the actual ETROC design, the firmware is implemented and verified. The emulator board is being used for the ETROC digital design verification and system development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design and test results of A Giga-Bit Cable Receiver (GBCR) for the ATLAS Inner Tracker Pixel Detector

This paper presents the design and test results of a Gigabit Cable Receiver ASIC called GBCR for the HL-LHC upgrade of the ATLAS Inner Tracker (ITk) pixel detector. Three prototypes (GBCR1, GBCR2, and GBCR3) have been designed in the CERN-identified 65 nm CMOS technology. GBCR receives seven (GBCR2) or six (GBCR3) channels (RX) each at 1.28 Gbps from the front-end readout chip RD53B via flex cables up to 1 meter and Twinax cables up to 5 meters and sends the equalized and retimed signals to lpGBT. Both GBCR2 and GBCR3 ASICs have two transmitting channels (TX) that pre-emphasize the signals from lpGBT before sending them to RD53B through the same cables. No Single-Event Upset (SEU) is observed in any tested channels of GBCR2 in a 400 MeV proton beam. The extrapolated bit error rate for the future HL-LHC application is below 8*10^(-16), significantly below the specified BER criterion. GBCR3 is designed to improve the immunity to single-event-upset by applying the Triple Modular Redundancy (TMR) technology to all RX channels. The retimed signals from GBCR3 have less total jitter than those from GBCR2 (35 ps versus 79 ps). Each receiver channel of GBCR3 consumes 75% more power than that of GBCR2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TDC with uncontrolled delay lines: calibration approaches and precision improvement methods

The time-to-digital-converter (TDC) using uncontrolled delay lines has a simple structure and finer measurement precision since the delay cells are pure digital gates that operate at maximum speed. For every incoming hit, two “snapshots” of the delay line are taken by the register array with two strobes separated with a known time interval. With two measurements, propagation delays of each cell in the delay line can be calibrated for the operating temperature and voltage. The two measurements can also be averaged to improve the TDC measurement precision. We will discuss various calibration approaches and present test results in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high-resolution clock phase shifter circuitry for ALTIROC

Abstract A high-resolution clock phase shifter is implemented to adjust the phase of multiple clocks at 40 MHz, 80 MHz, or 640 MHz in the ALTIROC chip. The phase shifter has a coarse-phase shifter and a fine-phase shifter to achieve a step size of 97.7 ps and an adjustable range of 25 ns. The fine delay unit is based on a Delay Locked Loop (DLL) operating at 640 MHz. The phase shifter is fabricated in a 130 nm CMOS process. The area of the phase shifter is 725 µm × 248 µm. The Differential Non-Linearity (DNL) and the Integral Non-Linearity (INL) are ±0.6 LSB and ±0.75 LSB, respectively. The jitter from −25 °C to 20 °C is less than 15.5 ps (RMS), including the contributions from the FPGA clock source and the PLL. The power consumption is 11.2 mW.

Instruments & Instrumentation↗

Tungsten doped diamond shells for record neutron yield inertial confinement fusion experiments at the National Ignition Facility

We report on fabrication and characterization of layered, tungsten doped, spherical about 2 mm diameter microcrystalline diamond ablator shells for inertial confinement fusion (ICF) experiments at the National Ignition Facility. As previously reported, diamond ICF ablator shells can be fabricated by chemical vapor deposition (CVD) on solid spherical silicon mandrels using an ellipsoidal microwave plasma reactor. In the present work, we further developed these ablator shells by embedding a W -doped diamond layer sandwiched between two undoped diamond regions. W incorporation in diamond was achieved by adding tungsten hexacarbonyl to the CH 4 /H 2 CVD feed gas. We observe that the W doping concentration decreases with increasing deposition rate which, in turn, is controlled by adjusting the total gas pressure. Cross sectional microstructural analysis reveals sharp interfaces between doped and undoped regions of the diamond shell and uniform W distribution with concentrations up to about 0.3 at.%. At higher W concentrations (>0.3 at.%) formation of tungsten carbide precipitates is observed. Using a 3-shock 1.6 MJ laser pulse, the targets described in this work produced the first laser driven implosion to break the 1 × 10 16 neutron yield barrier, followed by experiments (described in future publications) with similar targets and slightly more laser energy producing yields as high as 4 × 10 17 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vehicle Technology Office Battery Project (FY22Q4 Quarterly Report)

