Design optimization of an additively manufactured prototype recuperator for supercritical CO 2 power cycles

Supercritical CO 2 (sCO 2 ) power cycles are being developed due to their potential for high efficiency and reduced capital cost. It is necessary that these recuperators operate at high pressures and temperatures, up to 30 MPa and 900 K, with effectiveness values > 95% and pressure drops <1% to achieve high cycle efficiencies. Moreover, it is also necessary to have reasonable cost recuperators to control the capital costs of the sCO 2 power cycles. In this study, a Plate Pin-Fin (PPF) heat exchanger has been proposed as an sCO 2 recuperator. This preliminary recuperator design leverages capabilities enabled by additive manufacturing. Although the PPF design has characteristics similar to those of a plate heat exchanger, small diameter and relatively long fins are used to increase surface area, enhance heat transfer, and provide structural support for the partition plates that separate the fluid streams. Existing correlations for heat transfer and pressure drop were adapted for the PPF heat exchanger. These correlations were implemented in a 1D analytical model and used for the optimization of a 5-kW th high temperature recuperator for an indirect sCO 2 cycle by varying the design parameters to minimize the quantity of material required. A 3D conjugate heat transfer numerical simulations were conducted to validate the heat transfer and pressure loss correlations. A steepest descent method was used to minimize heat exchanger mass for a 5-kW prototype recuperator subject to a maximum specified pressure drop. Additionally, the design analysis indicated that an optimum PPF recuperator would be attained for the minimum allowable pin transverse spacing, minimum pin width, minimum pin height and near maximum cell aspect ratio. Moreover, at a low material requirement of 0.216 kg/kW and a pressure drop, which is almost five times lower than the allowable pressure drop design target, the optimized PPF heat exchanger has the high potential to be an alternative to a printed circuit heat exchanger, which is a conservative design basis for the current state-of-the-art sCO 2 recuperators.

42 ENGINEERING↗

Heat Transfer Coefficients of Additively Manufactured Tubes with Internal Pin Fins for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in additively manufactured tubes with internal pin fins at the US DOE’s National Energy Technology Laboratory in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over Reynolds numbers (ReD) ranging from 5 × 10 4 to 2.5 × 10 5 , measured Nu was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow. The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section and were printed at a 30⁰ angle relative to the inner wall (to meet AM constraints). The pin arrangement was helical to promote enhanced heat transfer due to swirl flow. Pin length to diameter aspect ratio was 1.33, 2, and 8, while the pin diameter to tube diameter ratio was 0.188, 0.125, and 0.063. Tests were performed for ReD varying from 6.9 × 10 4 to 2.2 × 10 5 and at conditions equivalent to the low pressure (LP) outlet (8.69 MPa, 361 K) and the high pressure (HP) inlet (20.7 MPa, 350 K) of the low temperature recuperator (LTR) in an indirect sCO 2 cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients. For the best performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.19), the local heat transfer coefficient increased by 136% relative to the Dittus-Boelter correlation at the LTR low pressure outlet and 194% at the LTR high pressure inlet. These correspond to a 282% and a 271% increase in the product of the heat transfer coefficient and surface area (adjusted for fin efficiency) product, respectively. Large pressure drops across the test articles were observed. For Tube Design A, the average friction factor, across the range of ReD considered, was significantly larger than the McAdams correlation at both the LTR LP outlet and the LTR HP inlet. A thermal performance factor was utilized to express the ratio of material required to build a finned heat exchanger relative to a finless heat exchanger with the same heat duty and pumping power. Tube Design A was estimated to decrease the required heat exchanger material by 13%.

Searle, Matthew↗

Advanced Sensors & Controls FWP Overview

Fossil energy power generation is needed now and in the future, but its role is shifting from baseload operation to fulfilling dispatchable power needs in regions of the United States. Novel sensors and controls will help to increase efficiency, minimize emissions, and reduce operating costs of existing power generation technologies under this increased load following role; and help enable next generation power systems with high efficiency and greater operational flexibility.<br>

Buric, Michael↗

Measuring Heat Transfer Coefficients for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in pin-fin patterned pipes at the US DoE’s National Energy Technology Laboratory (NETL) in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (𝑁𝑢) and friction factor. Over Reynolds numbers (Re D ) ranging from 5×104 to 2.5×105 , measured 𝑁𝑢 was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow.

42 ENGINEERING↗

Measurement of Convective Heat Transfer Coefficients With Supercritical CO 2 Using the Wilson-Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in a smooth tube and compares the results with published correlations for validation. The paper also describes the Heat Exchange and Experimental Testing (HEET) rig recently designed and built at the U.S. Department of Energy’s (DoE’s) National Energy Technology Laboratory (NETL) in Morgantown, WV. Here, the Wilson-plot technique used for measuring the heat transfer coefficients is described along with the data reduction process. The Wilson-plot technique was chosen as the basis for the design of NETL’s HEET rig. Advantages of the Wilson-plot technique include the (1) ability to measure high convective heat transfer coefficients accurately, (2) ability to measure average heat transfer coefficient for complicated heat exchange geometries like those produced using additive manufacturing, (3) ability to measure heat transfer coefficients on both sides of a heat exchanger independently, and (4) simplicity of experimental setup. Capabilities of the HEET rig include pressure to 24 MPa (3500 psig), temperature to 538 °C (1000 °F), mass flow rate to 1.5 kg/s (3 lb/s), and Re to 500,000. The rig is designed to operate with pure CO 2 or a mixture of CO 2 and up to 10% N2 by volume to study the impact of gas mixtures typical of direct-fired sCO 2 power cycles on the convective heat transfer and pressure drop. Preliminary tests in the HEET rig were performed with smooth stainless-steel tube and pure CO 2 , and the results were compared with published correlations for Nusselt number (Nu) and friction factor. Over a Reynolds number (Re) range from 58,000 to 228,000, measured Nu was compared to predictions using the Dittus and Boelter equation (Kreith and Bohn, 1993, “Principles of Heat Transfer, West Publishing Company”) within 5% and measured friction factors were compared to predictions using the McAdams correlation (“McAdams, 1954, “Heat Transmission,” 3rd ed., McGraw Hill, New York)” for smooth tube to be within 5%.

42 ENGINEERING↗