Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a 83 mKr source for the calibration of the CENNS-10 liquid argon detector

We report on the preparation of and calibration measurements with a 83 mKr source for the CENNS-10 liquid argon detector. 83 mKr atoms generated in the decay of a 83 Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of 83 mKr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9% at the total 83 mKr decay energy of 41.5 keV. Lastly, we performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV.

47 OTHER INSTRUMENTATION↗

First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon

We report the first measurement of coherent elastic neutrino-nucleus scattering (CEvNS) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer CEvNS over the background-only null hypothesis with greater than 3σ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2±0.7)×10 –39 cm 2 —consistent with the standard model prediction. In conclusion, the neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the CEvNS process and provides improved constraints on nonstandard neutrino interactions.

39 ≤ A ≤ 58↗

The radioactive source calibration system of the PROSPECT reactor antineutrino detector

The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment created to search for sterile neutrinos with a mass on the order of 1 eV/c 2 and to measure the spectrum of electron antineutrinos from a highly-enriched 235 U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in 6 Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. Here, we describe the design, operation, and performance of the PROSPECT source calibration system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Antineutrino Spectrum from U 235 Fission at HFIR with PROSPECT

This Letter reports the first measurement of the 235 U ν¯ e energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW th highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678 ± 304 (stat.) ν¯ e -induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to 235 U. Despite broad agreement, comparison of the Huber 235 U model to the measured spectrum produces a χ 2 /ndf = 51.4/31, driven primarily by deviations in two localized energy regions. As a result, the measured 235 U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the ν¯ e energy region of 5-7MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A low mass optical grid for the PROSPECT reactor antineutrino detector

PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a shortbaseline reactor antineutrino experiment designed to provide precision measurements of the 235U product $\overline{v}$ e spectrum, utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT’s segmentation system, the optical grid, plays a central role in reconstructing the position and energy of $\overline{v}$ e interactions in the detector. This paper is the technical reference for this PROSPECT subsystem, describing its design, fabrication, quality assurance, transportation, and assembly in detail. In addition, the dimensional, optical and mechanical characterizations of optical grid components and the assembled PROSPECT target are also presented. The technical information and characterizations detailed here will inform geometry-related inputs for PROSPECT physics analysis and can guide a variety of future particle detection development efforts, such as those using optically reflecting materials or filament-based 3D printing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lithium-loaded liquid scintillator production for the PROSPECT experiment

This work reports here the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT) . Fifty-nine 90 liter batches of LiLS ( 6 Li mass fraction 0.082%±0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a pure liquid scintillator reference, and pulse shape discrimination capability. Fifty-seven batches passed the quality assurance criteria and were used for the PROSPECT experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The PROSPECT reactor antineutrino experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented 6 Li-doped liquid scintillator detector for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT is a movable 4-ton antineutrino detector covering distances of 7 m to 13 m from the High Flux Isotope Reactor core. It will probe the best-fit point of the v¯ e disappearance experiments at 4 σ in 1 year and the favored regions of the sterile neutrino parameter space at more than 3σ in 3 years. PROSPECT will test the origin of spectral deviations observed in recent θ 13 experiments, search for sterile neutrinos, and address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly. This study describes the design, construction, and commissioning of PROSPECT and reports first data characterizing the performance of the PROSPECT antineutrino detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep neural networks for energy and position reconstruction in EXO-200

Here, we apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters—total energy and position—directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.

97 MATHEMATICS AND COMPUTING↗

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