Transient Pressure Interference During CO2 Injection in Saline Aquifers
Abstract CO2 injection in subsurface geological formations (e.g. deep saline aquifers) causes pressure perturbations over a large area surrounding the injection well. Observation wells are widely considered in geologic CO2 storage (GCS) projects where the pressure perturbation induced by CO2 injection is measured. In this work, we use analytical and numerical modeling tools along with field data to examine the pressure behavior in GCS projects before and after CO2 arrival at an observation well. Prior to CO2 arrival, a baseline pressure trend is established which corresponds to single-phase brine flow across the observation well (approximated by Theis solution). Therefore, analysis of early-time pressure data is straightforward, provides the single-phase flow characteristics (mobility and storativity), and helps establishing a baseline pressure change that can be extended beyond the single-phase flow period at the observation well. Upon CO2 arrival, a departure from this baseline trend is expected. For the pressure to detect the CO2 arrival at an observation well, the departure from baseline pressure behavior must be significant and well above the background noise levels. We use existing analytical models to determine the strength of the expected pressure departure signal from the baseline trend upon CO2 arrival. The strength of the expected pressure departure is found to be directly proportional to the mobility ratio. Accordingly, we establish a criterion to determine whether the pressure at an observation well can detect the CO2 arrival. We present an analysis approach through application to synthetic and field data and show the characteristic pressure behavior before and after CO2 arrival. We show that while generally the pressure can be either above or below the expected baseline pressure trend, it would be likely above the baseline upon CO2 arrival. This is because the mobility ratio becomes less than unity after CO2 arrival. We show that depending on the reservoir characteristics, changes in the pressure trend may or may not be sufficient to detect the CO2 arrival.
GCS site selection in saline Miocene formations in South Louisiana
One of the key requirements of a commercial scale geologic carbon sequestration (GCS) site selection process is identifying injection sites to safely inject and retain injected CO 2 over extended time scales. This requires thorough evaluation of site-specific surface and subsurface features. A site screening and selection framework was developed and used to identify potential sites in South Louisiana, incorporating surface data including site proximity to large CO 2 stationary sources, vicinity of large population centres and state lands, land usage, legacy oil and gas wells, and local/regional geologic trends. Regionally the Miocene sediments thicken and dip towards the south, reflecting a prograding deltaic environment during the Miocene which resulted in the deposition of thick packages of fine-grained sandstones suitable for CO 2 storage. The results of three example selected sites that are spatially separated with varying subsurface and surface features are presented in this study. The multiple stacked sand zones at these sites provide ample amount of pore volume for CO 2 storage with varying degree of stratigraphic/structural traps for long terms storage containment. Here, the screening framework presented in this study and the detailed evaluation of three specific sites in South Louisiana provides a process to screen and characterize sites for GCS projects and the suitability of these Miocene sediments for commercial scale CO 2 storage projects. It is envisioned that the analysis described in this paper will be beneficial for a large number of audiences involved in GCS work and aid in the site selection process.
Heat pulse testing at monitoring wells to estimate subsurface fluid velocities in geological CO 2 storage
Monitoring the injected CO 2 during geological CO 2 storage (GCS) is essential to assure containment and identify CO 2 leakage. Here in this work, a new approach is introduced to estimate the evolution of the downhole fluid velocity at a monitoring well and identify CO 2 arrival time using in-well heat pulse/tracer test. The proposed technique involves using a downhole heater to generate a series of heat pulses and measuring their corresponding temperature response. The surface temperature of the downhole heater is controlled by the supplied electrical power and the heat loss by convection to the surroundings. Convective heat transfer is well described using Newton's law of cooling in which the temperature difference between the heater and the surrounding fluids drives the heat transfer, for which the convection heat transfer coefficient (h) controls the magnitude of heat loss. Among various factors that control h, it depends on the type of the flowing fluid and its velocity. Through analyzing the measured temperature at different heat pulses, the changes in h - due to mobilization of the in-situ brine or CO 2 arrival - can be estimated. Consequently, the velocity of the flowing fluid across the heater can be obtained. Since heat transfer by convection is sensitive to the type of the surrounding fluid, intrusion of CO 2 can be detected from the relatively higher surface temperature obtained at CO 2 arrival. Churchill and Bernstein (1977)'s correlation is adopted to estimate the change of fluid velocity in terms of the change in h. To demonstrate the validity of the proposed technique, the results are applied and validated against those of COMSOL Multiphysics simulation tool for single-phase brine (before CO 2 arrival) and single-phase CO 2 (after CO 2 arrival). The observed temperature heating is sensitive to the flowing fluid velocity and fluid type. The temperature signal observed at CO 2 arrival is large and easily detectable using temperature monitoring tool which provides reliable indication for tracking CO 2 arrival at monitoring wells compared with passive temperature monitoring. The results obtained using the proposed technique agree very well with the numerical results obtained from the simulation tool with a maximum estimation error of 7 percent.
