Irreversible synthesis of an ultrastrong two-dimensional polymeric material
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Yuan, Z..
Explore the source record for details and available documents.
The Sagittarius dwarf spheroidal (Sgr) is a dissolving galaxy being tidally disrupted by the Milky Way (MW). Its stellar stream still poses serious modelling challenges, which hinders our ability to use it effectively as a prospective probe of the MW gravitational potential at large radii. Our goal is to construct the largest and most stringent sample of stars in the stream with which we can advance our understanding of the Sgr-MW interaction, focusing on the characterization of the bifurcations. We improved on previous methods based on the use of the wavelet transform to systematically search for the kinematic signature of the Sgr stream throughout the whole sky in the Gaia data. We then refined our selection via the use of a clustering algorithm on the statistical properties of the colour-magnitude diagrams. Our final sample contains more than 700 000 candidate stars and is three times larger than previous Gaia samples. With it, we have been able to detect the bifurcation of the stream in both the northern and southern hemispheres, which requires four branches (two bright and two faint) to fully describe the system. We present the detailed proper motion distribution of the trailing arm as a function of the angular coordinate along the stream, showing, for the first time, the presence of a sharp edge (on the side of the small proper motions) beyond which there are no Sgr stars. We also characterize the correlation between kinematics and distance. Finally, the chemical analysis of our sample shows that the faint branch of the bifurcation is more metal poor than the bright. We provide analytical descriptions for the proper motion trends as well as for the sky distribution of the four branches of the stream. Based on our analysis, we interpret the bifurcations as a misaligned overlap of the material stripped at the antepenultimate pericentre (faint branches) with the stars ejected at the penultimate pericentre (bright branch), given that Sgr just went through its perigalacticon. The source of this misalignment is still unknown, but we argue that models with some internal rotation in the progenitor – at least during the time of stripping of the stars that are now in the faint branches – are worth exploring.
Using first-principles transport calculations, we predict that the anisotropic magnetoresistance (AMR) of single-crystal CoxFe1-x alloys is strongly dependent on the current orientation and alloy concentration. An intrinsic mechanism for AMR is found to arise from the band crossing due to magnetization-dependent symmetry protection. These special k points can be shifted towards or away from the Fermi energy by varying the alloy composition and hence the exchange splitting, thus allowing AMR tunability. The prediction is confirmed by delicate transport measurements, which further reveal a reciprocal relationship of the longitudinal and transverse resistivities along different crystal axes.
Not Available
The effect of cryogenic treatment on the plastic property of Ti-6Al-4V plate was studied in the present work. After cryogenic treatment, the low temperature temper at 180 ▭ was conducted in one of the groups and the results were compared with that of the untreated and cryotreated ones. The SLX series program controlled cryogenic equipment was used for the cryogenic treatment. The tensile tests were conducted by universal tensile testing machine and parameters of elongation and area reduction were used to evaluate plastic property. The scanning electron microscope was used to study the morphology of microstructure and fracture surface. The results show that after cryogenic treatment alone the elongation increased 10.6% and the area reduction increased 13.5% while the strength reduced to a small extent. Cryogenic treatment followed with low temperature temper increased the elongation and area reduction just by the extent of 4.7% and 9.5%. It means that the additional low temperature temper after cryogenic is not beneficial to the tensile properties of Ti-6Al-4V alloy. The examination of microstructure by scanning electron microscopy revealed that cryogenic treatment reduced the content of β phase particles which is the main reason for the improvement in plasticity.
In this paper, we describe an InGaAs detector based radiation thermometer (IRT) and new design of fixed-point blackbodies, including Sn, Zn, Al and Cu, for the establishment of a temperature scale from 200 °C to 1085 °C at the National Institute of Metrology of China. The construction and calibration of the IRT with the four fixed-point blackbodies are described. Characteristics of the IRT, such as the size-of-source effect, the amplifier performance and its stability are determined. The design of the four fixed-points, with 10 mm diameter of aperture and 0.9999 emissivity, is described. The uncertainty of the scale realization is elaborated.
The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.3×10{sup −3} at 633 nm and 900 nm, respectively.
This paper describes a comparison between PTB and NIM in the field of absolute spectral-band radiometry and thermodynamic temperature measurement. For the comparison a NIM made interference filter radiometer with a centre wavelength of 633 nm was taken to PTB. The filter radiometer was calibrated at NIM and PTB with respect to spectral irradiance responsivity. For the integral value in the band-pass range an agreement of 0.1% was observed in both calibrations. In a next step, the 633 nm filter radiometer was used to measure the temperature of a high-temperature blackbody in comparison to an 800 nm filter radiometer of PTB in the temperature range between 1400 K and 2750 K. The thermodynamic temperature measured by the two filter radiometers agreed to within 0.2 K to 0.5 K with an estimated measurement uncertainty ranging between 0.1 K and 0.4 K (k=1)
Three WC-C peritectic fixed point cells, constructed from different sources of tungsten with different nominal purities, were measured at NIM and NMIJ. The three cells were constructed at NMIJ by NIM and NMIJ staffs, and T{sub 90} values of the three cells were measured at NMIJ during the period 31 Aug. to 25 Dec. 2009. Thereafter, the three cells were then transported to NIM, and T{sub 90} values of these cells were measured from 7 Dec. 2011 to 9 Jan. 2012. The results showed that T{sub 90} values of the three cells measured at the two institutes agreed within 0.4 °C with the combined scale comparison uncertainty of 1.7 °C (k= 2). The main component of the uncertainty is not the uncertainty due to impurities of the cells but the scale uncertainty and the stability of the measurement system. From these results it can be concluded that the WC-C cell is stable enough to provide new means of international high-temperature scale comparison above 3000 K.
