Simulations of multi-contrast x-ray imaging using near-field speckles

X-ray dark-field and phase-contrast imaging using near-field speckles is a novel technique that overcomes limitations inherent in conventional absorption x-ray imaging, i.e. poor contrast for features with similar density. Speckle-based imaging yields a wealth of information with a simple setup tolerant to polychromatic and divergent beams, and simple data acquisition and analysis procedures. Here, we present a simulation software used to model the image formation with the speckle-based technique, and we compare simulated results on a phantom sample with experimental synchrotron data. Thorough simulation of a speckle-based imaging experiment will help for better understanding and optimising the technique itself.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of x-ray speckle-based dark-field and phase-contrast imaging with a polychromatic beam

Following the first experimental demonstration of x-ray speckle-based multimodal imaging using a polychromatic beam [I. Zanette et al., Phys. Rev. Lett. 112(25), 253903 (2014)], we present a simulation study on the effects of a polychromatic x-ray spectrum on the performance of this technique. We observe that the contrast of the near-field speckles is only mildly influenced by the bandwidth of the energy spectrum. Moreover, using a homogeneous object with simple geometry, we characterize the beam hardening artifacts in the reconstructed transmission and refraction angle images, and we describe how the beam hardening also affects the dark-field signal provided by speckle tracking. This study is particularly important for further implementations and developments of coherent speckle-based techniques at laboratory x-ray sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-contrast 3D X-ray imaging of porous and composite materials

Grating-based X-ray computed tomography allows for simultaneous and nondestructive determination of the full X-ray complex index of refraction and the scattering coefficient distribution inside an object in three dimensions. Its multi-contrast capabilities combined with a high resolution of a few micrometers make it a suitable tool for assessing multiple phases inside porous and composite materials such as concrete. Here, we present quantitative results of a proof-of-principle experiment performed on a concrete sample. Thanks to the complementarity of the contrast channels, more concrete phases could be distinguished than in conventional attenuation-based imaging. The phase-contrast reconstruction shows high contrast between the hardened cement paste and the aggregates and thus allows easy 3D segmentation. Thanks to the dark-field image, micro-cracks inside the coarse aggregates are visible. We believe that these results are extremely interesting in the field of porous and composite materials studies because of unique information provided by grating interferometry in a non-destructive way.

36 MATERIALS SCIENCE↗

Design aspects of X-ray grating interferometry

Considerations are made for the design of X-ray grating interferometers in general and, in particular, for the case of a parallel beam with a high degree of spatial coherence. We specifically discuss the properties of different types of gratings and the interdependence of instrument parameters and performance characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

At-wavelength characterization of refractive x-ray lenses using a two-dimensional grating interferometer

We report on the application of a two-dimensional hard x-ray grating interferometer to x-ray optics metrology. The interferometer is sensitive to refraction angles in two perpendicular directions with a precision of 10 nrad. It is used to observe the wavefront changes induced by a single parabolic beryllium focusing lens of large radius of curvature. The lens shape is reconstructed and its residual aberrations are analyzed. Its profile differs from an ideal parabolic shape by less than 2 {mu}m or {lambda}/50 at {lambda} = 0.54 A wavelength.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structured scintillator for hard x-ray grating interferometry

Grating interferometry at conventional x-ray tubes improves the quality of radiographies and tomograms by providing phase and scattering contrast data. The main challenge encountered when applying this technique at high photon energies, as required by many applications to obtain sufficient penetration depth, is to maintain a high fringe visibility. In this letter, we report on a substantial improvement in fringe visibility and according improvements in image quality achieved by replacing the absorbing analyzer grating of the interferometer with a structured scintillator grating. This development represents a significant step toward the implementation of this technique in industrial testing and medical applications.