Search NASA⌕ Search

Engineering topics

Yokosuk, Michael O.

Publications and source records attributed to Yokosuk, Michael O..

Method to derive the infrared complex refractive indices n(λ) and k(λ) for organic solids from KBr pellet absorption measurements

Obtaining the complex refractive index vectors $n($$\tilde{v})$ and $k($$\tilde{v})$ allows calculation of the (infrared) reflectance spectrum that is obtained from a solid in any of its many morphological forms. Here, we report an adaptation to the KBr pellet technique using two gravimetric dilutions to derive quantitative $n($$\tilde{v})$/$k($$\tilde{v})$ for dozens of powders with greater repeatability. The optical constants of bisphenol A and sucrose are compared to those derived by other methods, particularly for powdered materials. The variability of the $k$ values for bisphenol A was examined by 10 individual measurements, showing an average coefficient of variation for $k$ peak heights of 5.6%. Though no established standards exist, the pellet-derived $k$ peak values of bisphenol A differ by 11% and 31% from their single-angle- and ellipsometry-derived values, respectively. These values provide an initial estimate of the precision and accuracy of complex refractive indices that can be derived using this method. Limitations and advantages of the method are discussed, the salient advantage being a more rapid method to derive $n$/$k$ for those species that do not readily form crystals or specular pellets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for Determining the Infrared Complex Refractive Indices n (λ) and k (λ) from Organic Solid Powders: Comparison of a Sucrose Single Crystal and a Pressed Pellet

There exists a need to measure optical constants n and k for many materials, especially organic solids in the infrared spectral region, but at present, there are only two established methods for making such measurements: single-angle (SA) reflectance and infrared spectroscopic ellipsometry (IRSE). The former derives the n/k vectors via measurement of the change in the amplitude of light reflected from the sample and then uses the Kramers–Kronig transform, while the latter measures the change in polarization of the reflected light from the sample to derive n/k. Here we make a direct comparison between the n/k vectors derived from SA measurements of a sucrose single crystal and the n/k values obtained after the crystal had been crushed, ground to powder, and pressed into a pellet form. The pellet was measured not only by SA but also via the IRSE method, and we found that pressing specular-quality pellets was critical, especially for the SA data. The n/k values of this typical organic molecule all agree to within 0.04 root-mean-square error, confirming that a pressed pellet can be used instead of a crystal to derive the intrinsic n/k vectors. In conclusion, this result is important for the many organic materials that, unlike sugar, do not have centimeter-sized crystals readily available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining Infrared Optical Constants for Dolomite using Single Angle Reflectance and Spectroscopic Ellipsometry

The optical constants, namely the real (n) and imaginary (k) parts of the complex refractive index, are of particular interest to generate the infrared (IR) spectra of liquid and solid materials in different morphologies. To obtain n/k, however, most materials are typically not found in the monolithic forms necessary to easily measure n/k, and thus require the use of other methods such as pressing powders to form planar, specularly-reflective pellets. In this work dolomite crystals are measured using fixed-angle IR reflectance spectroscopy in both 1) a monolithic form with the crystal fixed in epoxy and polished, but data are also recorded from 2) pressed-pellet forms of powders of the same mineral using the same spectroscopic protocols. First results for the two methods are compared. It was found that the measured reflectance can vary by as much as a factor of two between the dolomite crystals and the pressed powder forms. For the two-sample preparation approaches the preliminary spectra are compared and the implications and limitations of each method for determining the optical constants of given materials are discussed. Comparison to literature data suggest that polarization effects likely account for the differing amplitude results for reflectance (and hence the k -vectors): Dolomite is known to be biaxial with significantly differing ordinary and extraordinary rays; the pressed pellet method measures an ensemble of microcrystals in randomly oriented positions, whereas the single crystal maintains just one orientation relative to the optical axis.

ellipsometry, dolomite, complex refractive index, ↗

Using spectroscopic ellipsometry and single-angle reflectance to derive accurate optical constants for chemical forms of aspartame

