Search NASA⌕ Search

Engineering topics

Youchison, Dennis L.

Publications and source records attributed to Youchison, Dennis L..

At least 19 records

Qualification and Commissioning of Helium Flow Loop Experiment for Blanket Design Measurements

Sufficient cooling of plasma-facing materials remains an outstanding challenge in the design of fusion reactor blankets in commercial power demonstration plants. Due to its chemical inertness and low neutron interaction cross section, pressurized helium is a candidate coolant fluid for such systems; however, helium has a small thermal mass compared to liquid coolants, potentially reducing heat removal performance. To address this need, a number of heat transfer enhancements have been proposed to improve the cooling efficiency of such components, thereby decreasing pumping power needs and improving overall plant efficiency. Toward this end, a helium flow loop experiment (HFLE) has been designed and commissioned to test advanced passive heat transfer enhancements in unit-cell test sections, providing necessary data for model validation and subsequent system design. The HFLE is designed to provide flow of pressurized (up to 4 MPa) helium at flow rates up to 80 g/s, enabling heat transfer and pressure drop measurements in test pieces at Reynolds numbers in excess of 180 000. To explore the effects of novel and complex heat transfer enhancements, test sections are produced via additive manufacturing, providing geometries not typically obtainable by conventional machining. Here in this work, we present results from HFLE commissioning and the initial thermal-hydraulic tests of an additively manufactured rifled-rib test section. Results are compared to smooth pipe correlations, and plans are described for future HFLE measurements. These preliminary experiments indicate the utility of the HFLE for heat transfer enhancement testing and simulation validation activities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Analysis of Liquid Metal MHD Flow and Heat Transfer for Open-Surface Li Divertor in FNSF

Within the ongoing U.S.-based program on the development of liquid metal plasma-facing components, numerical simulations and analyses are performed to address the feasibility of the open-surface Li divertor. In the previous scoping studies (Smolentsev, 2021), heat-removal capabilities of the divertor were assessed using a simplified flow model for a slug-type velocity profile and constant flow thickness. Here, new analyses take into account forces acting on the flowing Li layer. Three reduced-order mathematical models are applied under the conditions of the U.S. Fusion Nuclear Science Facility (FNSF) to access magnetohydrodynamic (MHD) flow development effects, velocity distribution, and surface waves: 1) fully developed MHD flow; 2) quasi-2-D developing MHD flow; and 3) multiphase MHD flow. The obtained results for MHD flows and the surface heat flux computed with the plasma code scrape-off layer plasma simulation for ITER (SOLPS-ITER) are then used as input data to compute the temperature distribution in the divertor by solving the convection–diffusion energy equation.

Smolentsev, Sergey↗

Circumferential flow foam heat exchanger

A heat exchanger is disclosed that includes a cold heat exchange zone including a foam material having an annular geometry and having fluid distribution and collection slots configured to distribute a cooling fluid circumferentially through the foam material.

Youchison, Dennis L.↗

Design and Analysis of High Heat Flux Plasma-Facing Components for NSTX Upgrade

The National Spherical Tokamak Experiment (NSTX) upgrade (NSTX-U) requirements lead to enhanced heat loads on plasma-facing components (PFCs) especially in the divertor regions, where normal heat flux density can reach up to 8 MW/m 2 . For these high heat flux (HHF) regions, the PFCs were redesigned, to use castellations which relieved the thermal stresses associated with high incident heat flux. Another design feature of HHF PFCs is the absence of front face mounting holes which create localized areas of high temperature and thermal stress concentrations. Optimized shaping of the front face of the HHF PFCs eliminates regions where the front face is perpendicular to the heat flux direction during normal helicity operation and spreads the heat load. A unique mechanism was designed to connect PFC tiles to the NSTX-U center stack casing using locking features accessible from the low heat flux regions. Isotropic graphite was selected as the HHF PFC tile material. Initial tile design parameters were accessed using analytical expressions for pulsed heat flux loading. A working prototype of the locking mechanism was created during the initial stages of the design to prove the concept performance. This article presents an overview of the divertor HHF PFC design and the results of the thermal and structural analyses performed using ANSYS software. The results of the analyses cover normal operating conditions and disruptions which impose electromagnetic (EM) loads from eddy and halo currents. The 3-D, transient, nonlinear analyses took into account the temperature-dependent properties of the materials, friction interfaces between the parts, and variable electric properties of the parts and interfaces. The results confirm that the HHF PFC tiles remain within the allowable limits for the loads defined by the NSTX-U Recovery Project. In addition, tolerance stack up analyses were performed to ensure tile performance in the worst possible assembly configuration. Finally, the design process was completed successfully, and the NSTX HHF PFC tiles are currently in the production phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Performance of Tungsten-Coated Graphitic Foam for Plasma-Facing Components

High-density graphitic foam is an ideal low-Z plasma-facing material for deuterium-deuterium plasma experiments where tritium codeposition is not an issue. However, like all carbon, graphitic foam suffers from a precipitous drop in thermal conductivity at high temperatures, >600°C. To mitigate these problems, functionally graded layers of tungsten can be deposited to a thickness of 2 to 4 mm onto the plasma side of the foam using chemical vapor deposition. The graphitic foam then acts as a high-conductivity heat sink at temperatures below 600°C for the thin high-Z armor coating. The overall component weighs 18 times less than a comparable volume of tungsten and lacks the coefficient of thermal expansion joining issues between the CuCrZr tubing and the tungsten. This paper discusses the coating development and characterization and presents the results of recent plasma exposures in W7-X. It also reports on computational fluid dynamics heat transfer modeling and preparations for high heat flux testing of mock-ups. This hybrid plasma-facing component (PFC) consisting of innovative engineered materials may be a cost-effective, actively cooled solution for the divertors and other PFCs in long-pulse machines like W7-X and WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced manufacturing—A transformative enabling capability for fusion

