A Data-Driven Framework for Power System Event Type Identification via Safe Semi-Supervised Techniques

Herein this paper investigates the use of phasor measurement unit (PMU) data with deep learning techniques to construct real-time event identification models for transmission networks. Increasing penetration of distributed energy resources represents a great opportunity to achieve decarbonization, as well as challenges in systematic situational awareness. When high-resolution PMU data and sufficient manually recorded event labels are available, the power event identification problem is defined as a statistical classification problem that can be solved by numerous cutting-edge classifiers. However, in real grids, collecting tremendous high-quality event labels is quite expensive. Utilities frequently have a large number of event records without in-depth details (i.e., unlabeled events). To bridge this gap, we propose a novel semi-supervised learning-based method to improve the performance of event classifiers trained with a limited number of labeled events by exploiting the information from massive unlabeled events. In other words, compared to existing data-driven methods, our method requires only a small portion of labeled data to achieve a similar level of accuracy. Meanwhile, this work discusses and addresses the performance degradation caused by class distribution mismatch between the training set and the real applications. Based on the proposed safe learning mechanism, our model does not directly use all unlabeled events during model training, but selectively uses them through a comprehensive evaluation procedure. Numerical studies on a sizable PMU dataset have been used to validate the performance of the proposed method.

42 ENGINEERING↗

Singular Perturbation-Based Large-Signal Order Reduction of Microgrids for Stability and Accuracy Synthesis With Control

The increasing penetration of distributed energy resources (DERs) highlights the growing importance of microgrids (MGs) in enhancing power system reliability. Employing electromagnetic transient (EMT) analysis in MGs becomes crucial for controlling the rapid transients. However, this requires an accurate but high-order model of power electronics and their underlying control loops, complexifying the stability analysis from the viewpoint of a higher control level. To overcome these challenges, this paper proposes a large-signal order reduction (LSOR) method for MGs with considerations of external control inputs and the detailed dynamics of underlying control levels based on singular perturbation theory (SPT). Specially, we innovatively proposed and strictly proved a general stability and accuracy assessment theorem that allows us to analyze the dynamic stability of a full-order nonlinear system by only leveraging our derived reduced-order model (ROM) and boundary layer model (BLM). Furthermore, this theorem furnishes a set of conditions that determine the accuracy of the developed ROM. Lastly, by embedding such a theorem into the SPT, we propose a novel LSOR approach with guaranteed accuracy and stability analysis equivalence. Case studies are conducted on MG systems to show the effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning Latent Interactions for Event Identification via Graph Neural Networks and PMU Data

Phasor measurement units (PMUs) are being widely installed on power systems, providing a unique opportunity to enhance wide-area situational awareness. One essential application is the use of PMU data for real-time event identification. However, how to take full advantage of all PMU data in event identification is still an open problem. Thus, we propose a novel method that performs event identification by mining interaction graphs among different PMUs. The proposed interaction graph inference method follows an entirely data-driven manner without knowing the physical topology. Moreover, unlike previous works that treat interactive learning and event identification as two different stages, our method learns interactions jointly with the identification task, thereby improving the accuracy of graph learning and ensuring seamless integration between the two stages. Moreover, to capture multi-scale event patterns, a dilated inception-based method is investigated to perform feature extraction of PMU data. To test the proposed data-driven approach, a large real-world dataset from tens of PMU sources and the corresponding event logs have been utilized in this work. We report numerical results validate that our method has higher classification accuracy compared to previous methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Learning of Dynamic Interactions for Enhancing Power System Resilience (Final Scientific Report)

The overall goal of the project is to leverage robust graphical learning and phase measurement unit (PMU) data to learn the dynamic interactions of electrical grid components in order to improve the power system resilience. Specifically, the learned dynamic interaction graphs are utilized to detect known and unknown anomalous patterns in power systems, identify high-risk operational conditions, and enable risk-based cascading mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multisource Data Fusion Outage Location in Distribution Systems via Probabilistic Graphical Models

Efficient outage location is critical to enhancing the resilience of power distribution systems. However, accurate outage location requires combining massive evidence received from diverse data sources, including smart meter (SM) last gasp signals, customer trouble calls, social media messages, weather data, vegetation information, and physical parameters of the network. This is a computationally complex task due to the high dimensionality of data in distribution grids. In this paper, we propose a multi-source data fusion approach to locate outage events in partially observable distribution systems using Bayesian networks (BNs). A novel aspect of the proposed approach is that it takes multi-source evidence and the complex structure of distribution systems into account using a probabilistic graphical method. Our method can radically reduce the computational complexity of outage location inference in high-dimensional spaces. The graphical structure of the proposed BN is established based on the network’s topology and the causal relationship between random variables, such as the states of branches/customers and evidence. Utilizing this graphical model, accurate outage locations are obtained by leveraging a Gibbs sampling (GS) method, to infer the probabilities of de-energization for all branches. Compared with commonly-used exact inference methods that have exponential complexity in the size of the BN, GS quantifies the target conditional probability distributions in a timely manner. As a result, a case study of several real-world distribution systems is presented to validate the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Grid Modeling Using Smart Meter Data

