Search NASA⌕ Search

Engineering topics

Yeung, Edward S

Publications and source records attributed to Yeung, Edward S.

Electrophoretic Migration and Axial Diffusion of Individual Nanoparticles in Cylindrical Nanopores

Membranes with straight, vertical nanopores have found widespread applications in chemical and biological sciences, including separation, detection, catalysis, and drug delivery. They can also serve as a model system to understand molecular behavior and fundamental mechanisms of separation, bridging the gap between conventional model systems such as flat surfaces and real chromatographic stationary phases such as micrometer-sized porous particles. We recently found that the axial motion of individual biomolecules inside nanopores can be significantly slower than in bulk solution. This suggests that either chromatographic adsorption was present and/or the viscosity inside the nanopores was unusually high. In this study, we measured the electrophoretic motion as well as the axial diffusion of individual nanoparticles in cylindrical alumina nanopores. We found that the electrophoretic mobilities and the diffusion coefficients of polystyrene nanoparticles were both substantially smaller compared to bulk solution independent of particle size or pore diameter. The results imply that the apparent solution viscosity in nanodomains is anomalous.

36 MATERIALS SCIENCE↗

Use of Mass spectrometry for imaging metabolites in plants

We discuss and illustrate recent advances that have been made to image the distribution of metabolites among cells and tissues of plants using different mass spectrometry technologies. These technologies include matrix-assisted laser desorption ionization, desorption electrospray ionization, and secondary ion mass spectrometry. These are relatively new technological applications of mass spectrometry and they are providing highly spatially resolved data concerning the cellular distribution of metabolites. We discuss the advantages and limitations of each of these mass spectrometric methods, and provide a description of the technical barriers that are currently limiting the technology to the level of single-cell resolution. However, we anticipate that advances in the next few years will increase the resolving power of the technology to provide unprecedented data on the distribution of metabolites at the subcellular level, which will increase our ability to decipher new knowledge concerning the spatial organization of metabolic processes in plants.

36 MATERIALS SCIENCE↗

In Situ Probing of Cholesterol in Astrocytes at the Single Cell Level using Laser Desorption Ionization Mass Spectrometric Imaging with Colloidal Silver

Mass spectrometric imaging has been utilized to localize individual astrocytes and to obtain cholesterol populations at the single-cell level in laser desorption ionization (LDI) with colloidal silver. The silver ion adduct of membrane-bound cholesterol was monitored to detect individual cells. Good correlation between mass spectrometric and optical images at different cell densities indicates the ability to perform single-cell studies of cholesterol abundance. The feasibility of quantification is confirmed by the agreement between the LDI-MS ion signals and the results from a traditional enzymatic fluorometric assay. We propose that this approach could be an effective tool to study chemical populations at the cellular level.

47 OTHER INSTRUMENTATION↗

High-Spatial and High-Mass Resolution Imaging of Surface Metabolites of Arabidopsis thaliana by Laser Desorption-Ionization Mass Spectrometry Using Colloidal Silver

High-spatial resolution and high-mass resolution techniques are developed and adopted for the mass spectrometric imaging of epicuticular lipids on the surface of Arabidopsis thaliana. Single cell level spatial resolution of {approx}12 {micro}m was achieved by reducing the laser beam size by using an optical fiber with 25 {micro}m core diameter in a vacuum matrix-assisted laser desorption ionization-linear ion trap (vMALDI-LTQ) mass spectrometer and improved matrix application using an oscillating capillary nebulizer. Fine chemical images of a whole flower were visualized in this high spatial resolution showing substructure of an anther and single pollen grains at the stigma and anthers. The LTQ-Orbitrap with a MALDI ion source was adopted to achieve MS imaging in high mass resolution. Specifically, isobaric silver ion adducts of C29 alkane (m/z 515.3741) and C28 aldehyde (m/z 515.3377), indistinguishable in low-resolution LTQ, can now be clearly distinguished and their chemical images could be separately constructed. In the application to roots, the high spatial resolution allowed molecular MS imaging of secondary roots and the high mass resolution allowed direct identification of lipid metabolites on root surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral imaging of single molecules by transmission grating-based epi-fluorescencs microscopy

