Publications and source records attributed to Yu, Li.

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

aggregates↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events: Preprint

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

IEEE 1547 2018↗

Kondo interaction in FeTe and its potential role in the magnetic order

Finding d-electron heavy fermion states has been an important topic as the diversity in d-electron materials can lead to many exotic Kondo effect-related phenomena or new states of matter such as correlation-driven topological Kondo insulator. Yet, obtaining direct spectroscopic evidence for a d-electron heavy fermion system has been elusive to date. Here, we report the observation of Kondo lattice behavior in an antiferromagnetic metal, FeTe, via angle-resolved photoemission spectroscopy, scanning tunneling spectroscopy and transport property measurements. The Kondo lattice behavior is represented by the emergence of a sharp quasiparticle and Fano-type tunneling spectra at low temperatures. The transport property measurements confirm the low-temperature Fermi liquid behavior and reveal successive coherent-incoherent crossover upon increasing temperature. We interpret the Kondo lattice behavior as a result of hybridization between localized Fe 3d xy and itinerant Te 5p z orbitals. Our observations strongly suggest unusual cooperation between Kondo lattice behavior and long-range magnetic order.

36 MATERIALS SCIENCE↗

Understanding Impacts of Frequency Calculations on Underfrequency Load Shedding

Power system fundamental frequency-dependent protection decisions and control decisions are increasingly common in the distribution system space. Understanding the algorithms used in frequency measurements is critical to understanding the decisions made by the many intelligent electronic devices in the power system. These decisions are critically important for reliability analysis for interconnected power systems as they bear directly on resource planning to mitigate under-frequency conditions that would result in under-frequency load shedding (UFLS). This work aims to improve the understanding of frequency measurement algorithms, evaluate the intelligent electronic devices that use frequency measurements for decision making, and understand the algorithms' direct impact on frequency related decision making. First, this work presents background information on the use of frequency measurements in protection logic, specifically UFLS. Second, the paper presents a relay hardware evaluation test bed used to detect and protect systems from under-frequency events. Finally, the paper presents the dynamic events used to evaluate commercially available, off-the-shelf relay equipment and the results from the relay evaluation.

COMTRADE↗

Projections of wildfire risk and activities under 1.5 °C and 2.0 °C global warming scenarios

Wildfires are important ecosystem processes that have a significant impact on terrestrial vegetation, environment, and climate. This study investigates how future wildfire risk and activities could change under 1.5 °C and 2.0 °C warming scenarios relative to pre-industrial levels using a modified McArthur Forest Fire Danger Index (FFDIn) and the CLM4.5-BGC land surface model. Sixteen Earth System Models (ESMs) from CMIP5 and CMIP6 were employed to supply the variables of climate change under low, middle, and high greenhouse emission scenarios in the 1.5 °C and 2.0 °C scenarios. The ensemble means from the FFDIn and results from the CLM4.5-BGC with multiple forcings show that the dry areas in the southwestern US, Brazilian Highlands, and Arabian islands are projected to face higher wildfire risk with larger burned areas and more carbon emissions under a warmer climate. The Congo Basin and part of the Amazon could have a lower wildfire risk with smaller burned areas and less carbon emissions. The absolute changes in the projected FFDIn are small, although large increases are observed in boreal areas, particularly in the winter and spring. Burned area and carbon emissions are projected to increase in general in the boreal area but decrease in northeastern Asia. Compared to the 1.5 °C scenario, the wildfire risk and burned area levels are projected to increase under the 2.0 °C scenario except in the western Amazon. However, fire carbon emissions are projected to decrease more in tropical areas under the 2.0 °C scenario. The different change directions in eastern North America and eastern China produced by the FFDIn and CLM4.5-BGC suggest the potential effect of non-meteorological elements on fire activities.

1.5 °C and 2.0 °C warming↗

Characterization of DER Momentary Cessation and Rate-of-Change-of-Frequency Response

Momentary cessation (MC) and response to rate-of-change-of-frequency (ROCOF) are inverter responses that can have serious impact on the stability of the grid during abnormal conditions. Though IEEE Std 1547-2018 provides fairly well defined expected responses from inverter-based DERs during abnormal grid conditions, a significant portion of currently installed DERs in the distribution network do not have a well defined response to abnormal grid conditions. Any analysis of the grid involving inverter MC and ROCOF response must consider the specific characteristics of these responses for the installed DERs to have better confidence in the analysis results, especially for grids with high levels of DERs. However, there is lack of information on MC and ROCOF response for the inverters already installed in the field. In this paper, we examine a large data set of installed inverters to map the dominant population of installed inverters. This information is then used to characterize the most dominant MC and ROCOF responses of installed inverters using experimental data.

DER↗

Operability of a Power System with Synchronous Condensers and Grid-Following Inverters

Growing shares of inverter-based resources gener-ally correlate with a reduction in inertia as synchronous genera-tors are displaced. Along the path to high shares of inverter-based resources, in particular with only conventional grid-following inverter controls, a proffered solution is the use of synchronous condensers as a source of inertia to maintain the frequency-power balance relationship. An outstanding question is whether only grid-following inverters and synchronous condensers yield a viable power system; i.e., all frequency response is derived from inverters. A validated electromagnetic transient model of the Maui system, with many nonlinear elements such as load-shedding, line tripping, and inverter ride through criteria disabled, is used to investigate the stability of such a system. Two types of perturbations were applied, a 15% generation loss and a fault event, and it was found that the system remains stable.

grid-following inverters↗

Stabilizing Inverter-Based Transmission Systems: Power Hardware-in-the-Loop Experiments with a Megawatt-Scale Grid-Forming Inverter

This article presents what the authors believe to be the first experimental verification of the ability of grid-forming (GFM) inverters to stabilize a transmission electric power system that is otherwise unstable. The experiments described here were performed using power hardware-in-the-loop (PHIL) simulation to connect a megawatt-scale battery inverter to a real-time electromagnetic transient (EMT) simulation of the near-future Maui power system. This allows the dynamic interactions between the inverter and the power system to be observed without putting the real power system at risk. The ability to use the actual inverter hardware removes the need to rely on a computer model approximation of the inverter's behavior.

electromagnetic transient simulations↗