Search NASA⌕ Search

Engineering topics

Zeck, B. A.

Publications and source records attributed to Zeck, B. A..

Improved limits on Fierz interference using asymmetry measurements from the Ultracold Neutron Asymmetry (UCNA) experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the β-decay asymmetry parameter, A 0 , for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their β-decay electrons are detected with ≈4π acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to b n , the Fierz interference term in the neutron β-decay rate. In this work, we determine bn from the energy dependence of A 0 using the data taken during the UCNA 2011–2013 run. In addition, we present the same type of analysis using the earlier 2010 A dataset. Furthermore, motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new b n measurement using the weighted average of our asymmetry dataset fits, to obtain b n = 0.066 ± 0.041 stat ± 0.024 syst which corresponds to a limit of -0.012 < b n < 0.144 at the 90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$\alpha$0$\gamma$)$^7$Li (6%) and $^{10}$B(n,$\alpha$1$\gamma$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $\alpha$, $^7$Li and $\gamma$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Nab to determine correlations in unpolarized neutron decay

The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants λ = gA/gV with precision δλ/λ ~3 × 10 -4 and search for a Fierz term b F at a level Δb F < 10 -3 . The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton’s time of flight and the decay electron’s energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. Here, to explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of Δb F < 10 -2 in the beta decay of 45 Ca using the UCNA spectrometer.

Beta spectrum↗

Search for dark matter decay of the free neutron from the UCNA experiment: n → χ + e + e –

It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle (χ) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single χ along with an e + e – pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with ~4π acceptance using a pair of detectors that observe a volume of stored ultracold neutrons. The summed kinetic energy (E e + e – ) from such events is used to set limits, as a function of the χ mass, on the branching fraction for this decay channel. For χ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at >>5σ level for 100 < E e + e – < 644keV. In conclusion, if the χ+e + e – final state is not the only one, we set limits on its branching fraction of <10 –4 for the above E e + e – range at >90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New result for the neutron β -asymmetry parameter A 0 from UCNA

Background: The neutron β-decay asymmetry parameter A 0 defines the angular correlation between the spin of the neutron and the momentum of the emitted electron. Values for A 0 permit an extraction of the ratio of the weak axial-vector to vector coupling constants, λ≡g A /g V , which under assumption of the conserved vector current hypothesis (g V =1) determines g A . Precise values for g A are important as a benchmark for lattice QCD calculations and as a test of the standard model. Purpose: The UCNA experiment, carried out at the Ultracold Neutron (UCN) source at the Los Alamos Neutron Science Center, was the first measurement of any neutron β-decay angular correlation performed with UCN. This article reports the most precise result for A 0 obtained to date from the UCNA experiment, as a result of higher statistics and reduced key systematic uncertainties, including from the neutron polarization and the characterization of the electron detector response. Methods: UCN produced via the downscattering of moderated spallation neutrons in a solid deuterium crystal were polarized via transport through a 7 T polarizing magnet and a spin flipper, which permitted selection of either spin state. The UCN were then contained within a 3-m long cylindrical decay volume, situated along the central axis of a superconducting 1 T solenoidal spectrometer. With the neutron spins then oriented parallel or anti-parallel to the solenoidal field, an asymmetry in the numbers of emitted decay electrons detected in two electron detector packages located on both ends of the spectrometer permitted an extraction of A 0 . Results: The UCNA experiment reports a new 0.67% precision result for A 0 of A 0 = -0.12054(44) stat (68) syst , which yields λ=g A /g V = -1.2783(22). Combination with the previous UCNA result and accounting for correlated systematic uncertainties produces A 0 = -0.12015(34) stat (63) syst and λ=g A /g V = -1.2772(20).Conclusions: This new result for A 0 and g A /g V from the UCNA experiment has provided confirmation of the shift in values for g A /g V that has emerged in the published results from more recent experiments, which are in striking disagreement with the results from older experiments. Individual systematic corrections to the asymmetries in older experiments (published prior to 2002) were >10%, whereas those in the more recent ones (published after 2002) have been of the scale of <2%. Finally, the impact of these older results on the global average will be minimized should future measurements of A 0 reach the 0.1% level of precision with central values near the most recent results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First direct constraints on Fierz interference in free-neutron β decay

Precision measurements of free-neutron β decay have been used to precisely constrain our understanding of the weak interaction. However, the neutron Fierz interference term b n , which is particularly sensitive to beyond-standard-model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding b n =0.067±0.005 stat $+0.090\atop{-0.061}$ sys , consistent with the standard model. Lastly, the uncertainty is dominated by absolute energy reconstruction and the linearity of the β spectrometer energy response.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of commercial nickel-phosphorus coating for ultracold neutron guides using a pinhole bottling method

We report on the evaluation of commercial electroless nickel phosphorus (NiP) coatings for ultracold neutron (UCN) transport and storage. The material potential of 50μm thick NiP coatings on stainless steel and aluminum substrates was measured to be V F =213(5.2)neV using the time-of-flight spectrometer ASTERIX at the Lujan Center. The loss per bounce probability was measured in pinhole bottling experiments carried out at ultracold neutron sources at Los Alamos Neutron Science Center and the Institut Laue-Langevin. For these tests a new guide coupling design was used to minimize gaps between the guide sections. The observed UCN loss in the bottle was interpreted in terms of an energy independent effective loss per bounce, which is the appropriate model when gaps in the system and upscattering are the dominate loss mechanisms, yielding a loss per bounce of 1.3(1)×10 –4 . In conclusion, we also present a detailed discussion of the pinhole bottling methodology and an energy dependent analysis of the experimental results.

36 MATERIALS SCIENCE↗

Neutron decay correlations in the Nab experiment

The Nab experiment will measure the correlation a between the momenta of the beta particle and antineutrino in neutron decay as well as the Fierz term b which distorts the beta spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radial distribution of charged particles in a magnetic field

The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle’s helical trajectory, an analytic solution for the radial probability distribution function follows which applies to experiments in which particles are generated throughout a volume that spans a sufficient length along the axis of a homogeneous magnetic field. This approach leads to the same result as a different derivation given by Dubbers et al., Nucl. Instrum. Methods Phys. Res., Sect. A 763, 112–119 (2014). But the constant phase approximation does not strictly apply to finite source volumes or fixed positions, which lead to local maxima in the radial distribution of emitted particles at the plane of the detector. A simple method is given to calculate such distributions, then the effect is demonstrated with data from a {sup 207}Bi electron-conversion source in the superconducting solenoid magnet spectrometer of the Ultracold Neutron facility at the Los Alamos Neutron Science Center. Implications for neutron beta decay spectroscopy are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