Abstract Not Provided
Experimental work on the effects of heat flux, oxygen concentration and glass fiber volume fraction on pyrolysate mass flux from samples of polypropylene/glass fiber composite (PP/G) is underway. The research is conducted as part of a larger project to develop a test methodology for flammability of materials, particularly composites, in the microgravity and variable oxygen concentration environment of spacecraft and space structures. Samples of PP/G sized at 30 x 30 x 10 mm are flush mounted in a flow tunnel, which provides a flow of oxidizer over the surface of the samples at a fixed value of 1 m/s and oxygen concentrations varying between 18 and 30%. Each sample is exposed to a constant external radiant heat flux at a given value, which varies between tests from 10 to 24 kW/sq m. Continuous sample mass loss and surface temperature measurements are recorded for each test. Some tests are conducted with an igniter and some are not. In the former case, the research goal is to quantify the critical mass flux at ignition for the various environmental and material conditions described above. The later case generates a wider range of mass flux rates than those seen prior to ignition, providing an opportunity to examine the protective effects of blowing on oxidative pyrolysis and heating of the surface. Graphs of surface temperature and sample mass loss vs. time for samples of 30% PPG at oxygen concentrations of 18 and 21% are presented in the figures below. These figures give a clear indication of the lower pyrolysis rate and extended time to ignition that accompany a lower oxygen concentration. Analysis of the mass flux rate at the time of ignition gives good repeatability but requires further work to provide a clear indication of mass flux trends accompanying changes in environmental and material properties.
Experimental work on the effects of heat flux, oxygen concentration and glass fiber volume fraction on pyrolysate mass flux from samples of polypropylene/glass fiber composite (PP/G) is underway. The research is conducted as part of a larger project to develop a test methodology for flammability of materials, particularly composites, in the microgravity and variable oxygen concentration environment of spacecraft and space structures. Samples of PP/G sized at 30x30x10 mm are flush mounted in a flow tunnel, which provides a flow of oxidizer over the surface of the samples at a fixed value of 1 m/s and oxygen concentrations varying between 18 and 30%. Each sample is exposed to a constant external radiant heat flux at a given value, which varies between tests from 10 to 24 kW/m2. Continuous sample mass loss and surface temperature measurements are recorded for each test. Some tests are conducted with an igniter and some are not. In the former case, the research goal is to quantify the critical mass flux at ignition for the various environmental and material conditions described above. The later case generates a wider range of mass flux rates than those seen prior to ignition, providing an opportunity to examine the protective effects of blowing on oxidative pyrolysis and heating of the surface. Graphs of surface temperature and sample mass loss vs. time for samples of 30% PPG at oxygen concentrations of 18 and 21% are presented in the figures below. These figures give a clear indication of the lower pyrolysis rate and extended time to ignition that accompany a lower oxygen concentration. Analysis of the mass flux rate at the time of ignition gives good repeatability but requires further work to provide a clear indication of mass flux trends accompanying changes in environmental and material properties.
The Forced Ignition and Spread Test (FIST) is being used to study the flammability characteristics of combustible materials in forced convective flows. The FIST methodology is based on the ASTM E-1321, Lateral Ignition and Flame Spread Test (LIFT) which is used to determine the ignition and flame spread characteristics of materials, and to produce 'Flammability Diagrams' of materials. The LIFT apparatus, however, relies on natural convection to bring air to the combustion zone and the fuel vapor to the pilot flame, and thus cannot describe conditions where the oxidizer flow velocity may change. The FIST on the other hand, by relying on a forced flow as the dominant transport mechanism, can be used to examine variable oxidizer flow characteristics, such as velocity, oxygen concentration, and turbulence intensity, and consequently has a wider applicability. Particularly important is its ability to determine the flammability characteristics of materials used in spacecraft since in the absence of gravity the only flow present is that forced by the HVAC of the space facility. In this paper, we report work on the use of the FIST approach on the piloted ignition of a blended polypropylene fiberglass (PP/GL) composite material exposed to an external radiant flux in a forced convective flow of air. The effect of glass concentration under varying external radiant fluxes is examined and compared qualitatively with theoretical predictions of the ignition process. The results are used to infer the effect of glass content on the fire safety characteristics of composites.