Multichannel Doppler fiber-imager spectrometer for spatiotemporal characterization of high-intensity laser-driven plasmas

Here, we demonstrate a flexible multichannel fiber-based imaging Doppler spectrometer to characterize plasmas in high intensity (≥1 × 10 18 W/cm 2 ) laser-plasma experiments at high repetition rates. This instrument collects data from ×21 different plasma locations combining optical fibers and a single imaging spectrometer. This diagnostic maps the plasma velocity evolution as a function of time with sub-pico-second resolution. Experimental results showing 2D velocity measurements of plasma with 20 μm spatial resolution are presented. Intensities of the order of 10 18 W/cm 2 were used to generate a plasma, while a much less intense, frequency doubled (400 nm), probe beam (10 11 W/cm 2 ) was used to measure the Doppler shift from the plasma critical surface. The instrument can be scaled to a larger number of channels (e.g., 100) still using a single spectrometer.

47 OTHER INSTRUMENTATION↗

A flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ~3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. Here, we also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

3D printing↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Single-shot measurements of pulse-front tilt in intense ps laser pulses and its effect on accelerated electron and ion beam characteristics (invited)

Here we report recent single-shot spatiotemporal measurements of laser pulses, including pulse-front tilt (PFT) and spatial chirp, taken at the Compact Multipulse Terawatt laser at the Jupiter Laser Facility in Livermore, CA. STRIPED FISH, a device that measures the complete 3D electric field of fs to ps laser pulses on a single shot, was adapted to near infrared for these measurements. We present the design of the instrument used for these experiments, the on-shot measurements of systematic high-order PFT, and shot-to-shot variations in the measurements of spatiotemporal couplings. Finally, we simulate the effect of PFT in target normal sheath acceleration experiments. These simulations showed that pulse front tilt can steer hot electrons, shape the distribution of the accelerating sheath field, and increase the variability of cutoff energy in the resulting proton spectra. While these effects may be detrimental to experimental accuracy if the pulse front tilt is left unmeasured, hot electron steering shows promise for precision manipulation of the particle source for a range of applications, including irradiation of secondary targets for opacity measurements, radiography, or neutron generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.