A spectral imaging method of single protein molecules labeled with a single fluorophore is presented. The method is based on a transmission grating and a routine fluorescence microscope. The bovine serum albumin (BSA) and antiBSA molecules labeled with Alexa Fluor 488 and Alexa Fluor 594, respectively, are used as the model proteins. The fluorescence of single molecules is dispersed into zeroth-order spectrum and first-order spectrum by the transmission grating. Results show that the fluorescence emission spectrum of single molecule converted from the first-order spectral imaging is in good agreement with the bulk fluorescence spectrum. The spectral resolution of 2.4 nm/pixel is obtained, which is sufficient for identifying the molecular species in a multicomponent system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ndocytosis of a Single Mesoporous Silica Nanoparticle into a Human Lung Cancer Cell Observed by Differential Interference Contrast Microscopy

The unique structural features of mesoporous silica nanoparticles (MSN) have made them very useful in biological applications, such as gene therapy and drug delivery. Flow cytometry, confocal microscopy, and electron microscopy have been used for observing the endocytosis of MSN. However, flow cytometry cannot directly observe the process of endocytosis. Confocal microscopy requires fluorescence labeling of the cells. Electron microscopy can only utilize fixed cells. In the present work, we demonstrate for the first time that differential interference contrast (DIC) microscopy can be used to observe the entire endocytosis process of MSN into living human lung cancer cells (A549) without fluorescence staining. There are three physical observables that characterize the locations of MSN and the stages of the endocytosis process: motion, shape, and vertical position. When it was outside the cell, the MSN underwent significant Brownian motion in the cell growth medium. When it was trapped on the cell membrane, the motion of the MSN was greatly limited. After the MSN had entered the cell, it resumed motion at a much slower speed because the cytoplasm is more viscous than the cell growth medium and the cellular cytoskeleton networks act as obstacles. Moreover, there were shape changes around the MSN due to the formation of a vesicle after the MSN had been trapped on the cell membrane and prior to entry into the cell. Finally, by coupling a motorized vertical stage to the DIC microscope, we recorded the location of the MSN in three dimensions. Such accurate 3D particle tracking ability in living cells is essential for studies of selectively targeted drug delivery based on endocytosis.

59 BASIC BIOLOGICAL SCIENCES↗

Linkage Position and Residue Identification of Disaccharides by Tandem Mass Spectrometry and Linear Discriminant Analysis

The discrimination of isomeric disaccharides with different linkage types and different monosaccharide residues--glucose (Glc), galactose (Gal), and mannose (Man) at the non-reducing end - was investigated with tandem mass spectrometry (MS/MS) and linear discriminant analysis (LDA). Conventional matrix-assisted laser desorption/ionization (MALDI)-MS has strong interference peaks from matrix ions in the low mass region (<500 Da). This greatly limits the application of MALDI-MS for the analysis of small molecules such as saccharides. We solved this problem by using LDI with acidic fullerene matrix, which gives a very clean background in the low-mass region. Disaccharides with different linkage types give different tandem mass spectral profiles from various cross-ring fragmentation pathways. Disaccharides with the same linkage type but with three different kinds of monosaccharide residues bear the same fragmentation profiles. However, the relative ratios of the fragment ion intensities were found to be distinctly different among the three disaccharide isomers. By employing statistical tools such as LDA to classify the tandem mass spectra, disaccharide isomers with either different linkages or different monosaccharide residues were successfully classified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Throughput Enzyme Kinetics Using Microarrays

We report a microanalytical method to study enzyme kinetics. The technique involves immobilizing horseradish peroxidase on a poly-L-lysine (PLL)- coated glass slide in a microarray format, followed by applying substrate solution onto the enzyme microarray. Enzyme molecules are immobilized on the PLL-coated glass slide through electrostatic interactions, and no further modification of the enzyme or glass slide is needed. In situ detection of the products generated on the enzyme spots is made possible by monitoring the light intensity of each spot using a scientific-grade charged-coupled device (CCD). Reactions of substrate solutions of various types and concentrations can be carried out sequentially on one enzyme microarray. To account for the loss of enzyme from washing in between runs, a standard substrate solution is used for calibration. Substantially reduced amounts of substrate solution are consumed for each reaction on each enzyme spot. The Michaelis constant K{sub m} obtained by using this method is comparable to the result for homogeneous solutions. Absorbance detection allows universal monitoring, and no chemical modification of the substrate is needed. High-throughput studies of native enzyme kinetics for multiple enzymes are therefore possible in a simple, rapid, and low-cost manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