Search NASA⌕ Search

Engineering topics

Ye, Z.

Publications and source records attributed to Ye, Z..

Performance of Pixel and Strip AC-LGAD Sensors with Different Design Parameter on a 120 GeV Proton Beam

We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20- μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

Lara, Carlos Pérez↗

Electroproduction of the Λ/Σ 0 hyperons at Q 2 ≃ 0.5 (GeV/c) 2 at forward angles

In 2018, the E12-17-003 experiment was conducted at the Thomas Jefferson National Accelerator Facility (JLab) to explore the possible existence of an nn⁢Λ state in the reconstructed missing mass distribution from a tritium gas target [K. N. Suzuki et al., Prog. Theor. Exp. Phys. 2022, 013D01 (2022); B. Pandey et al., Phys. Rev. C 105, L051001 (2022)]. As part of this investigation, data were also collected using a gaseous hydrogen target, not only for a precise absolute mass scale calibration but also for the study of Λ/Σ 0 electroproduction. This dataset was acquired at Q 2 ≃ 0.5 (GeV/c) 2 , W = 2.14 GeV, and θ$^{c.m.}_{γK}$ ≃ 8°. It covers forward angles where photoproduction data are scarce and a low-Q 2 region that is of interest for hypernuclear experiments. On the other hand, this kinematic region is at a slightly higher Q 2 than previous hypernuclear experiments, thus providing crucial information for understanding the Q 2 dependence of the differential cross sections for Λ/Σ 0 hyperon electroproduction. Here, this paper reports on the Q 2 dependence of the differential cross section for the e + p → e' + K + + Λ/Σ 0 reaction at 0.2–0.8 (GeV/c) 2 , and provides comparisons with the currently available theoretical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The solenoidal large intensity device (SoLID) for JLab 12 GeV

The solenoidal large intensity device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensity frontier that will exploit the full potential of its 12 GeV electron beam. In this paper, we present an overview of the rich physics program that can be realized with SoLID, which encompasses the tomography of the nucleon in 3D momentum space from semi-inclusive deep inelastic scattering, expanding the phase space in the search for new physics and novel hadronic effects in parity-violating DIS, a precision measurement of J/ψ production at threshold that probes the gluon field and its contribution to the proton mass, tomography of the nucleon in combined coordinate and momentum space with deep exclusive reactions, and more. To meet the challenging requirements, the design of SoLID described here takes full advantage of recent progress in detector, data acquisition and computing technologies. In addition, we outline potential experiments beyond the currently approved program and discuss the physics that could be explored should upgrades of CEBAF become a reality in the future.

3D imaging↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 μm and 32 ps resolutions from strips of 1 cm length and 500 μm pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

47 OTHER INSTRUMENTATION↗

Determining the gluonic gravitational form factors of the proton

The proton is one of the main building blocks of all visible matter in the Universe. Among its intrinsic properties are its electric charge, mass and spin. These properties emerge from the complex dynamics of its fundamental constituents—quarks and gluons—described by the theory of quantum chromodynamics. The electric charge and spin of protons, which are shared among the quarks, have been investigated previously using electron scattering. An example is the highly precise measurement of the electric charge radius of the proton. By contrast, little is known about the inner mass density of the proton, which is dominated by the energy carried by gluons. Gluons are hard to access using electron scattering because they do not carry an electromagnetic charge. Here we investigated the gravitational density of gluons using a small colour dipole, through the threshold photoproduction of the J/ψ particle. We determined the gluonic gravitational form factors of the proton from our measurement. Here we used a variety of models and determined, in all cases, a mass radius that is notably smaller than the electric charge radius. In some, but not all cases, depending on the model, the determined radius agrees well with first-principle predictions from lattice quantum chromodynamics. This work paves the way for a deeper understanding of the salient role of gluons in providing gravitational mass to visible matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of the titanium spectral function from ($e,e'p$) data

The E12-14-012 experiment, performed in Jefferson Lab Hall A, has measured the (e, e'p) cross section in parallel kinematics using a natural titanium target. In this paper, we report the analysis of the dataset obtained in different kinematics for our solid natural titanium target. Data were obtained in a range of missing momentum and missing energy between 15 ≲ p m ≲ 250 MeV / c and 12 ≲ E m ≲ 80 MeV, respectively, and using an electron beam energy of 2.2 GeV. We measured the reduced cross section with ~7% accuracy as a function of both missing momentum and missing energy. Furthermore, our Monte Carlo simulation, including both a model spectral function and the effects of final-state interactions, satisfactorily reproduces the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The influences of the galactic cosmic ray on the atmospheric ozone

The relationship between the yearly variations of cosmic ray intensity and ozone in the atmosphere, and the ozone disturbance initiated by the Forbush decrease of 1965-1976 is analyzed. The data on cosmic ray intensity were selected from the records of the super neutron monitor at Deep River station and the ionization chamber at Beijing station. Ozone data were taken from Resolute (Canada), Bismark (N. Dakota, USA), Kagoshima (Japan), and Kodaikanal (India). The statistical results show that ozone is prominently modulated and disturbed by the 11 year variation and the Forbush decrease in the galactic cosmic ray.

Ye, Z.↗