Search NASASearch

Engineering topics

Zent, Aaron

Publications and source records attributed to Zent, Aaron.

A Revised Calibration Function and Results for the Phoenix Mission TECP Relative Humidity Sensor

The original calibration function of the R(sub H) sensor on the Phoenix Thermal and Electrical Conductivity Sensor (TECP) has been revised in order to extend the range of the valid calibration, and to improve accuracy. The original function returned non-physical R(sub H) values at the lowest temperatures. To resolve this, and because the original calibration was performed against a pair of hygrometers that measured frost point (T(sub f)), the revised calibration equation is also cast in terms of frost point. Because of the complexity of maintaining very low temperatures and high R(sub H) in the laboratory, no calibration data exists at T is greater than 203K. However, sensor response during the mission was smooth and continuous down to 181 K. Therefore we have opted to include flight data in the calibration data set; selection was limited to data acquired during periods when the atmosphere is known to have been saturated. T(sub f) remained below 210 K throughout the mission(P is greater than 0.75 Pa). R(sub H), conversely, ranged from 1 to well under 0.01 diurnally, due to approximately 50 K temperature variations. To first order, both vapor pressure and its variance are greater during daylight hours. Variance in overnight humidity is almost entirely explained by temperature, while atmospheric turbulence contributes substantial variance to daytime humidity. Likewise, data gathered with the TECP aloft reflect higher H2O abundances than at the surface, as well as greater variance. There is evidence for saturation of the atmosphere overnight throughout much of the mission. In virtually every overnight observation, once the atmosphere cooled to T(sub f), water vapor begins to decrease, and tracks air temperature. There is no evidence for substantial decreases in water vapor prior to saturation, as expected for adsorptive exchange. Likewise, there is no evidence of local control of vapor by phases such as perchlorate hydrates hydrated minerals. The daytime average H2O pressure does not change substantially over the course of the mission, although the H2O column abundance varies by a factor of 2. Column abundances calculated from TECP data are lower than orbital measurements if one assumes that H2O is uniformly mixed through a single scale height. These results argue that the vertical distribution of H2O begins to change well in advance of surface concentrations as northern autumn approaches.

Phoenix Thermal and Electrical Conductivity Sensor

The Phoenix TECP Relative Humidity Sensor: Revised Results

The original calibration function of the RH sensor on the Phoenix mission's Thermal and Electrical Conductivity Sensor (TECP), has been revised to correct the erroneously-published original calibration equation, to demonstrate the value of this unique data set, and to improve characterization of H2O exchange between the martian regolith and atmosphere. TECP returned two data streams, the temperature of the electronics analog board (Tb) and the digital 12-bit output of the RH sensor (DN), both of which are required to uniquely specify the H2O abundance. Because the original flight instrument calibration was performed against a pair of hygrometers that measured frost point (Tf), the revised calibration equation is also cast in terms of frost point. The choice of functional form for the calibration function is minimally constrained. A series of profiles across the calibration data cloud at constant DN and Tb does not reveal any evidence of a complex functional form. Therefore, a series of polynomials in both DN and Tb was investigated, along with several non-linear functions of DN and Tb.

Phoenix mission

An Historical Search for Unfrozen Water at the Phoenix Landing Site

The goal of this work is to explore the history of the high-latitude subsurface in the latitude range of the Phoenix landing site (65-75 deg. N). The approach is to use time-marching climate models to search for times, locations, and depths where thick films of unfrozen water might periodically occur. Thick films of unfrozen water (as distinct from ubiquitous monolayer water) are interesting for two reasons. First, multi-layer films of water may be bio-available. Second, patterned ground may require the occurrence of thick films of unfrozen water to facilitate the migration of particles and the development of excess pore ice, as reported by the Odyssey Gamma Ray Spectrometer (GRS) results. For the purposes of this work, we define conditions adequate to establish thick films of unfrozen water to be T greater than 268 K, and RH greater than 0.5. We start with the need to understand the atmospheric pressure. Because of the fact that we're looking at high latitudes, the seasonal cap buffers surface temperature for some part of the year. That directly affects the subsurface thermal regime, at least in the uppermost meter where we will be

Zent, Aaron

The Decomposition of Carbonates and Organics on Mars

The return and analysis of pristine material that is relict of a putative period of chemical evolution is a fumdamental goal of the exobiological exploration of Mars. In order to accomplish this objective, it is desirable to find oxidant-free regions where pristine material can be accessed at the shallowest possible depth (ideally directly from the surface). The objective of our ongoing research is to understand the spatial and temporal distribution of oxidants in the martian regolith and the redox chemistry of the soil; in effect to understand the chemical mechanisms and kinetics relating to the in-situ destruction of organics and the formation of the reactive species responsible for the Viking biology results. In this work, we report on experimental studies of oxidizing processes that may contribute to carbonate and organic degradation on Mars. Organic molecules directly exposed to solar UV may decomposed either directly into CO2, or into more volatile organic fragments. Organic macromolecules not directly exposed to high UV flux are most likely to be affected by atmospheric oxidants which can diffuse to their surfaces. The oxidizing processes examined include: gas-phase oxidants, UV photolysis, and UV-assisted heterogeneous catalysis. For example, assuming a meteroritic infall rate of 4 x 10(exp -4) g/m^2yr (Flynn and McKay 1990) and a flux of organic carbon of 2 x 10(exp -5) g/m^2yr, laboratory measurements of the UV-assisted decomposition of benzenehexacarboxylic acid (mellitic acid, a likely intermediate of kerogen oxidation), indicate its decomposition rate on Mars would exceed the total flux of organic carbon to the planet by over four orders of magnitude. Our measurements indicate that although the decomposition temperature of kerogens in some cases exceeds the temperature limit of the Viking GCMS, it is unlikely kerogens or their decomposition intermediates were present at the Viking landings sites at levels above the GCMS detection limits.

Quinn, Richard C.