Variable angle spectroscopic ellipsometry and single-angle infrared reflectance methods have been used to derive the complex optical constants n and k in the mid-infrared spectral region for aspartame. Aspartame exists in four unique forms – three of which incorporate water into the lattice, as well as the anhydrate form. The different forms can induce splitting or slight wavenumber shifts in the spectral features. Pressed pellets of neat powder were prepared and measured using both methods to derive the optical constants. Different n and k values were obtained depending on the percentage of the forms of aspartame, which was determined using powder X-ray diffraction (XRD) analysis.

optical constants, refractive index, extinction co↗

Combining Spectroscopic Ellipsometry with Transmission Spectroscopy to Derive Accurate Optical Constants for Organic Materials

A method for deriving the optical constants of organic powdered materials in the mid-infrared spectral range is introduced using variable angle spectroscopic ellipsometry and transmission spectroscopy. The approach uses pressed pellets of the powder and is applied to organic solids, which have both strong and weak infrared absorption features. Many powders have significant voids and do not press into smooth, homogenous pellets. To account for pellet non-idealities and to accurately measure both n and k, three different forms of pellets were pressed and measured: A pure analyte pellet, a mixed analyte/KBr pellet with a large analyte percentage, and a KBr transmission pellet with only a small analyte percentage. Using all three pellets in a multi-sample analysis involving both ellipsometric and transmission data, the complex refractive index (n/k) values can be derived for many organic compounds. This method is illustrated to calculate the optical constants for anhydrous lactose from 6000-400 cm-1. The transmission measurements improve the spectral fitting of weak absorption features, and the multi-sample analysis enables a better determination of the significant void space that is present in the pure pellet, leading to lower values for both n and k if not properly accounted for in the multi-oscillator model used to fit the ellipsometric data.

Optical constants, refractive index, extinction co↗

Measuring accurate optical constants of uranium minerals for use in optical modeling of infrared spectra

Knowledge of the bulk optical constants n and k of solids or liquids allows researchers to accurately predict the absorption, reflection, and scattering properties of materials for different physical forms. Indeed, chemically complex materials such as minerals can have an almost limitless variety of morphologies, particle sizes, shapes, and compositions, but the optical properties of such species can be predicted if the optical constants are known. For species such as minerals, however, there can be additional challenges due to e.g. hydration or dehydration during the course of the optical constants measurement. Here, we describe the protocols to obtain the bulk optical constants n and k of uranium-bearing minerals and ores such as uraninite or autunite. If quality n and k data are at hand, the (infrared) reflectance spectra can be predicted for different particle sizes and morphologies and the modeling results for various scenarios can be derived.

infrared (IR) spectroscopy, optical constants, ura↗

Combining Spectroscopic Techniques to Determine the Optical Constants of Powdered Lactose

A method for deriving the optical constants (n/k) of organic powdered materials using pressed pellets in the mid-infrared spectral range is introduced that combines variable angle spectroscopic ellipsometry and transmission spectroscopy. The approach is applied to lactose, in which three different forms of pellets were pressed and measured: A pure lactose pellet and a mixed lactose/KBr pellet with a large analyte percentage were used for ellipsometric measurements, and a KBr transmission pellet with only a small analyte percentage were used for transmission measurements. The transmission data provide an initial set of oscillators and improve the spectral fitting of weak absorption features (k<0.01). Ellipsometric data for the pure and mixed pellets are then fit simultaneously to derive the final n/k values for lactose from 6000-400 cm-1. An alternative method just using the ellipsometric data from the mixed pellet and the transmission data is also presented and shows good agreement with the multi-sample analysis, providing a simpler method for powders that do not press easily into pure pellets. Finally, the derived optical constants are used to model the reflectance data, demonstrating a good match with the measured reflectance spectra if non-idealities are included.

