The Effect of Radiation Damage on the Charge Collection Efficiency of Silicon Avalanche Photodiodes

Understanding radiation effects on avalanche photodiodes (APDs) is important because they are used in several applications involving harsh radiation environments. APDs are used as photosensors in applications where speed and detection efficiency are critical. Proton irradiation experiments on a commercial off-the-shelf APD demonstrated that the irradiation flux and applied reverse bias have a strong influence on the severity of radiation effects. This is measured using the ion beam induced charge (IBIC) technique in which charge collection efficiency (CCE) describes the signal response from a device. CCE can degrade substantially due to radiation damage, but recent measurements show that certain combinations of irradiation flux and reverse bias can lead to increases in CCE up to 186% ± 24% for irradiations with 2 MeV protons at a fluence of 6.4 × 10 11 cm –2 . This defect-enhanced charge multiplication (DECM) only appeared when the reverse bias during irradiation ranged from 170 to 1830 V out of a maximum operating bias of 2000 V and the proton flux ranged from 9.8 × 10 7 to 3.4 × 10 9 cm –2 s –1 . Furthermore values outside of either range led to losses in CCE. It is expected that DECM should be encountered in other devices, especially those with sufficiently high electric fields to cause impact ionization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bias-dependent displacement damage effects in a silicon avalanche photodiode

Radiation effects studies on a commercial beveled-edge avalanche photodiode (APD) showed that applying reverse bias to the device during irradiation enhanced the severity of apparent damage. Proton microbeam irradiations were made using a proton beam energy of 2 MeV and fluence ranging from 2.0 × 10 10 to 5.1 × 10 12 cm -2 . Charge collection measurements using the ion beam induced charge (IBIC) technique showed that relative losses increased by up to an order of magnitude when the reverse bias applied during irradiation increased from 50 to 1500 V. The presence of reverse bias also led to equivalent losses in charge collection that would only be seen in irradiations with an order of magnitude higher fluence in unbiased APDs. The results demonstrate that bias-enhanced irradiation damage is insufficiently understood and must be accounted for in characterizations of radiation effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