Additive Manufacturing (AM) can create novel and complex engineered material structures. Features such as controlled porosity, micro-fibers and/or nano-particles, transitions in materials and integral robust coatings can be important in developing solutions for fusion subcomponents. A realistic understanding of this capability would be particularly valuable in identifying development paths. Major concerns for using AM processes with lasers or electron beams that melt powder to make refractory parts are the power required and residual stresses arising in fabrication. A related issue is the required combination of lasers or e-beams to continue heating of deposited material (to reduce stresses) and to deposit new material at a reasonable built rate while providing adequate surface finish and resolution for meso-scale features. Some Direct Write processes that can make suitable preforms and be cured to an acceptable density may offer another approach for PFCs.

Additive Manufacturing, fusion energy, Fusion Mate↗

Integrated plasma facing component calorimetry for measurement of shot integrated deposited energy in the NSTX-U

Here, the upgrade to the National Spherical Torus eXperiment (NSTX-U) increases the injected neutral beam power up to 12 MW and the plasma current up to I p = 2 MA for plasma durations up to 5 s. The graphite plasma facing components have been re-designed to handle greater heat and energy fluxes than were seen in NSTX using a castellated design. We present the experimental testing and validation of a castellated graphite target, similar to the prototype tile design, instrumented with thermocouples at various depths in the castellation. During testing, incident heat flux is provided by a programmed electron beam system and surface temperatures are measured via infrared thermography directly viewing the target surface. It was found that the thermocouple response scaled linearly with the measured surface temperature rise regardless of thermocouple depth in the castellation. A sensitivity of 14.3 °C/kJ of deposited energy was found when treating individual castellations as a semi-infinite solid.

47 OTHER INSTRUMENTATION↗

ITER ECH Switch Design and Analysis

The electron cyclotron heating system (ECH) on ITER uses 24 evacuated microwave transmission lines carrying up to 1.4 MW of power each at 170 GHz to provide resonance heating of electrons in the ITER plasma and to enable plasma current drive. A critically important component in this system is the microwave switch that allows the microwaves to be directed from the gyrotrons to either dummy loads or between launchers in the upper and equatorial ports of the ITER tokamak while maintaining the vacuum integrity of the transmission lines. A moveable, water-cooled CuCrZr mirror is used to redirect the microwave transmission between two orthogonal waveguides. In this paper, we describe the optimized design of the mirror cooling passages produced by computational fluid dynamics analysis using ANSYS CFX with k-ε and k-ω shear stress transport turbulence models, and verify that the design parameters for mass flow rate, inlet temperature and pressure are adequate for good thermomechanical performance. Non-uniform heating of the mirror face from the incident microwaves induces deflections that should be less than 25 microns to meet the integrated transmission line efficiency specification. In the current 1.4 MW switch design, 0.03 kg/s of 36°C water at 10 bar inlet pressure can remove the 2660 W of ohmic heating in the mirror produced by the elliptical polarization power and maintain the surface temperature below 150°C. The water delta-T is 21°C with a 0.5 bar pressure drop in the mirror. Finally, the maximum predicted displacement in the center of the mirror face is less than 25 μm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow instabilities in non-uniformly heated helium jet arrays used for divertor PFCs

In this study, due to a lack of prototypical experimental data, little is known about the off-normal behavior of recently proposed divertor jet cooling concepts. This article describes a computational fluid dynamics (CFD) study on two jet array designs to investigate their susceptibility to parallel flow instabilities induced by non-uniform heating and large increases in the helium outlet temperature. The study compared a single 25-jet helium-cooled modular divertor (HEMJ) thimble and a micro-jet array with 116 jets. Both have pure tungsten armor and a total mass flow rate of 10 g/s at a 600 °C inlet temperature. We investigated flow perturbations caused by a 30 MW/m 2 off-normal heat flux applied over a 25 mm 2 area in addition to the nominal 5 MW/m 2 applied over a 75 mm 2 portion of the face. The micro-jet array exhibited lower temperatures and a more uniform surface temperature distribution than the HEMJ thimble. We also investigated the response of a manifolded nine-finger HEMJ assembly using the nominal heat flux and a 274 mm 2 heated area. For the 30 MW/m2 case, the micro-jet array absorbed 750 W in the helium with a maximum armor surface temperature of 1280 °C and a fluid/solid interface temperature of 801 °C. The HEMJ absorbed 750 W with a maximum armor surface temperature of 1411 °C and a fluid/solid interface temperature of 844 °C. For comparison, both the single HEMJ finger and the micro-jet array used 5-mm-thick tungsten armor. The ratio of maximum to average temperature and variations in the local heat transfer coefficient were lower for the micro-jet array compared to the HEMJ device. Although high heat flux testing is required to validate the results obtained in these simulations, the results provide important guidance in jet design and manifolding to increase heat removal while providing more even temperature distribution and minimizing non-uniformity in the gas flow and thermal stresses at the armor joint.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