Search NASA⌕ Search

Engineering topics

Zeng, Dong

Publications and source records attributed to Zeng, Dong.

A melting-like process and the local structures during the anatase-to-rutile transition

Highlights: • The maximum size of anatase crystallites is more useful to describe the phase stability than the traditional critical size. • The melting-like process accelerates the phase transition from anatase to rutile. • The cis-coordinated anatase is transformed to trans-coordinated rutile by torsion & rotation of TiO{sub 6} octahedra in anatase. Phase transition of titanium oxide from anatase to rutile was investigated by using transmitted electron microscope (TEM), scanning electron microscope (SEM) and X-ray diffraction (XRD), in combination with the atomic pair distribution function (PDF) technique. The transition range is about 528–805 °C and the critical size is ~73 nm for the sol-gel samples calcined for 6 h. A melting-like process was evidently observed in the transition samples by SEM and it will speed up the phase transition. PDF reveals that anatase crystallites are packed by neighbouring TiO{sub 6} octahedra in a cis-coordinated way. Anatase crystallites larger than the critical size will be unstable and transform into rutile in a trans-coordinated way by torsion and rotation of part of octahedra and it will rapidly spread the entire crystallites driven by a melting-like process. We suggest the maximum size of anatase will be more technically useful for the description of the phase stability from anatase to rutile because unstable small anatase crystals are consumed during longer calcination process to grow the larger anatase crystals.

36 MATERIALS SCIENCE↗

Cerebral perfusion computed tomography deconvolution via structure tensor total variation regularization

Purpose: Cerebral perfusion computed tomography (PCT) imaging as an accurate and fast acute ischemic stroke examination has been widely used in clinic. Meanwhile, a major drawback of PCT imaging is the high radiation dose due to its dynamic scan protocol. The purpose of this work is to develop a robust perfusion deconvolution approach via structure tensor total variation (STV) regularization (PD-STV) for estimating an accurate residue function in PCT imaging with the low-milliampere-seconds (low-mAs) data acquisition. Methods: Besides modeling the spatio-temporal structure information of PCT data, the STV regularization of the present PD-STV approach can utilize the higher order derivatives of the residue function to enhance denoising performance. To minimize the objective function, the authors propose an effective iterative algorithm with a shrinkage/thresholding scheme. A simulation study on a digital brain perfusion phantom and a clinical study on an old infarction patient were conducted to validate and evaluate the performance of the present PD-STV approach. Results: In the digital phantom study, visual inspection and quantitative metrics (i.e., the normalized mean square error, the peak signal-to-noise ratio, and the universal quality index) assessments demonstrated that the PD-STV approach outperformed other existing approaches in terms of the performance of noise-induced artifacts reduction and accurate perfusion hemodynamic maps (PHM) estimation. In the patient data study, the present PD-STV approach could yield accurate PHM estimation with several noticeable gains over other existing approaches in terms of visual inspection and correlation analysis. Conclusions: This study demonstrated the feasibility and efficacy of the present PD-STV approach in utilizing STV regularization to improve the accuracy of residue function estimation of cerebral PCT imaging in the case of low-mAs.

60 APPLIED LIFE SCIENCES↗