The knowledge of distribution grid models, including topologies and line impedances, is essential for grid monitoring, control and protection. However, such information is often unavailable, incomplete or outdated. The increasing deployment of smart meters (SMs) provides a unique opportunity to tackle this issue. This paper proposes a two-stage framework for distribution grid modeling using SM data. In the first stage, the network topology is identified by reconstructing a weighted Laplacian matrix of distribution networks. In the second stage, a least absolute deviations (LAD) regression model is developed for estimating line impedance of a single branch based on the nonlinear (inverse) power flow model, wherein a conductor library is leveraged to narrow down the solution space. The LAD regression model is originally a mixed-integer nonlinear program whose continuous relaxation is still non-convex. Furthermore, we specially address its convex relaxation and discuss the exactness. The modified regression model is then embedded within a bottom-up sweep algorithm to achieve the identification across the network in a branch-wise manner. Numerical results on the IEEE 13-bus, 37-bus and 69-bus test feeders validate the effectiveness of the proposed methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear Multiple Models Adaptive Secondary Voltage Control of Microgrids

This article proposes a model-free secondary voltage control (SVC) for microgrids (MG) using nonlinear multiple models adaptive control. Firstly, a linear robust adaptive controller is designed to guarantee the voltage stability in the bounded-input- bounded-output (BIBO) manner so as to meet the operation requirements of MGs. Secondly, a nonlinear adaptive controller is developed to improve the voltage tracking performance with the help of artificial neural networks (ANNs). A switching mechanism for coordinating such two controllers is designed to guarantee the closed-loop stability while achieving accurate voltage tracking. Here, by an online identification based on the input and output data of MGs, the proposed method does not resort to any apriori information of system model and primary control, thus exhibiting good robustness, ease of deployment and disturbance rejection.

17 WIND ENERGY↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning-Based Real-Time Event Identification Using Rich Real PMU Data

A large-scale deployment of phasor measurement units (PMUs) that reveal the inherent physical laws of power systems from a data perspective enables an enhanced awareness of power system operation. However, the high-granularity and non-stationary nature of PMU data and imperfect data quality could bring great technical challenges for real-time system event identification. To address these challenges, this paper proposes a two-stage learning-based framework. In the first stage, a Markov transition field (MTF) algorithm is exploited to extract the latent data features by encoding temporal dependency and transition statistics of PMU data in graphs. Then, a spatial pyramid pooling (SPP)-aided convolutional neural network (CNN) is established to efficiently and accurately identify power events. The proposed method fully builds on and is also tested on a large real-world dataset from several tens of PMU sources (and the corresponding event logs), located across the U.S., with a time span of two consecutive years. We report the numerical results validate that our method has high identification accuracy while showing good robustness against poor data quality.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Disaggregating Customer-Level Behind-the-Meter PV Generation Using Smart Meter Data and Solar Exemplars

Customer-level rooftop photovoltaic (PV) has been widely integrated into distribution systems. In most cases, PVs are installed behind-the-meter (BTM), and only the net demand is recorded. Therefore, the native demand and PV generation are unknown to utilities. Separating native demand and solar generation from net demand is critical for improving grid-edge observability. In this paper, a novel approach is proposed for disaggregating customer-level BTM PV generation using low-resolution but widely available hourly smart meter data. The proposed approach exploits the strong correlation between monthly nocturnal and diurnal native demands and the high similarity among PV generation profiles. First, a joint probability density function (PDF) of monthly nocturnal and diurnal native demands is constructed for customers without PVs, using Gaussian mixture modeling (GMM). Deviation from the constructed PDF is utilized to probabilistically assess the monthly solar generation of customers with PVs. Then, to identify hourly BTM solar generation for these customers, their estimated monthly solar generation is decomposed into an hourly timescale; to do this, we have proposed a maximum likelihood estimation (MLE)-based technique that utilizes hourly typical solar exemplars. Leveraging the strong monthly native demand correlation and high PV generation similarity enhances our approach's robustness against the volatility of customers’ hourly load and enables highly-accurate disaggregation. Furthermore, the proposed approach has been verified using real native demand and PV generation data.

14 SOLAR ENERGY↗

Quantifying Load Uncertainty Using Real Smart Meter Data

As we get closer to customers in distribution systems, load stochasticity increases. In the past, due to lack of real-time data, the comprehensive knowledge of load behavior was limited, and simplistic assumptions had to be made for distribution system modeling and analysis, especially in the processes of network design and expansion. With the deployment of Advanced Metering Infrastructure (AMI), ample real-time smart meter data has become available to utilities. In this paper, using real hourly smart meter data, we have quantified load uncertainty in terms of average, maximum and maximum noncoincident demands on a daily basis, as well as load factor and diversity factor. These uncertainty metrics are examined for individual residential, commercial and industrial customers, as well as distribution transformers serving residential customers. This paper provides a benchmark on load uncertainty quantification for practicing engineers and researchers.