Search NASA⌕ Search

Engineering topics

Zahia Djouadi

Publications and source records attributed to Zahia Djouadi.

Reflectance spectra measurement plan of captured samples from Ryugu: current status

Hayabusa2 spacecraft is equipped with Optical Navigation Camera (ONC) andNear-infrared Spectrometer (NIRS3), and has obtained reflectance spectra of the C-type near-Earth asteroid Ryugu over a wavelength range of 0.40–0.95 μm and 1.8–3.2 μm, respectively. It was revealed that Ryugu exhibits globally very low albedo (less than 0.02 at 0.55 and 2.0 μm), a slightly positive spectral slope, and an ubiquitous weak but sharp OH absorption band centered at 2.72 μm,showing a little regional heterogeneities. Thus, the surface material of Ryugu can be estimated as relatively similar to moderately heated carbonaceous chondrites, e.g., moderately dehydrated CI and CM, and enriched in carbon (Kitazato et al., 2019; Sugita et al., 2019; Tatsumi et al., 2020).Hayabusa2 successfully has performed twice touch down operations, and the captured sample will be brought back to the Earth in late 2020 (Morota et al., 2020; Tachibana et al., in preparation). To clarify Ryugu’s mineralogical and physicochemical properties and their varieties, effective for spectral characteristics obtained by ONC and NIRS3, several grains are planned to be distributed to several primary analysis groups. In this study, we report the current status of our spectral analysis plan in Hayabusa2 MINeralogy and PETrology of coarse grains (MIN-PET CG) team led by T. Nakamura, and the latest rehearsal analysis result using carbonaceous chondrite samples. MIN-PET CG rehearsal measurements have been performed to obtain detailed spectral properties of Ryugu grains with diverse spatial resolutions ranging from μm to mm scale or larger; using a few mm size polished CM sample with several microscopic imaging spectrometers covering various spatial range; with 200 μmor finer spatial resolution at Institut d’Astrophysique Spatiale, ~50 and 150 μm spatial resolution invisible and IR ranges at Brown University, and with 40 μm or larger spatial resolution at Tohoku University, and using mm-size CM and CI grains with a diffuse reflectance spectrometer with a few mm resolution at Tohoku University. Diffuse reflectance spectroscopy measurements undergo to use several mm-size CM or CI chondrite grains with Bruker VERTEX 70v, which covers ~0.38–15 μm in wavelength. To keep returned samples out of atmosphere avoiding any terrestrial contamination, wehave prepared an air shutoff cell to put samples and standard materials together kept in a N2 purged condition (Amano et al., 2020). Samples are Murchison CM chondrite showing typically ~5%reflectance with a strong OH absorption band at ~2.8 μm, and laboratory heated CI chondrite showing~3% reflectance, and a weak OH absorption band at ~2.7 μm. We will perform (1) fixed angle condition as laboratory standard setting at incident, emission, and phase angles of 30°, 0°, 30°, or 0°,30°, 30°, and (2) various angle conditions for photometric corrections. Future lab analyses of samples returned from Ryugu will provide direct and detailed information on the mineralogical and physicochemical properties of Ryugu, and relationship of spectral characteristics obtained by remote sensing and laboratory instruments.

M. Matsuoka↗

Initial analysis of “stone” size Ryugu samples: current status

As a part of the initial analysis of the Ryugu samples, we perform a variety of analyses of millimeter-sized "stones". Our goals are to elucidate the entire formation process of C-type asteroid Ryugu from the viewpoint of petrology and mineralogy ande obtain necessary information by sample analysis, and then simulate the formation of Ryugu based on the evidencef obtained rom sample analysis. Eighteen stones (8 from Room A and 10 from Room C) were received from the ISAS curation facility on June 1, 2021, and brought into a fully nitrogen-displaced glove box at Tohoku University. At the same time, we also received the powder samples from Room A and Room C. To completely block the atmosphere from leaking into the container, all samples were put in the sample transport containers prepared by ISAS, transferred from the main chamber to the glovebox at ISAS, and then all containers were completely sealed in plastic bags with moisture and oxygen absorbers. No moisture or oxygen was detected when the bags were opened in the glove box at Tohoku University, so it was confirmed that there was no exposure to the atmosphere during transport. To date, a number of analyses have been carried out successfully and almost on schedule. The analysis started with the measurement of reflectance spectra, which are sensitive to atmospheric oxidation, hydroxylation, and adsorbed water. The visible, near-infrared, and mid-infrared reflectance spectra were measured while the samples were kept airtight. The spectra of powder samples and stone samples (as aggregates and as single stone) were successfully obtained. A major feature of the stone team's analysis is the use of synchrotron radiation facilities around the world. Since this analysis is non-destructive, stone samples whose reflectance spectra were measured were sent to KEK, SPring-8, ESRF (France), SOLEIL (France), DESY (Germany), and APS (USA). Using these synchrotron radiation facilities, high spatial resolution and sensitivity XRD, STXM, XANES, CT [1], IR-CT, FT-IR [2, 3], XRF, and Mössbauer analyses were performed. Most of the analyses were carried out under air-tight conditions on the stone samples and the particulates separated from the stone samples. These analyses allowed us to determine the three-dimensional distribution of minerals and elements, redox state, density and porosity of the stone samples. Furthermore, as a characteristic analysis of the stone team, light elemental analysis using negative Muon was performed at the MLF facility of J-PARC with an exceptionally long allocation of machine time. This is the only non-destructive method to measure the concentration of light elements in the whole (not the surface) of stone samples. Because the characteristic X-rays produced by muon irradiation are much higher in energy than the fluorescent X-rays produced by X-ray irradiation, there is little effect of self-absorption by the sample, and therefore, the concentration of light elements such as carbon, oxygen, and Na in the entire "stone" sample can be determined. Some stone samples are currently being measured for heat and strength physical properties in order to understand the physical properties of asteroid Ryugu. The data obtained from these measurements are useful for interpreting the remote-sensing data data taken from the surface layer of the asteroid Ryugu [4-7]. It is also important for understanding the behavior of the Ryugu material during impact events. The surfaces of many stone samples were observed by electron microscopy and other techniques, especially on natural “flat” surfaces formed on 5 stomes. As a result, characteristric mineral aggregates formed by the reactions with water and characteiristic impact features were observed on some of the samples. Based on the observations of surfaces and the synchrotron measurements of the whole stones, important objects such as characteristic structures and specific crystal aggregates for understanding the formation history of the asteroid were identified, and these parts were separated from the stone samples using an Xe beam (pFIB) and analyzed by various methods including transmission electron microscopy and synchrotron radiation analysis. Many stone samples, from which important objects have been separated, are embedded in epoxy resin and cut to produce many polished sections. Electron microscopy and spectroscopic measurements of the polished surfaces are being carried out to reveal the detailed mineralogical properties and elemental distribution inside the stone samples. In the fall, machine time for synchrotron radiation will begin, and we plan to analyze single crystals and characteristic objects separated from the stone samples.

Tomoki Nakamura↗