A process to verify numerical models for seismic fluid-structure interaction in advanced reactor vessels

Seismic design and qualification of a liquid-filled advanced nuclear reactor will have to account for fluid-structure interaction (FSI). Interaction between the tank, internal components, and contained liquid will rely on analysis of numerical models that must be verified and validated. Here this study demonstrates a verification process for models of a base-supported cylindrical tank by comparing numerical predictions and analytical solutions. The numerical models are consistent with the assumptions made to derive analytical solutions, namely, either a rigid or a linear elastic tank, ideal fluid, and small-amplitude, unidirectional, horizontal inputs. One software platform is used to illustrate the process. Seismic FSI analysis is performed using the Arbitrary Lagrangian-Eulerian (ALE) and Incompressible Computational Fluid Dynamics (ICFD) solvers in LS-DYNA. Reported responses are those used for design, including hydrodynamic pressures on the tank wall, shear forces and moments at the tank base, and wave heights of the contained liquid. The accuracy of the numerical results is discussed. The numerical models are verified for calculating the pressures on the tank wall and reactions at its base. Accurate simulation of wave action is challenging for both solvers. Recommendations for modeling, code development, and steps for verification are provided. Although focused on reactor vessels and one software platform, the verification process described herein is broadly applicable to liquid-filled vessels and other finite element codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of numerical models for seismic fluid-structure-interaction analysis of nuclear, safety-related equipment

Seismic design, qualification, and risk assessment of nuclear safety-related vessels filled with liquid will have to consider the interaction between the vessel (tank), the contained liquid, and submerged components, if any. Seismic fluid-structure-interaction (FSI) analysis of nuclear vessels will rely on numerical models, which are required to be verified and validated. This study validates previously-verified numerical models using test data generated from earthquake-simulator experiments involving a cylindrical tank. Two solvers in LS-DYNA for FSI simulations are used for the numerical analysis: Arbitrary-Lagrangian-Eulerian (ALE) and Incompressible Computational Fluid Dynamics (ICFD). Numerical and test results are compared for responses critical to seismic design of advanced reactor vessels: hydrodynamic pressures on the tank wall, reactions at the support, and wave heights of the contained liquid. Analysis is performed for one-, two-, and three-directional seismic inputs with a range of intensity, and rocking motions. The accuracy of the numerical results and different methods for outputting wave heights are discussed. Recommendations for validation of seismic FSI numerical models of advanced reactors are provided. As a result, the validation exercise presented in this study is broadly applicable to cylindrical tanks, regardless of industry sector.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Review of analytical studies on seismic fluid-structure interaction of base-supported cylindrical tanks

Analytical solutions for seismic fluid-structure interaction (FSI) of tanks are used by analysts and engineers for a number of purposes, including preliminary sizing, risk assessment, and verification of numerical models. Analytical solutions for seismic FSI of tanks were first developed in the 1930s and have been extended and/or modified in the following nine decades to accommodate different seismic inputs and boundary conditions. This report reviews published analytical solutions for rigid and flexible, base-supported, cylindrical tanks subjected to unidirectional horizontal motion of a small amplitude. The studies parsed the fluid-structure (FSI) response into an impulsive and a convective component, and addressed frequencies of lateral motions of the tank (i.e., impulsive frequencies), hydrodynamic pressures, frequencies of waves (i.e., convective frequencies), wave heights, and reactions at the base. The solutions were categorized into exact and approximate solutions based on the methodologies used. Herein, FSI responses are calculated and compared for a range of tank dimensions using the analytical solutions from the different studies. The responses presented here are normalized to be unitless, and can be used for tanks with different dimensions and mechanical properties, and subjected to different input motions. A sample steel water tank is analyzed using the normalized solutions for two earthquake ground motions with different frequency contents. Ignoring tank flexibility may significantly underestimate seismic responses of the tank and its contained fluid. The approximate solutions, which have been widely used for decades, may not be sufficiently accurate in the modern era. Calculation errors in the reviewed studies are identified and corrected, and differences are quantified for the sample tank.

42 ENGINEERING↗

Rocking response of liquid-filled cylindrical tanks

The hydrodynamic response of liquid-filled storage tanks subjected to translational earthquake shaking has been the focus of studies for more than 75 years. In service, tanks experience six components of seismic input, with rocking due to support flexibility and/or rotational components of ground motion. Published theory for predicting hydrodynamic responses in rigid cylindrical tanks due to rotational seismic input is examined. Analytical solutions for pressure in the fluid and on the tank wall, and base moment are modified to account for the effects of angular displacements at the base. A finite element model of a water-filled cylindrical tank using the Arbitrary Lagrangian and Eulerian (ALE) solver in LS-DYNA is used to demonstrate the efficacy of the proposed expressions for three base rocking motions. Results from the modified analytical solutions and the finite element model are in excellent agreement.

58 GEOSCIENCES↗

Analytical Solutions for Seismic Fluid-Structure Interaction of Head-Supported Cylindrical Tanks

Fluid-structure interaction (FSI) of earthquake shaking is a design consideration in the civil, nuclear, chemical, and mechanical industries. Preliminary sizing of structures and components in these industries will often use analytical solutions because there is insufficient information to warrant the analysis of numerical models. Here, this study extends prior analytical work on seismic FSI of base-supported tanks in the 1980s to accommodate head-supported tanks with geometries similar to those proposed for new-build, liquid (fluid)-filled, advanced reactors. Analytical solutions are derived for flexible, head-supported, cylindrical tanks subjected to small-amplitude, unidirectional, horizontal seismic motion, and address frequencies of lateral motions of the tank, hydrodynamic pressures, frequencies of waves, wave heights, and reactions at the head support. Solutions are presented for a range of tank dimensions and could be used for a) preliminary design of head-supported cylindrical tanks and their supporting structures with idealized seismic input, and b) verification of numerical models to be used for final seismic analysis, design, and probabilistic risk assessment.

42 ENGINEERING↗