Search NASA⌕ Search

Engineering topics

Yu, Lili

Publications and source records attributed to Yu, Lili.

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Transforming Windows from Energy Liabilities to Zero-Energy Assets: Next-Generation Solutions for Buildings

Windows have traditionally contributed to a building's HVAC load, but they can also become a source of net energy gain or even operate as zero-energy components. For heating applications, highly insulating windows can harness more solar heat than the energy lost through them, transforming windows from energy liabilities to assets. Dynamic glazings provide further benefits by regulating solar heat gain, reducing cooling loads in summer and heating demands in winter. This simulation study focuses on developing the next generation of zero-energy windows (ZEW) for residential new construction. Through annual energy simulations across climate zones 1-8, ZEW performance benchmarks were established based on current code-level buildings, and we've identified the regions where meeting ZEW standards are most achievable. This work evaluates both static and dynamic window technologies, assessing their effects on annual energy use and cost. Key findings demonstrate that ZEW performance is achievable across diverse climate zones, with specific regional requirements. Most climate zones from 3-8 can achieve ZEW with specific configurations, while some warm climates (1-2) appear challenging for ZEW implementation. Climate zones 4-6 consistently allow for zero energy window implementation, offering multiple pathways through either static or dynamic window technologies. Colder climate zones (7-8) ZEW products allow for higher SHGC values while requiring low U-values.

Yu, Lili↗

Factors Influencing Building Demand Flexibility

The U.S. Department of Energy’s National Roadmap for Grid-interactive Efficient Buildings (GEB) acknowledged that building demand flexibility (DF) is both an important strategy to decarbonizing the buildings sector and an important resource for meeting the changing needs of the electrical grid such as improving grid reliability. However, understanding the complexity and uncertainties in real building field performance of DF strategies is a large gap hindering stakeholders on both grid and buildings side to make investments on deploying such strategies. The research work in this report intended to advance understanding of the variability and influential factors in building demand flexibility. Adding such knowledge based on lab testing results and measured performance data from real buildings is an important contribution. The report uses standardized metrics and methods to quantify DF performance from field-measured DF datasets of two significant building groups of big-box retail and medium office buildings to present the challenge of building DF variability in multiple dimensions. The report presents findings related to how several key factors influence building demand flexibility from implementing a common, cost-effective DF control strategy (i.e., adjusting zone temperatures). The findings are supported by full-scale lab testing, field data analysis and simulation research. The authors also provided application-oriented recommendations to stakeholders such as building aggregators, utility program design professionals, sophisticated building portfolio owners, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining and applying an electricity demand flexibility benchmarking metrics framework for grid-interactive efficient commercial buildings

Building demand flexibility (DF) research has recently gained attention. To unlock building DF as a predictable grid resource, we must establish a quantitative understanding of the resource size, performance variability, and predictability based on large empirical datasets. Researchers have proposed various sets of theoretical metrics to measure this performance. Some metrics have been applied to simulation results, but most fall short of exploring the complexities in real building applications. There are practical metrics used in individual demand response field studies but they alone cannot fulfil the job of DF benchmarking across a diverse group of buildings. The electrical grid's geographically diverse and changing nature presents challenges to comparing building DF performance measured under different conditions (i.e., benchmarking DF). To address this challenge, a novel DF benchmarking framework focused on load shedding and shifting is presented; the foundation is a set of simple, proven single-event metrics with attributes describing event conditions. These enable benchmarking and visualization in different dimensions for identifying trends that represent how these attributes influence DF. To test its feasibility and scalability, the DF framework was applied to two case studies of 11 office buildings and 121 big-box retail buildings with demand response participation data. Furthermore, these examples provided a pathway for using both building level benchmarking and aggregation to extract insights into building DF about magnitude, consistency, and influential factors. Potential applications of the framework and real-world values have been identified for grid and building stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

When Do Efficiency and Demand Flexibility Go Hand-in-hand?

Utilities have been experimenting with integrated demand side management (IDSM) programs since the 2000s. The potential benefits of improved program cost-effectiveness and customer engagement from combining energy efficiency (EE), demand flexibility (DF), and other distributed energy resources into an integrated customer offering have been recognized although there are several known regulatory and program administrative challenges. In addition, as buildings adopt EE measures, the baseline load profile change generally reduces the potential load that can be shed or shifted. This has been a significant technical barrier for customers and program implementers. However, it is a myth that EE always reduces DF. Load change from EE can be time-varying. Therefore, whether EE improves or reduces DF should be evaluated on an individual measure basis accounting for weather dependencies and interactions. For IDSM program design purpose, it is useful to understand how common EE features influence DF and the underlying building physics. In this paper, we use parametric simulations of a prototype medium office building to evaluate how various EE features influence DF, measured by a “demand decrease intensity” (W/ft2) metric. These EE features cover envelope characteristics, internal loads, and airside HVAC system. The parametric analysis shows that some efficient HVAC control measures will increase DF but not the traditional building envelope, lighting, and ventilation-related efficiency measures. These findings contribute to the technical basis for achieving enhanced energy benefits by packaging appropriate HVAC control measures in IDSM program design. Program developers should further validate these results in targeted pilot projects.

Yu, Lili↗

Benchmarking Demand Flexibility in Commercial Buildings and Flattening the Duck – Addressing Baseline and Commissioning Challenges

With the transition from our traditional electric grid to a cleaner grid with renewable power generation, there is a need to enable building loads to be flexible. Load shedding and shifting will be essential for flattening the “Duck” for decarbonization. This paper explored the trend in the timing of DR events as a reflection of the grid’s needs using recent four years of event data from 203 retail stores in 11 states. The events are becoming significantly shorter with 2-hour duration being the most popular; shifting to late afternoon and early evening is another trend beyond California. Benchmarking will be essential for accounting DF as a reliable grid resource. This paper addresses a challenging aspect of benchmarking – inaccuracies in counterfactual baseline methods can introduce significant DF metrics variations in addition to weather and building characteristics related factors. The conventional “10/10” with adjustment baseline method has inherent limitation by design for load shifting applications. Therefore, it is imperative to identify alternative methods. This study compared three hourly regression baseline methods with “10/10” methods using two groups of commercial buildings that participated in DR programs: (1) 121 big-box retail stores, and (2) 11 office buildings in CA. The 14-day hourly outdoor temperature regression method was found to produce least error in the tested datasets and is promising for load shifting. The paper also pointed out that commissioning issues can also be a significant barrier for achieving consistent DF performance, which building managers and utilities should be aware of.

Liu, Jingjing↗