Yokosuk, Michael O.↗

Preliminary parameter studies to form pellets of hard materials for optical constants derived via single-angle reflectance spectroscopy

Infrared reflectance spectra can be influenced by many factors: the substrate and the thickness of the layer for liquids and the surface micromorphology, the form (powder, crystal) and the particle size for solids. All these parameters can play a role in the appearance of the measured spectrum. To avoid collecting multitudes of spectra to cover all such scenarios, the optical constants n and k, which are intrinsic properties of a material, can instead be used to model the reflectance spectrum. For solids, two techniques are often used to derive optical constants: ellipsometry and single-angle reflectance spectroscopy. For both methods, best results are usually obtained from single crystals. We have recently demonstrated for ammonium sulfate (a relatively soft material) that by optimizing certain conditions, high quality pellets with specularly reflective surfaces can be used in lieu of crystals. This was confirmed by the excellent agreement between the optical constants derived by these two methods. This work focuses on the possible extension of these methods to harder materials, starting with sodium sulfate. The first goal is to see if high quality pellet surfaces can be obtained as for ammonium sulfate. The reflectance values and the associated optical constants can also be obtained.

Diaz, Emmanuela↗

Improved Infrared Optical Constants from Pressed Pellets: II. Ellipsometric n and k Values for Ammonium Sulfate with Variability Analysis

Infrared spectral imaging is facilitated via the comparison of spectra recorded in situ to a databank of actual or synthetic infrared reflectance spectra. It has recently been shown that reference spectra corresponding to the many different morphological forms of the same chemical can be generated synthetically using the imaginary, k, and real, n, components of the complex refractive index, n~ = n + ik. One method to obtain the n and k vectors is infrared ellipsometry, which measures the changes in amplitude, tan ?, and phase, ?, of polarized light reflected from the sample both as a function of wavenumber and angle of incidence. The method requires specularly reflected light so best results are usually obtained with polished planar samples of large surface area. Due to the difficulties of obtaining such samples, however, we investigate the possibility of pressing powders of neat materials and obtaining the corresponding optical constants from the pellets. In this paper, variability in the sample pellet and preparation method is investigated, as is variability in the fitting procedure for the derived optical constants. The n/k vectors are derived from the measured ellipsometric parameters, tan ? and ?, as they are fit by an oscillator model which yield n(?) and k(?) vectors as a function of wavenumber, ?. Construction of the oscillator model is not automatic and depends on significant input from the analyst as well as the sample’s physical characteristics. For the pellet pressing, the experimental variability was found to be minimized for size-selected powdered samples as gauged by the minimal variance in ? and ? for three different pellets; similarly, the analytical precision for multiple measurements of the same pellet was also quite good, suggesting that a pressed pellet is a viable sample preparation method. The greatest variability came in the analytic fitting procedure with differences up to 20% arising from four different fits to the same data set. The final ellipsometric n/k data are compared to literature values obtained from crystalline (NH4)2SO4 samples as well as single-angle reflectance measurements that also used pressed pellets. Comparison with the previous literature values shows generally good agreement although higher k-values are observed for the independent sets of data derived from pressed pellets. These data are suggested as an improved set of optical constants for (NH4)2SO4.

optical constants, ellipsometry, ammonium sulfate,↗

Nonreciprocal directional dichroism of a chiral magnet in the visible range

Nonreciprocal directional dichroism is an unusual light–matter interaction that gives rise to diode-like behavior in low-symmetry materials. The chiral varieties are particularly scarce due to the requirements for strong spin–orbit coupling, broken time-reversal symmetry, and a chiral axis. Here we bring together magneto-optical spectroscopy and first-principles calculations to reveal high-energy, broadband nonreciprocal directional dichroism in Ni 3 TeO 6 with special focus on behavior in the metamagnetic phase above 52 T. In addition to demonstrating this effect in the magnetochiral configuration, we explore the transverse magnetochiral orientation in which applied field and light propagation are orthogonal to the chiral axis and, by so doing, uncover an additional configuration with a unique nonreciprocal response in the visible part of the spectrum. In a significant conceptual advance, we use first-principles methods to analyze how the Ni 2+ d-to-d on-site excitations develop magneto-electric character and present a microscopic model that unlocks the door to theory-driven discovery of chiral magnets with nonreciprocal properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