CO 2 zonal injection rate allocation and plume extent evaluation through wellbore temperature analysis
Temperature analysis during a pause in injection operations, known as warmback analysis, has been used in the petroleum industry for evaluating the injection conformance and estimating the location of the flooded front in applications, such as waterflooding oil reservoirs. Here in this work, methods are introduced to extend the application of temperature warmback analysis to estimate the zonal CO 2 injection rate and zonal CO 2 plume extent during geologic CO 2 storage in a saline aquifer. First, novel analytical solutions are developed to model transient temperature in the aquifer during the injection and subsequent shut-in periods considering two-phase flow (gaseous CO 2 and aqueous brine) conditions in the aquifer. The solution involves a discretization of the aquifer into regions; the energy and mass conservation equations for the regions are solved simultaneously considering appropriate boundary conditions at the interfaces. Two solutions techniques are presented: multi-region and three-region solutions. Inverse models are developed accordingly to evaluate the injection profile and estimate the extent of the plume front in the reservoir during the injection period. The multi-region solution results in an inversion approach that requires regression analysis. However, the three-region formulation results in a simple graphical technique for inverse modeling. The analytical solutions are validated against a thermally coupled reservoir simulation tool using different synthetic cases for CO 2 injection in deep saline aquifers. The results of the developed solutions provide a good match with numerical results during forward and inverse modeling.
Injection data analysis using material balance time for CO 2 storage capacity estimation in deep closed saline aquifers
Estimating the ultimate storage capacity of deep saline aquifers is important to address the formation potential to store the envisioned large volumes of CO 2 . Injection data (i.e. injection rate, bottomhole pressure, and cumulative injected volume of CO 2 ) are routinely recorded during storage operations. These data contain valuable information on the subsurface (e.g. the reservoir pore volume and the formation storage capacity) that can be extracted. In this paper, we present a two-step graphical technique to infer the pore volume and the ultimate storage capacity of closed saline aquifers by analyzing the available injection data. First, the pore volume is inferred through adapting the concept of the material balance time. Material balance time is an approximate superposition time function developed to interpret production data from oil and gas wells operating at variable pressure/rate conditions during the boundary-dominated flow period. Using material balance techniques, the ultimate storage capacity is then estimated through linear extrapolation of the average pressure trend to the maximum allowable pressure the formation can withstand. The average pressure is not available in practice, but is can be obtained from the injection data. Two approaches are presented in this study to calculate the average pressure; namely the rigorous and the approximate approaches. Unlike the rigorous approach, the approximate approach does not require a prior knowledge of some reservoir properties (e.g. relative permeability, absolute permeability, formation porosity and thickness) to calculate the average pressure. To investigate its potential and reliability in analyzing CO 2 injection data, the proposed technique is applied to four synthetic cases representing different well operating conditions. Results indicate that the approximate approach consistently overestimates the actual (simulated) storage capacity as compared to the rigorous approach. The agreement - between the inferred and the simulated reservoir pore volume, and between the analytical and numerical estimates of storage capacity - validates the potential application of the technique to CO 2 storage in closed saline aquifers. The technique is further substantiated through application to a field data set utilized from a commercial-scale geological storage (CGS) project. Finally, field data interpretation shows that the proposed technique can be utilized to identify the degree of hydraulic continuity and reservoir compartmentalization within a target formation by interpreting the corresponding pressure and rate responses.
Effects of injection well operation conditions on CO 2 storage capacity in deep saline aquifers
Not provided.
Pressure Transient Analysis to Determine Anisotropic Fault Leakage Characteristics
Not provided.
Pressure falloff testing to characterize CO 2 plume and dry-out zone during CO 2 injection in saline aquifers
The fluid mobilities and the lateral extent of the CO 2 plume and the dry-out zone are among important unknowns required to effectively manage CO 2 storage in saline aquifers projects. These unknowns can be derived from pressure falloff testing which has been widely used to characterize the subsurface. This paper provides a three-region analytical solution for falloff pressure during the infinite-acting period of CO 2 injection in saline aquifers. The solution is derived using Laplace transformation technique of the governing diffusivity equations and the accompanying initial and boundary conditions. The exact solution is validated against numerical results obtained from a black-oil reservoir simulator for two cases. The solution is approximated into simple forms in real-time domain considering different time periods. Then, a graphical semi-log analysis technique based on the approximate solutions is provided as an interpretation tool of falloff tests where the fluid mobilities and the extents of dry-out zone and CO 2 plume can be inferred. The interpretation technique is applied to synthetic falloff test data to investigate its potential and reliability.