Yoder, Timothy A.

Publications and source records attributed to Yoder, Timothy A..

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A General Purpose Real-Time Optimization Strategy Applied to Minimizing Simultaneous Heating and Cooling in Buildings

Supervisory control strategies in heating, ventilating, and air-conditioning (HVAC) systems hold the potential for significant energy savings but they are difficult to set up and often depend on unreliable sensor measurements. In this paper, we propose a sensor-free approach to minimizing the energy penalties due to simultaneous heating and cooling in variable-air-volume (VAV) systems with reheat. A general-purpose real-time optimizer is described that is easy to set-up and integrate with existing control logic. A cost function is derived that quantifies the simultaneous heating and cooling penalty that does not require any sensor measurements. The optimizer then minimizes this cost function by automatically adjusting the supply temperature setpoint in the air-handling unit. The paper describes the approach and shows results from application from field trials on a 27-zone building.

Salsbury, Timothy↗

Building ControlScore: Research Laboratory Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore tool which captures operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Redefining Net-Zero Water for Resilient Aquifers

Groundwater has long been a critical source of potable water, supplying one-third of all global water withdrawals and providing strategic reserves in times of drought (Konikow, 2012; Famiglietti, 2014). The risk in relying on groundwater is that it is often pumped at rates far greater than it can be naturally replenished. With increasing population and a changing climate, the depletion of potable water supplies has become an ever-growing concern (Srinivasan et al., 2012). Recently, the concept of “resilience” has been applied to groundwater, leaving many questions to be explored in terms of what resilience should mean for aquifers (Foster and MacDonald, 2014; Grönwall and Oduro-Kwarteng, 2017). The term is commonly used to indicate resilience to impacts of climate change specifically, but here we consider resilience in the context of more general water insecurity. Relatedly, the concept of “sustainable yield” has emerged in an attempt to determine a metric that can ensure the long-term resilience of groundwater systems, but the definition is fraught with inherent uncertainties and its quantification poses challenges (Rudestam and Langridge, 2014; Grönwall and Oduro-Kwarteng, 2017). At the heart of these concepts is a focus on sustainable management of aquifers. A sustainable approach to managing groundwater resources usually involves balancing long-term abstraction with the long-term recharge taking into account the needs for environmental flows and implementing drought-preparedness measures (Robins et al. 2006; Foster and MacDonald, 2014). At a high level, a sustainable balance of groundwater abstraction versus aquifer recharge may be considered “Net Zero” (NZ) or “Net Positive” (NP) in cases where recharge is equal to or in excess of abstraction, respectively. However, NZ/NP water management programs that address these concerns have varied definitions of compliance, which include considerations for the application at hand (ILFI, 2020; USGBC, 2020). Locations with high risk of low or poor water supply may be particularly interested in pursuing NZ/NP water. The AQUEDUCT Water Risk Atlas (World Resources Institute, 2019) indicates long-term availability, providing risk levels for quantity and quality of water at specific locations across the globe, for existing and predicted future conditions. This paper follows the U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) NZ water definition adopted by the U.S. Army for use at their installations, including Army Reserve Centers (ARCs). This definition also relates to the U.S. Army’s current focus on water resilience, which includes short-term and long-term availability of water resources.

net zero water, HUC12, Saipan, American Samoa, Mau↗