Search NASA⌕ Search

Engineering topics

Yoon, W.

Publications and source records attributed to Yoon, W..

Study of Dissipative Losses in AC-Biased Mo/Au Bilayer Transition-Edge Sensors

We are developing kilo-pixel arrays of transition-edge sensors (TESs) for the X-ray Integral Field Unit on ESA's (European Space Agency's) Athena observatory. Previous measurements of AC-biased Mo/Au TESs have highlighted a frequency-dependent loss mechanism that results in broader transitions and worse spectral performance compared to the same devices measured under DC (Direct Current) bias. In order to better understand the nature of this loss, we are now studying TES pixels in different geometric configurations. We present measurements on devices of different sizes and with different metal features used for noise mitigation and X-ray absorption. Our results show how the loss mechanism is strongly dependent upon the amount of metal in close proximity to the sensor and can be attributed to induced eddy current coupling to these features. We present a finite element model that successfully reproduces the magnitude and geometry dependence of the losses. Using this model, we present mitigation strategies that should reduce the losses to an acceptable level.

Sakai, K.↗

Magnetic Calorimeter Arrays with High Sensor Inductance and Dense Wiring

We describe prototype arrays of magnetically coupled microcalorimeters fabricated with an approach scalable to very large format arrays. The superconducting interconnections and sensor coils have sufficiently low inductance in the wiring and sufficiently high inductance in the coils in each pixel, to enable arrays containing greater than 4000 sensors and 100,000 X-ray absorbers to be used in future astrophysics missions such as Lynx. We have used projection lithography to create submicron patterns (e.g., 400-nanometer-lines and spaces) in our niobium sensor coils and wiring, integrated with gold-erbium sensor films and gold X-ray absorbers. Our prototype devices will explore the device physics of metallic magnetic calorimeters as feature sizes are reduced to nanoscale.

Magnetism↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

Effects of Normal Metal Features on Superconducting Transition-Edge Sensors

In transition-edge sensors (TESs), the addition of normal metal stripes on top of the superconducting bilayer, perpendicular to the current direction, is known to globally alter the sensitivity of the resistance R to changes in temperature T and current I. Here, we describe measurements of the dependence of the TES current on magnetic field B, bath temperature and voltage bias in devices with various numbers of stripes. We show that the normal metal features have a profound effect on the appearance of localized regions of very large (T/R) dR/dT. We associate this with changes in the current distribution and corresponding changes in the oscillatory pattern of I (B). 140 μm TESs with no stripes are found to have a relatively smooth resistive transition and sufficiently low noise that the measured energy resolution is 1.6 eV for X-rays of 1.5 keV. The predicted energy resolution at 6 keV is better than 2 eV, once the heat capacity is optimized for these higher energies..

Wakeham, N. A.↗

The Effects of Normal Metal Stripes on TES Performance

Exploring the effects of size and geometry of normal metal features on the transition shapes and performance of transition-edge sensor microcalorimeters. The spectral resolution of transition-edge sensor (TES) microcalorimeters is very sensitive to the specific dependencies of the resistance R in the superconducting transition on the current I, magnetic field B, and temperature T. In particular, it has been shown that transitions that are very steep in (R,T) space lead to a significant noise term, in excess of conventional expectations. This so-called unexplained noise is known to be reduced by the addition of normal metal stripes across the TES perpendicular to the direction of current flow. These normal metal stripes have been shown to drastically alter the oscillatory patterns seen in measurements of the critical current as a function of magnetic field. However, there are many remaining questions about the exact impact of the stripes on current distributions within the TES, the Fraunhofer pattern and, therefore, the shape of the R(I, B, T) surface. Through measurements of the resistance under DC bias of TES devices of various sizes, with different stripe patterns and dimensions, we will discuss how these stripes can affect the R(I, B, T) surface. In addition, using measurements and analysis of the noise spectra of various devices we will present how these changes to the stripe pattern may affect the performance of the TES. In particular, we will discuss strategies to reduce the presence of localized discontinuities in the derivative of R, associated with increased noise, while maintaining the globally low levels of unexplained noise currently achieved with conventional metal stripe patterns. Implementing these strategies is a path towards producing large arrays with highly uniform transitions and high spectral resolution. These large uniform arrays will be required for future x-ray astronomy applications, such as the X-IFU on ATHENA.

TES↗

Transition-Edge Sensor Pixel Parameter Design of the Microcalorimeter Array for the X-Ray Integral Field Unit on Athena

The focal plane of the X-ray integral field unit (X-IFU) for ESA's Athena X-ray observatory will consist of approximately 4000 transition edge sensor (TES) x-ray microcalorimeters optimized for the energy range of 0.2 to 12 kiloelectronvolts. The instrument will provide unprecedented spectral resolution of approximately 2.5 electronvolts at energies of up to 7 kiloelectronvolts and will accommodate photon fluxes of 1 milliCrab (90 counts per second) for point source observations. The baseline configuration is a uniform large pixel array (LPA) of 4.28 arcseconds pixels that is read out using frequency domain multiplexing (FDM). However, an alternative configuration under study incorporates an 18 by × 18 small pixel array (SPA) of 2 arcseconds pixels in the central approximately 36 arcseconds region. This hybrid array configuration could be designed to accommodate higher fluxes of up to 10 milliCrabs (900 counts per second) or alternately for improved spectral performance (less than 1.5 electronvolts) at low count-rates. In this paper we report on the TES pixel designs that are being optimized to meet these proposed LPA and SPA configurations. In particular we describe details of how important TES parameters are chosen to meet the specific mission criteria such as energy resolution, count-rate and quantum efficiency, and highlight performance trade-offs between designs. The basis of the pixel parameter selection is discussed in the context of existing TES arrays that are being developed for solar and x-ray astronomy applications. We describe the latest results on DC biased diagnostic arrays as well as large format kilo-pixel arrays and discuss the technical challenges associated with integrating different array types on to a single detector die.

Smith, S. J.↗