A Bidirectional Isolated Dual-Phase-Shift Variable-Frequency Series Resonant Dual-Active-Bridge GaN AC–DC Converter
Not provided.
Engineering topics
Publications and source records attributed to Yu, Ruiyang.
Not provided.
Not provided.
Not provided.
An accurate estimation of spatially and temporally continuous global terrestrial evapotranspiration (ET) is essential in the assessment of surface energy, water and carbon cycles. The Global LAnd Surface Satellite (GLASS) ET product Version 4.0 (v4.0) based on the Bayesian model averaging (BMA) method was generated to estimate global terrestrial ET. However, certain uncertainty for the GLASS ET product v4.0 limits its application. In this study, we introduced the deep neural networks (DNN) merging framework to improve terrestrial ET estimation for GLASS ET product Version 5.0 (v5.0) generation by integrating five satellite-derived ET products [Moderate Resolution Imaging Spectroradiometer (MODIS) ET product (MOD16), Shuttleworth–Wallace dual-source ET product (SW), Priestley–Taylor-based ET product (PT-JPL), modified satellite-based Priestley–Taylor ET product (MS-PT) and simple hybrid ET product (SIM)]. We compared the performance of DNN method against other merging methods, including GLASS ET algorithm v4.0 (BMA), the gradient boosting regression tree (GBRT) method and the random forest (RF) method, based on 195 global eddy covariance (EC) flux towers covering observations from 2000 through 2015. Validations indicated that the DNN had the highest accuracy among four merging methods across different land cover types, yielding the highest average determination coefficients (R 2 , 0.62), root-mean-squared-error (RMSE, 24.1 W/m 2 ) and Kling–Gupta efficiency (KGE, 0.77) with a of 99% confidence interval. Compared with GLASS ET algorithm v4.0, the DNN improved on the R 2 by approximately 7% (p < 0.01) and the KGE by 10%. Based on the DNN, we then generated 8-day GLASS ET product v5.0 globally with a 1 km spatial resolution from 2001 to 2015 driven by GLASS vegetation and surface net radiation (R n ) datasets and Modern-Era Retrospective Analysis for Research and Applications, Version 2 (MERRA2) datasets. Finally, this global terrestrial ET product provides a valuable dataset for monitoring regional and global water resources and environmental changes.
This paper presents a loss-optimized Triple Phase-Shift (TPS) switching strategy for Dual-Active Bridge (DAB) based converters. The proposed strategy considers minimizing total converter loss with respect to minimizing device rms cur-rents, enabling Zero-Voltage Switching (ZVS) turn-on of devices and accurate control of device turn-off current. A model for switching currents is presented, followed by a loss model and optimization strategy. A 1.3kV/100kW prototype based on SiC MOSFETs was used in this work and experimental results up to 10kW show the proposed TPS strategy to be more efficient for operation.
This paper presents a lossless regenerative dV/dt snubber circuit for PWM converters to achieve high-efficiency high power-density without significant cost and reliability penalties. The dV/dt snubber employs lossless capacitors for each MOSFET device in a converter to provide an additional path to store the switching energy during turn-off transient and decrease the actual turn-off loss of the MOSFET channel. A novel mathematical turn-off loss model is built to separate the actual turn-off loss of the MOSFET channel and the recycling switching energy stored in the total equivalent output capacitance including Coss, the dV/dt snubber, and etc. Necessary snubber optimization strategy is proposed in order to balance the turn-off loss with ZVS operation range and deadtime conduction loss, and thereby achieving an optimal efficiency performance. To prove the validity and accuracy of the novel turn-off loss model and optimization strategy, the dV/dt snubber has been incorporated into a 1.3kV/200kW DC/DC and a 1kV/70kVA DC/AC PWM converters. Experimental results are given to demonstrate the validity of the proposed dV/dt snubber capacitors and optimization strategy.
This paper presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.
This paper describes a thermal design using epoxy potting for high frequency transformer (HFT) for medium voltage high power electronic applications, namely emerging solid-state transformers. To address HFT’s thermal stress problem, thermal performance of the HFT with air and epoxy potting cooling method are both simulated by magnetothermal-fluid coupling method (MTFCM). The effectiveness of the simulation analysis is verified in a 100 kW DC-DC resonant converter. Influencing factors including distance between the high frequency transformer and the metal enclosure, epoxy thermal conductivity and heat sink placements are simulated and analyzed. Finally, an optimal cooling structure is proposed for future high power HFTs.
This paper presents a single-stage series-resonant dual active half bridge (SR-DAHB) inverter suitable for high power applications. The topology is an isolated dual half-bridge circuit with an unfolding bridge. A combined phase-shift and frequency modulation technique is utilized to generate AC power output. In high-power applications where the switching devices operate at relatively high current and voltage, the switching loss becomes the major portion of the converter’s total loss as the devices are turned on and off under hard switching condition. The primary merit of the proposed single-stage SR-DAHB inverter with the combined phase-shift and frequency modulation control is to significantly reduce the switching loss so that it is not a function of load current. A precise and comprehensive power loss model is developed for both the SR-DAHB and DAHB to optimize the operation of the inverters. The objective of the optimization is to minimize the inverter total loss while calculating the optimum combination of frequency and phase shift. A 1.5 kV, 50 kW prototype was built to demonstrate the performance of the SRDAHB versus DAHB inverters with the combined phase-shift and frequency modulation control, and validate the theoretical analysis.
High efficiency, high density and galvanically isolated power converters are attractive for numerous medium voltage high power applications. This paper presents a 1.5kVdc, 100kW bidirectional Dual Active Half Bridge (DAHB) using newly developed 1.7kV SiC MOSFET modules. The DAHB achieved an efficiency of 98.6% at full load of 100kW and a maximum of 99% at 45kW, operating as an isolated DC/DC converter. The converter also achieved an efficiency of 97.8% operating as an isolated DC/AC inverter. An optimized PCB-based busbar design has significantly reduced the voltage overshoot across the device, making the design suitable for 1500Vdc input application such as 1500V PV inverters. Typical partial discharge inception voltage (PDIV) of the optimized PCB busbar is 1.7kVpeak with total charge <10pC. The power density of the DAHB converter is 1.8MVA/m 3 which is much higher than traditional two-stage industry products. The DAHB converter can be used as a building block for a 4.16kV/1MVA utility scale PV systems with input parallel and output series configuration.