TDR Using Autocorrelation and Varying-Duration Pulses

In an alternative to a prior technique of time-domain-reflectometry (TDR) in which very short excitation pulses are used, the pulses have very short rise and fall times and the pulse duration is varied continuously between a minimum and a maximum value. In both the present and prior techniques, the basic idea is to (1) measure the times between the generation of excitation pulses and the reception of reflections of the pulses as indications of the locations of one or more defects along a cable and (2) measure the amplitudes of the reflections as indication of the magnitudes of the defects. In general, an excitation pulse has a duration T. Each leading and trailing edge of an excitation pulse generates a reflection from a defect, so that a unique pair of reflections is associated with each defect. In the present alternative technique, the processing of the measured reflection signal includes computation of the autocorrelation function R(tau) identical with fx(t)x(t-tau)dt where t is time, x(t) is the measured reflection signal at time t, and taus is the correlation interval. The integration is performed over a measurement time interval short enough to enable identification and location of a defect within the corresponding spatial interval along the cable. Typically, where there is a defect, R(tau) exhibits a negative peak having maximum magnitude for tau in the vicinity of T. This peak can be used as a means of identifying a leading-edge/trailing-edge reflection pair. For a given spatial interval, measurements are made and R(tau) computed, as described above, for pulse durations T ranging from the minimum to the maximum value. The advantage of doing this is that the effective signal-to-noise ratio may be significantly increased over that attainable by use of a fixed pulse duration T.

Lucena, Angel↗

Instrumentation System Diagnoses a Thermocouple

An improved self-validating thermocouple (SVT) instrumentation system not only acquires readings from a thermocouple but is also capable of detecting deterioration and a variety of discrete faults in the thermocouple and its lead wires. Prime examples of detectable discrete faults and deterioration include open- and short-circuit conditions and debonding of the thermocouple junction from the object, the temperature of which one seeks to measure. Debonding is the most common cause of errors in thermocouple measurements, but most prior SVT instrumentation systems have not been capable of detecting debonding. The improved SVT instrumentation system includes power circuitry, a cold-junction compensator, signal-conditioning circuitry, pulse-width-modulation (PWM) thermocouple-excitation circuitry, an analog-to-digital converter (ADC), a digital data processor, and a universal serial bus (USB) interface. The system can operate in any of the following three modes: temperature measurement, thermocouple validation, and bonding/debonding detection. The software running in the processor includes components that implement statistical algorithms to evaluate the state of the thermocouple and the instrumentation system. When the power is first turned on, the user can elect to start a diagnosis/ monitoring sequence, in which the PWM is used to estimate the characteristic times corresponding to the correct configuration. The user also has the option of using previous diagnostic values, which are stored in an electrically erasable, programmable read-only memory so that they are available every time the power is turned on.

Perotti, Jose↗