Search NASA⌕ Search

Engineering topics

Young, John

Publications and source records attributed to Young, John.

Discerning molecular-level CO 2 adsorption behavior in amine-modified sorbents within a controlled CO 2 /H 2 O environment towards direct air capture

Sorbents designed for direct air capture (DAC) play a crucial role in the pursuit of achieving net-zero carbon dioxide emissions. This study elucidates CO 2 adsorption from dilute, humidified CO 2 streams onto an amine-modified benchmark DAC adsorbent via solid-state NMR spectroscopy. Various NMR techniques, including 1D 1 H MAS, 13 C MAS, 2D 1 H– 13 C HETCOR NMR, and 1 H R 2 and R 1ρ relaxometry reveal the impact of CO 2 partial pressure and H 2 O on CO 2 adsorption behavior. Here we find that CO 2 concentration governs the stepwise formation of ammonium carbamate, carbamic acid, and physisorbed CO 2 , where relative humidity (RH) at a desired low (<400 ppm) CO 2 loading affects total CO 2 uptake. The relaxation studies reveal the cooperative or competitive nature of H 2 O–CO 2 sorption in CO 2 -dilute humid gas, and in particular polymer swelling upon humidification. From those results, we demonstrate that the observed absorption capacity enhancement by humidity is caused by pore opening due to sorbent swelling, and not by bicarbonate formation. This NMR-discerned speciation provides insights into sorption behavior at different RHs in dilute CO 2 gas streams, simulating real-world atmospheric conditions, and governs the design of efficient and adaptable material-process combinations for solid sorbent DAC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The cost of direct air capture and storage can be reduced via strategic deployment but is unlikely to fall below stated cost targets

Carbon dioxide removal (CDR) is necessary to minimize the impact of climate change by tackling hard-toabate sectors and historical emissions. Direct air capture and storage (DACS) is an important CDR technology, but it remains unclear when and how DACS can be economically viable. Here, we use a bottom-up engineering-economic model together with top-down technological learning projections to calculate plant-level cost trajectories for four DACS technologies. Our analysis demonstrates that the costs of these technologies can plateau by 2050 at around $\$$100-600 t-CO 2 -1 mainly via capital cost reduction through aggressive deployment, but still exceed the optimistic targets defined by countries such as the US (i.e., $\$$100 t-CO 2 -1 ). A further analysis of existing policy mechanisms indicates that strong, project-catered policy support will be required to create market opportunities, accelerate DACS scale-up and lower the costs further. Our work suggests that strategic DACS deployment and operation must be coupled with strong policies to minimise the cost of DACS and maximise the opportunity to make a planet-scale climate impact.

54 ENVIRONMENTAL SCIENCES↗

Process-informed adsorbent design guidelines for direct air capture

Direct air capture using solid adsorbents is a proven technology critical to reducing our net greenhouse gas emissions to zero and beyond. Currently, academic research into the technology mainly focuses on the development of new adsorbents. However, there is a discord between the adsorbent design and process performance. Many materials scientists focus on maximising metrics such as the CO 2 capacity of their adsorbent. Here, we combine detailed process modelling, machine learning, and extensive global sensitivity analysis, which entails varying all of the model parameters together, on a direct air capture process to show that the dry CO 2 adsorption capacity does not influence process performance for an amine-functionalised adsorbent operating in a temperature vacuum swing adsorption (TVSA) process, while it is important in a steam-assisted TVSA (S-TVSA) process. In fact, adsorption kinetics, density, and thermal conductivity are all critical attributes to obtaining a low energy penalty and reduced costs. The analysis also highlights the importance of heat transfer, directing process engineers to (alternative) adsorber designs that maximise this. By an in-depth evaluation of how process performance indicators are affected by materials properties and process operating parameters, this work provides guidance to both material scientists and process engineers towards the design of a “unicorn adsorbent” and intensified DAC processes. This will improve the performance of solid adsorbent direct air capture and help drive down the costs of this vital technology to avert the worst impacts of climate change.

