Search NASA⌕ Search

Engineering topics

Zeng, X

Publications and source records attributed to Zeng, X.

SU-F-R-24: Identifying Prognostic Imaging Biomarkers in Early Stage Lung Cancer Using Radiomics

Purpose: Patients diagnosed with early stage lung cancer have favorable outcomes when treated with surgery or stereotactic radiotherapy. However, a significant proportion (∼20%) of patients will develop metastatic disease and eventually die of the disease. The purpose of this work is to identify quantitative imaging biomarkers from CT for predicting overall survival in early stage lung cancer. Methods: In this institutional review board-approved HIPPA-compliant retrospective study, we retrospectively analyzed the diagnostic CT scans of 110 patients with early stage lung cancer. Data from 70 patients were used for training/discovery purposes, while those of remaining 40 patients were used for independent validation. We extracted 191 radiomic features, including statistical, histogram, morphological, and texture features. Cox proportional hazard regression model, coupled with the least absolute shrinkage and selection operator (LASSO), was used to predict overall survival based on the radiomic features. Results: The optimal prognostic model included three image features from the Law’s feature and wavelet texture. In the discovery cohort, this model achieved a concordance index or CI=0.67, and it separated the low-risk from high-risk groups in predicting overall survival (hazard ratio=2.72, log-rank p=0.007). In the independent validation cohort, this radiomic signature achieved a CI=0.62, and significantly stratified the low-risk and high-risk groups in terms of overall survival (hazard ratio=2.20, log-rank p=0.042). Conclusion: We identified CT imaging characteristics associated with overall survival in early stage lung cancer. If prospectively validated, this could potentially help identify high-risk patients who might benefit from adjuvant systemic therapy.

60 APPLIED LIFE SCIENCES↗

Plasmon-enhanced reverse water gas shift reaction over oxide supported Au catalysts

We show that localized surface plasmon resonance (LSPR) can enhance the catalytic activities of different oxide-supported Au catalysts for the reverse water gas shift (RWGS) reaction. Oxide-supported Au catalysts showed 30 to 1300% higher activity for RWGS under visible light compared to dark conditions. Au/TiO2 catalyst prepared by the deposition-precipitation (DP) method with 3.5 nm average Au particle size showed the highest activity for the RWGS reaction. Visible light is converted into chemical energy for this reaction with up to a 5% overall efficiency. A shift in the apparent activation energy (from 47 kJ mol(-1) in dark to 35 kJ mol(-1) in light) and apparent reaction order with respect to CO2 (from 0.5 in dark to 1.0 in light) occurs due to the LSPR. Our kinetic results indicate that the LSPR increases the rate of either the hydroxyl hydrogenation or carboxyl decomposition more than any other steps in the reaction network.

Upadhye, AA↗

Synthesis and enhanced light absorption of alumina matrix nanocomposites containing multilayer oxide nanorods and silver nanoparticles

Highlights: {yields} Multilayer oxide nanorods (nanocables) were obtained via chemical processing. {yields} Ag nanoparticles were deposited between the core and shell layers of the nanorods. {yields} The structure and composition of the nanorods were analyzed by SEM and TEM. {yields} CoO nanorods and Ag nanoparticles enhance light absorption of the nanocomposites. -- Abstract: In this paper, multilayer oxide nanorods were deposited in the nanopores of anodic aluminum oxide (AAO) via solution infiltration followed by heat treatment. The nanorods have a core-shell structure. First, the shell (nanotube) with the thickness of about 40 nm was made of TiO{sub 2} through the hydrolysis of (NH{sub 4}){sub 2}TiF{sub 6}. Second, silver nanoparticles with the diameter of about 3 nm were added into the TiO{sub 2} layer through thermal decomposition of AgNO{sub 3} at elevated temperatures. Then, cylindrical cores (nanorods) of CoO and ZnO with 200 nm diameter were prepared, respectively. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to characterize the structure and composition of the nanorods. UV-vis light absorption measurements in the wavelength range from 350 to 1000 nm were performed to study the effect of nanorod and nanoparticle addition on the light absorption property of the alumina nanocomposites. It is found that CoO nanorods increase the light absorption of the alumina matrix composite in the wavelength range from 500 nm to 800 nm, but the TiO{sub 2} shell does not increase the light absorption much. The ZnO nanorods do not change the light absorption either. However, the addition of silver nanoparticles significantly enhances light absorption of both AAO/TiO{sub 2}/Ag/CoO and AAO/TiO{sub 2}/Ag/ZnO nanocomposites. This increase in the visible light absorption reveals that there exists surface plasmon around the fine silver nanoparticles in the nanorods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong aggregation and directional assembly of aromatic oligoamide macrocycles.

