Search NASA⌕ Search

Engineering topics

Zeng, Rongping

Publications and source records attributed to Zeng, Rongping.

Report on the AAPM grand challenge on deep generative modeling for learning medical image statistics

Abstract Background The findings of the 2023 AAPM Grand Challenge on Deep Generative Modeling for Learning Medical Image Statistics are reported in this Special Report. Purpose The goal of this challenge was to promote the development of deep generative models for medical imaging and to emphasize the need for their domain‐relevant assessments via the analysis of relevant image statistics. Methods As part of this Grand Challenge, a common training dataset and an evaluation procedure was developed for benchmarking deep generative models for medical image synthesis. To create the training dataset, an established 3D virtual breast phantom was adapted. The resulting dataset comprised about 108 000 images of size 512 512. For the evaluation of submissions to the Challenge, an ensemble of 10 000 DGM‐generated images from each submission was employed. The evaluation procedure consisted of two stages. In the first stage, a preliminary check for memorization and image quality (via the Fréchet Inception Distance [FID]) was performed. Submissions that passed the first stage were then evaluated for the reproducibility of image statistics corresponding to several feature families including texture, morphology, image moments, fractal statistics, and skeleton statistics. A summary measure in this feature space was employed to rank the submissions. Additional analyses of submissions was performed to assess DGM performance specific to individual feature families, the four classes in the training data, and also to identify various artifacts. Results Fifty‐eight submissions from 12 unique users were received for this Challenge. Out of these 12 submissions, 9 submissions passed the first stage of evaluation and were eligible for ranking. The top‐ranked submission employed a conditional latent diffusion model, whereas the joint runners‐up employed a generative adversarial network, followed by another network for image superresolution. In general, we observed that the overall ranking of the top 9 submissions according to our evaluation method (i) did not match the FID‐based ranking, and (ii) differed with respect to individual feature families. Another important finding from our additional analyses was that different DGMs demonstrated similar kinds of artifacts. Conclusions This Grand Challenge highlighted the need for domain‐specific evaluation to further DGM design as well as deployment. It also demonstrated that the specification of a DGM may differ depending on its intended use.

Radiology, Nuclear Medicine & Medical Imaging↗

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

Estimating local noise power spectrum from a few FBP-reconstructed CT scans

Purpose: Traditional ways to estimate 2D CT noise power spectrum (NPS) involve an ensemble average of the power spectrums of many noisy scans. When only a few scans are available, regions of interest are often extracted from different locations to obtain sufficient samples to estimate the NPS. Using image samples from different locations ignores the nonstationarity of CT noise and thus cannot accurately characterize its local properties. The purpose of this work is to develop a method to estimate local NPS using only a few fan-beam CT scans. Methods: As a result of FBP reconstruction, the CT NPS has the same radial profile shape for all projection angles, with the magnitude varying with the noise level in the raw data measurement. This allows a 2D CT NPS to be factored into products of a 1D angular and a 1D radial function in polar coordinates. The polar separability of CT NPS greatly reduces the data requirement for estimating the NPS. The authors use this property and derive a radial NPS estimation method: in brief, the radial profile shape is estimated from a traditional NPS based on image samples extracted at multiple locations. The amplitudes are estimated by fitting the traditional local NPS to the estimated radial profile shape. The estimated radial profile shape and amplitudes are then combined to form a final estimate of the local NPS. We evaluate the accuracy of the radial NPS method and compared it to traditional NPS methods in terms of normalized mean squared error (NMSE) and signal detectability index. Results: For both simulated and real CT data sets, the local NPS estimated with no more than six scans using the radial NPS method was very close to the reference NPS, according to the metrics of NMSE and detectability index. Even with only two scans, the radial NPS method was able to achieve a fairly good accuracy. Compared to those estimated using traditional NPS methods, the accuracy improvement was substantial when a few scans were available. Conclusions: The radial NPS method was shown to be accurate and efficient in estimating the local NPS of FBP-reconstructed 2D CT images. It presents strong advantages over traditional NPS methods when the number of scans is limited and can be extended to estimate the in-plane NPS of cone-beam CT and multislice helical CT scans.

61 RADIATION PROTECTION AND DOSIMETRY↗