Study of Different Piezoelectric Material Stroke Displacement at Different Temperatures Using an SRF Cavity

Piezoelectric actuators are used for resonance control in superconducting linacs. The level of frequency compensation depends on the piezoelectric stroke displacement. In this study, the stroke displacement will be measured with a 1.3 GHz SRF cavity by measuring the frequency shift with respect to the voltage applied. The entire system was submerged in liquid helium. This study characterizes the PZT piezoelectric actuator (P-844K093) and a lithium niobate (P-844B0005) piezoelectric actuator. All these actuators were developed at Physik Instrumente (PI). The piezoelectric displacement was measured at different temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulated Lorentz Force Detuning Compensation With A Double Lever Tuner On A Dressed ILC/1.3 GHZ Cavity At Room Temperature

Pulsed SRF linacs with high accelerating gradients experience large frequency shifts caused by Lorentz force detuning (LFD). A piezoelectric actuator with a resonance control algorithm can maintain the cavity frequency at the nominal level, thus reducing the RF power. This study uses a double lever tuner with a piezoelectric actuator for compensation and another piezoelectric actuator to simulate the effects of the Lorentz force pulse. A double lever tuner has an advantage by increasing the stiffness of the cavity-tuner system, thus reducing the impact of LFD. The tests are conducted at room temperature and with a dressed 1.3 GHz 9-cell cavity.

43 PARTICLE ACCELERATORS↗

Tests Of The Extended Range SRF Cavity Tuners For The LCLS-II-HE Project*

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in the verification cryomodule (vCM) and CM 1 at Fermilab at 2 K. In both cases, the tuners achieved a frequency shift of -565$\pm$80 kHz. This study will discuss cavity frequency during each step as it is being assembled in the cryomodule string and finally when it is being tested at 2 K. Tracking the cavity frequency helped enable the tuners to reach this large frequency shift. The specific procedures of tuner setting during assembly will be presented.

43 PARTICLE ACCELERATORS↗

Accelerated Lifetime Test of the SRF Dressed Cavity/Tuner System for LCLS II HE Project

The off-frequency detune method is being considered for application in the LCLS-II-HE superconducting linac to produce multi-energy electron beams for supporting multiple undulator lines simultaneously [1]. Design of the tuner has been changed to deliver roughly 3 times larger frequency tuning range. Working requirements for off-frequency operation (OFO) state that cavities be tuned at least twice a month. This specification requires the in-crease of the tuner longevity by 20 times compared with LCLS-II demands. Accelerated longevity tests of the LCLS-II HE dressed cavity with tuner were conducted at FNAL's HTS. Detail analysis of wearing and impacts on performances of the tuner's piezo and stepper motor actuators will be presented. Additionally, results of longevity testing of the dressed cavity bellow, when cooled down to 2 K and compressed by 2.6 mm for roughly 2000 cycles, will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2.6GHz SRF Cavity Tuner for DarkPhoton Experiment [Poster]

There are several experiments ongoing at FNAL that require frequency tuning of bare (undressed) SRF cavities when they are cooled down and operated inside dilution refrigerator. One of these experiments is for the search of dark photons using a 2.6 GHz SRF cavity. The limited heat capacity of a dilution refrigerator prevents using a stepper motor for an SRF cavity tuner. The tuner for the 2.6 GHz SRF cavity will be equipped with encapsulated piezo actuators that will deliver long and short-range frequency tuning. Design of the tuner and results of the testing cavity/tuner system at ambient environment and at T = 77 K will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