Search NASA⌕ Search

Engineering topics

Yuan, X. L.

Publications and source records attributed to Yuan, X. L..

Lithium splashing from flowing liquid lithium limiter and its effect on high confinement plasma performance in EAST tokamak

To study the potential applications of liquid lithium (Li) as plasma facing material, the third generation of flowing liquid Li (FLiLi) limiter has been designed and successfully tested in EAST tokamak H-mode discharges in the 2018 run campaign. Here, the stability of liquid Li on FLiLi surface, and Li splashing and its effect on the plasma performance are investigated in detail. Li splashing was observed in L-mode and H-mode discharges due to Rayleigh-Taylor (R-T) instability, resulting from electromagnetic forces J → x B → . Li splashing in low-parameter plasma decreased both core and edge electron temperatures, resulting in the degradation of plasma energy confinement and even H-L back transition, however, it almost did not influence plasma confinement performance in high-parameter plasma. These findings indicate that high-parameter plasma has higher tolerance to Li impurities than low-parameter plasma. By contrast, tungsten splashing from the melted layer on the upper divertor was also induced by the R-T instability but generally resulted in plasma disruption, which suggests lower tolerance to tungsten impurities in EAST tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Corrosion of 304 stainless steel in static liquid lithium under high vacuum

To study the compatibility especially the corrosion characteristic of structural material stainless steel (SS) with liquid lithium (Li) is an important factor for the simultaneous application of liquid Li and SS as a blanket material or potential plasma facing material (PFM) in future fusion devices. Here, the corrosion behaviors of 304SS exposed to liquid Li at 700 K for 1320 hr under high vacuum were investigated. After exposure to liquid Li, 304SS produces non-uniform corrosion which includes corrosion products and grain boundary corrosion. Compared with the corrosion behaviors at 600 K and 640 K, temperature plays an important role in the corrosion behaviors of 304SS in static liquid Li. The weight loss, corrosion depth and corrosion products of 304SS specimens increase with the corrosion temperature. In general, the compatibility between 304SS and static liquid Li is relatively good under the experimental conditions. And besides, it is unexpectedly found that the compatibility of copper with Li is not good.

304SS↗

Real-time gas cooling of flowing liquid lithium limiter for the EAST

A novel continuously flowing liquid lithium limiter (FLiLi) which employs an in-vessel electro-magnetic pump to drive liquid Li flowing on the surface of limiter has been successfully designed and tested in the experimental advanced superconducting tokamak (EAST) device in 2014. In order to better control the surface temperature, an upgraded design and the real-time gas cooling were performed in 2016. Two kinds of cooling gas, helium (He) and argon (Ar) were tested on the FLiLi system prior to the experiment. It was found that the cooling rates of He and Ar at 2.5 MPa are 34.2 °C/min, 10.2 °C/min or 31.7 °C/kL and 28.1 °C/kL, respectively. The cooling performance of He is more effective than Ar. Experimental results show that the real-time He cooling could effectively contain the FLiLi surface temperature increase and prevent the strong passive evaporation of lithium during plasma discharges. Limiter heat flux up to 0.2 MW/m2 was removed during ohmic discharge with 2.5 MPa He gas. Finally, Because of the upgraded design and real-time gas cooling, the surface of FLiLi was not damaged by heat flux after entire plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results from an improved flowing liquid lithium limiter with increased flow uniformity in high power plasmas in EAST

Significant engineering and physic progress was made by the upgrade of a flowing liquid lithium limiter (FLiLi) inserted into EAST H-mode discharges in 2016. The progress includes an improvement of liquid Li coverage uniformity, no macroscopic surface erosion by plasma materials interaction, effective removal of 55% of the discharge heat flux using high pressure He cooling during ohmic discharges, and the demonstrated ability to restart Li flow for a second experiment performed a week after the first. With increasing Li flow rate, fuel particle recycling and Fe impurity radiation gradually decreased, and plasma performance slightly improved, but there was no impact on the edge tungsten influx. No obvious Li bursts appeared during operation with up to about 4.5 MW auxiliary heating power with peak heat flux reaching ~4 MW m –2 on FLiLi. In addition, a gradual mitigation of edge localized mode (ELM) activity was observed with FLiLi operation. Lastly, short-lived ELM-free phases were observed for the first time in EAST during FLiLi insertion, with increasing τ E and transient H 98(y, 2) < 2.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgraded flowing liquid lithium limiter for improving Li coverage uniformity and erosion resistance in EAST device

In this paper, we report on design and technology improvements for a flowing liquid lithium (FLiLi) limiter inserted into auxiliary heated discharges in the experimental advanced superconducting tokamak device. In order to enhance Li coverage uniformity and erosion resistance, a new liquid Li distributor with homogenous channels was implemented. In addition, two independent electromagnetic pumps and a new horizontal capillary structure contributed to an improvement in the observed Li flow uniformity (from 30% in the previous FLiLi design to >80% in this FLiLi design). To improve limiter surface erosion resistance, hot isostatic press technology was applied, which improved the thermal contact between thin stainless steel protective layers covering the Cu heat sink. The thickness of the stainless steel layer was increased from 0.1 mm to 0.5 mm, which also helped macroscopic erosion resilience. Finally, despite the high auxiliary heating power up to 4.5 MW, no Li bursts were recorded from FLiLi, underscoring the improved performance of this new design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