42 ENGINEERING↗

Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automation and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An immersed boundary method for fluid–structure interaction with compressible multiphase flows

This paper presents a two-dimensional immersed boundary method for fluid–structure interaction with compressible multiphase flows involving large structure deformations. This method involves three important parts: flow solver, structure solver and fluid–structure interaction coupling. In the flow solver, the compressible multiphase Navier–Stokes equations for ideal gases are solved by a finite difference method based on a staggered Cartesian mesh, where a fifth-order accuracy Weighted Essentially Non-Oscillation (WENO) scheme is used to handle spatial discretization of the convective term, a fourth-order central difference scheme is employed to discretize the viscous term, the third-order TVD Runge–Kutta scheme is used to discretize the temporal term, and the level-set method is adopted to capture the multi-material interface. In this work, the structure considered is a geometrically non-linear beam which is solved by using a finite element method based on the absolute nodal coordinate formulation (ANCF). The fluid dynamics and the structure motion are coupled in a partitioned iterative manner with a feedback penalty immersed boundary method where the flow dynamics is defined on a fixed Lagrangian grid and the structure dynamics is described on a global coordinate. We perform several validation cases (including fluid over a cylinder, structure dynamics, flow induced vibration of a flexible plate, deformation of a flexible panel induced by shock waves in a shock tube, an inclined flexible plate in a hypersonic flow, and shock-induced collapse of a cylindrical helium cavity in the air), and compare the results with experimental and other numerical data. The present results agree well with the published data and the current experiment. Finally, we further demonstrate the versatility of the present method by applying it to a flexible plate interacting with multiphase flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation into Cause of Cs-137 Source Leakage

During the morning of September 28, 2011 a pig containing a sealed source used for source checking detectors, tipped over in the Collider-Accelerator Department (C-AD) Radiological Control van. Several hours later, the Radiological Control Technician (RCT) detected low levels of radioactivity on his shoes, and the floor mat of the vehicle, as well as a personal vehicle owned by a facilities and operations (F&O) tradesman who took the RCT to lunch at the BNL cafeteria. Areas that were checked for contamination included offices, work station, RCTs themselves, the tradesman and the cafeteria. Several areas of contamination were detected in the parking lot, the floor of the source storage building, and also detectors where the source had been used that day. All areas were secured or decontaminated. The initial results reported in the afternoon of 9/28 were preliminary, and the final determination on its report ability was deferred until more information could be obtained after additional smear results were performed.

07 ISOTOPE AND RADIATION SOURCES↗

Health maintenance facility: Dental equipment requirements

The objectives were to test the effectiveness of the Health Maintenance Facility (HMF) dental suction/particle containment system, which controls fluids and debris generated during simulated dental treatment, in microgravity; to test the effectiveness of fiber optic intraoral lighting systems in microgravity, while simulating dental treatment; and to evaluate the operation and function of off-the-shelf dental handheld instruments, namely a portable dental hand drill and temporary filling material, in microgravity. A description of test procedures, including test set-up, flight equipment, and the data acquisition system, is given.

Young, John↗

Dental equipment test during zero-gravity flight

The overall objectives of this program were to establish performance criteria and develop prototype equipment for use in the Health Maintenance Facility (HMF) in meeting the needs of dental emergencies during space missions. The primary efforts during this flight test were to test patient-operator relationships, patent (manikin) restraint and positioning, task lighting systems, use and operation of dental rotary instruments, suction and particle containment system, dental hand instrument delivery and control procedures, and the use of dental treatment materials. The initial efforts during the flight focused on verification of the efficiency of the particle containment system. An absorptive barrier was also tested in lieu of the suction collector. To test the instrument delivery system, teeth in the manikin were prepared with the dental drill to receive restorations, some with temporary filling materials and another with definitive filling material (composite resin). The best particle containment came from the combination use of the laminar-air/suction collector in concert with immediate area suction from a surgical high-volume suction tip. Lighting in the treatment area was provided by a flexible fiberoptic probe. This system is quite effective for small areas, but for general tasks ambient illumination is required. The instrument containment system (elastic cord network) was extremely effective and easy to use. The most serious problem with instrument delivey and actual treatment was lack of time during the microgravity sequences. The restorative materials handled and finished well.

Young, John↗

Fluid handling 2: Surgical applications

The methods proposed for managing fluids and particulate debris during minor surgery on Space Station Freedom (SSF) were investigated and demonstrated. A KC-135 parabolic flight test was performed, in which the flight followed the standard 40 parabola profile with 20 to 25 seconds in near-zero gravity in each parabola. The equipment (suction and laminar flow device) was evaluated. While this equipment performed satisfactorily previously in the dental simulation, the purpose of the current flight was to reconfigure the equipment in support of a minor surgical situation in order to evaluate its efficacy and establish clear requirements for the actual flight hardware. To accomplish the study the Health Maintenance Facility medical restraint system was deployed as for surgical use and mannequin suture arm was restrained to its surface. The surgical area was established as for performing minor surgery with standard tray and suture instruments employed.

Billica, Roger↗