Aromatic oligoamide macrocycles exhibit strong preference for highly directional association. Aggregation happens in both nonpolar and polar solvents but is weakened as solvent polarity increases. The strong, directional assembly is rationalized by the cooperative action of dipole-dipole and {pi}-{pi} stacking interactions, leading to long nanotubular assemblies that are confirmed by SEM, TEM, AFM, and XRD. The persistent nanotubular assemblies contain non-collapsible hydrophilic internal pores that mediate highly efficient ion transport observed with these macrocycles and serve as cylindrical sites for accommodating guests such as metal ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Glass Monocapillary X-ray Optics And Their Applications In X-ray Microscopy

Elliptical, parabolic and Wolter type glass monocapillaries were fabricated for use as x-ray condensers in the energy range of 250 eV to 20 keV. On a routine basis a diameter error of +/-0.4 {mu}m and straightness error of 0.8 {mu}m (peak to valley) can be reached. The final test of condensers was performed at-wavelength by imaging the far field x-ray reflection intensity distribution using a laboratory microfocus x-ray source. For medium length condensers with a total length <80 mm, a total slope error of 40 murad rms was obtained. The applications in full-field x-ray microscopes and the future effort in developing capillary Wolter mirrors based on this technology are reported.

07 ISOTOPE AND RADIATION SOURCES↗

Toward Rapid Unattended X-ray Tomography of Large Planar Samples at 50-nm Resolution

X-ray tomography at sub-50 nm resolution of small areas ({approx}15 {mu}mx15 {mu}m) are routinely performed with both laboratory and synchrotron sources. Optics and detectors for laboratory systems have been optimized to approach the theoretical efficiency limit. Limited by the availability of relatively low-brightness laboratory X-ray sources, exposure times for 3-D data sets at 50 nm resolution are still many hours up to a full day. However, for bright synchrotron sources, the use of these optimized imaging systems results in extremely short exposure times, approaching live-camera speeds at the Advanced Photon Source at Argonne National Laboratory near Chicago in the US These speeds make it possible to acquire a full tomographic dataset at 50 nm resolution in less than a minute of true X-ray exposure time. However, limits in the control and positioning system lead to large overhead that results in typical exposure times of {approx}15 min currently.We present our work on the reduction and elimination of system overhead and toward complete automation of the data acquisition process. The enhancements underway are primarily to boost the scanning rate, sample positioning speed, and illumination homogeneity to performance levels necessary for unattended tomography of large areas (many mm{sup 2} in size). We present first results on this ongoing project.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A framework for chemical plant safety assessment under uncertainty.

We construct a framework for assessing the risk that the uncertainty in the plant feed and physical parameters may mask the loss of a reaction product. To model the plant, we use a nonlinear, quasi-steady-state model with stochastic input and parameters. We compute the probability that more than a certain product amount is diverted, given the statistics of the uncertainty in the plant feed, in the values of the chemical parameters, and in the output measurement. The uncertainty in the physical parameters is based on the one provided by the recently developed concept of thermochemical tables. We use Monte Carlo methods to compute the probabilities, based on a Cauchy-theorem-like approach to avoid making anything but the safest asymptotic assumptions, as well as to avoid the excessive noise in the region of low-probability events.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Resolution Spectroscopy of 16N_Lambda by Electroproduction

An experimental study of the 16O(e, e'K+)16N_Lambda reaction has been performed at Jefferson Lab. A thin film of falling water was used as a target. This permitted a simultaneous measurement of the p(e, e'K+)Lambda,Sigma_0 exclusive reactions and a precise calibration of the energy scale. A ground-state binding energy of 13.76 ± 0.16 MeV was obtained for 16N_Lambda with better precision than previous measurements on the mirror hypernucleus 16O_Lambda. Precise energies have been determined for peaks arising from a Lambda in s and p orbits coupled to the p1/2 and p3/2 hole states of the 15N core nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