The project has two primary objectives: (1) down select three-dimensional (3D) printing and post-processing approaches for solid-state electrolyte (SSE) / cathode integration, and (2) understand battery failure mechanisms via ex situ and in situ characterization.

25 ENERGY STORAGE↗

VTO FY2022 Q3 (Quarterly Report)

The project has two primary objectives: (1) down select three-dimensional (3D) printing and post-processing approaches for SSE/cathode integration, and (2) understand battery failure mechanisms via ex situ and in situ characterization.

36 MATERIALS SCIENCE↗

QTIA, a 2.5 or 10 Gbps 4-channel array optical receiver ASIC in a 65 nm CMOS technology

Here, the Quad transimpedance and limiting amplifier (QTIA) is a 4-channel array optical receiver ASIC, developed using a 65 nm CMOS process. It is configurable between the bit rate of 2.56 Gbps and 10 Gbps per channel. QTIA offers careful matching to both GaAs and InGaAs photodiodes. At this R&D stage, each channel has a different biasing scheme to the photodiode for optimal coupling. A charge pump is implemented in one channel to provide a higher reverse bias voltage, which is especially important to mitigate radiation effects on the photodiodes. The circuit functions of QTIA successfully passed the lab tests with GaAs photodiodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VTO battery project FY2022 Q2 (Quarterly Report)

The project has two primary objectives: (1) down select three-dimensional (3D) printing and post-processing approaches for SSE/cathode integration, and (2) understand battery failure mechanisms via ex situ and in situ characterization.

36 MATERIALS SCIENCE↗

A radiation tolerant clock generator for the CMS endcap timing layer readout chip

Here, we present the test results of a low jitter Phase Locked Loop (PLL) prototype chip for the CMS Endcap Timing Layer readout chip (ETROC). This chip is based on the improved version of a clock synthesis circuit named ljCDR from the Low Power Gigabit Transceiver (lpGBT) project. The ljCDR is tested in its PLL mode. An automatic frequency calibration (AFC) block with the Triple Modular Redundancy (TMR) register is developed for the LC-oscillator calibration. The chip was manufactured in a 65 nm CMOS process with 10 metal layers. The chip has been extensively tested, including Total Ionizing Dose (TID) testing up to 300 Mrad and Single Event Upset (SEU) testing with heavy ions possessing a Linear Energy Transfer (LET) from 1.3 to 62.5 MeV × cm 2 /mg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 40 Gbps Optical Transceiver for Particle Physics Experiments

We present the design and the test results of a quad-channel optical transceiver module (QTRx) possibly for future particle physics experiments. The transmitters of QTRx, each at 10 Gbps, are based on a Quad-channel VCSEL Diode array Driver (QLDD) and 1 x 4 VCSEL array. The receivers of QTRx, with data rates of 2.56 Gbps or 10 Gbps per channel, are based on a Quad-channel Trans-Impedance and limiting Amplifier (QTIA) and 1 x 4 photodiode array of GaAs or InGaAs. QTRx is 20 mm x 10 mm x 5 mm and couples to an MT fiber connector. Test results indicate that QTRx achieves the design goals with a power consumption of 124 mW per transmitter channel at 10 Gbps and 120 mW at 2.56 Gbps for the receiver channel with an on-chip charge pump. The sensitivities of QTIA are -17 dBm at 2.56 Gbps and -8 dBm at 10 Gbps, respectively. Further improvements with a gold-finger interface and a more compact optical lens are being designed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