Search NASA⌕ Search

Engineering topics

Zhang, Da

Publications and source records attributed to Zhang, Da.

At least 19 records

Spatially resolved land and grid model of carbon neutrality in China

China has committed to achieve net carbon neutrality by 2060 to combat global climate change, which will require unprecedented deployment of negative emissions technologies, renewable energies (RE), and complementary infrastructure. At terawatt-scale deployment, land use limitations interact with operational and economic features of power systems. To address this, we developed a spatially resolved resource assessment and power systems planning optimization that models a full year of power system operations, sub-provincial RE siting criteria, and transmission connections. Our modeling results show that wind and solar must be expanded to 2,000 to 3,900 GW each, with one plausible pathway leading to 300 GW/yr combined annual additions in 2046 to 2060, a three-fold increase from today. Over 80% of solar and 55% of wind is constructed within 100 km of major load centers when accounting for current policies regarding land use. Large-scale low-carbon systems must balance key trade-offs in land use, RE resource quality, grid integration, and costs. Under more restrictive RE siting policies, at least 740 GW of distributed solar would become economically feasible in regions with high demand, where utility-scale deployment is limited by competition with agricultural land. Effective planning and policy formulation are necessary to achieve China’s climate goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Herding Cats: Firm Non-Compliance in China’s Industrial Energy Efficiency Program

Here we study firm responses to a large-scale energy efficiency program in China, focusing on the quality of reporting and compliance outcomes. Using statistical methods to detect data manipulation in compliance reports, we find evidence that firms deliberately exaggerated performance during the first phase of the program (2006-2010), suggesting the high compliance rate was overstated. In its second phase (2011-2015), the number of firms in the program expanded by an order of magnitude, and the compliance rate decreased. We develop a simple model to show how the observed increase in non-compliance is consistent with reduced misreporting. Statistical tests find no evidence of manipulation in the second phase. Larger firms, especially those not controlled by the state, and firms in cities with relatively low growth were more likely to report non-compliance, which suggests a role for state control and local protectionism in shaping compliance decisions. Based on our findings, we offer several lessons for future program design.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Health co-benefits of achieving sustainable net-zero greenhouse gas emissions in California

The achievement of net-zero greenhouse gas (GHG) emissions by 2100 is required to limit global temperature rise below 2 °C above preindustrial levels. Earlier accomplishments of net-zero GHG emissions in developed regions support this global target. In this study, we have developed a road map for California to achieve net-zero GHG emissions sustainably in 2050 by using detailed modelling of energy system transformation, cross-sectoral connectivity and technology penetration, as well as quantify the associated health co-benefits from reduced co-emitted air pollutants. We find that approximately 14,000 premature deaths can be avoided in California in 2050 and that these health co-benefits are disproportionately higher in disadvantaged communities (that is, 35% of avoided deaths will come from 25% of the state’s population). The annualized monetary benefits (US$215 billion) exceed the GHG abatement cost (US$106 billion) by US$109 billion. This road map requires the use of bioenergy with carbon capture and sequestration technology to offset some GHG emissions. However, this technology comes at a price as it would emit a considerable amount of air pollutants and reduce health co-benefits by US$4 billion. Nevertheless, our analysis shows that ambitious GHG reduction efforts can provide substantial health co-benefits, especially for residents of disadvantaged communities.

54 ENVIRONMENTAL SCIENCES↗

Cross talk between RNA N6‐methyladenosine methyltransferase‐like 3 and miR‐186 regulates hepatoblastoma progression through Wnt/β‐catenin signalling pathway

Abstract Objectives N6‐methyladenosine (m6A) is a ubiquitous epigenetic RNA modification that plays a pivotal role in tumour development and metastasis. In this study, we aimed to investigate the expression profiling, clinical significance, biological function and the regulation of m6A‐related genes in hepatoblastoma (HB). Materials and Methods The mRNA and protein expression levels of m6A‐related genes were analysed using Gene Expression Omnibus (GEO) and tissue microarray (TMA) cohort. Kaplan‐Meier analysis was performed to evaluate the prognostic value of m6A‐related genes in HB. Knockdown of m6A‐related genes was conducted to analyse its function on cell proliferation, migration and invasion. Furthermore, bioinformatics analysis and experimental verification were used to explore the potential molecular mechanism and signalling pathway. Results We found that most m6A‐related genes were significantly upregulated in HB tumour tissues. High levels of methyltransferase‐like 3 (METTL3, P = .013), YTHDF2 ( P = .037) and FTO ( P = .032) indicated poor clinical outcomes, and the upregulation of METTL3 was an independent prognostic factor in HB patients. Functional assays showed that knockdown of METTL3 could dramatically suppress the proliferation, migration and invasion of HB cells. In addition, METTL3 was identified to be a direct target of microRNA‐186 (miR‐186). Consistently, miR‐186 was low expressed in HB tumour tissues. Moreover, overexpression of miR‐186 significantly inhibited cell aggressive phenotype both in vitro and in vivo, while the inhibitory effect could be reversed by METTL3 overexpression. Mechanism study indicated that miR‐186/METTL3 axis contributed to the progression of HB via the Wnt/β‐catenin signalling pathway. Conclusions M6A‐related genes were frequently dysregulated in HB. miR‐186/METTL3/Wnt/β‐catenin axis might serve as novel therapeutic targets and prognostic biomarkers in HB.

Cui, Xichun↗

Spatiotemporal Arbitrage of Large-Scale Portable Energy Storage for Grid Congestion Relief

Energy storage has great potential in grid congestion relief. By making large-scale energy storage portable through trucking, its capability to address grid congestion can be greatly enhanced. This paper explores the business model of large-scale portable energy storage for spatiotemporal arbitrage over nodes with congestion. We propose a spatiotemporal arbitrage model to determine the optimal operation and transportation schedules of portable storage. To validate the business model, we simulate the schedules of a Tesla Semi full of Tesla Powerpack doing arbitrage over two nodes in California with local transmission congestion. The results indicate that the contributions of portable storage to congestion relief are much greater than that of stationary storage, and that trucking storage can bring net profit in energy arbitrage applications.

He, Guannan↗

Regional power system modeling for evaluating renewable energy development and CO2 emissions reduction in China

Highlights: • We introduce a capacity expansion and operation model for China's power system. • Reference carbon emissions of China's power sector exceed 5.1 billion tons in 2050. • Flexible district heating marginally increases the integration of renewable energy. • Ultra-high voltage transmission does not improve the integration by itself. • A complete spot market as a policy change could be crucial for the integration. - Abstract: This study demonstrates how a regional power system modeling tool could be applied to evaluate renewable energy development and emissions reduction with technology change and market reform. We introduce a capacity expansion and operation model with provincial details for China's power system – the Renewable Electricity Planning and Operation (REPO) Model. We compare the spatial and temporal variation of renewable energy development under three alternative scenarios that depict three potentially important technology and reform directions – flexible district heating technology, ultra-high voltage transmission technology and complete spot market to the reference scenario. Under the reference scenario, the share of non-hydro renewable energy in China's power sector will reach 11.3% and carbon emissions of the power sector will increase to 5.1 billion metric tons in 2050. With assumptions made in the flexible district heating technology, ultra-high voltage transmission technology and complete spot market scenario, the share of non-hydro renewable energy in the power sector could increase to 14.3%, 11.5%, and 23.7%, and carbon emissions of power sector will change by −0.3, +0.0, and −1.0 billion metric tons in 2050, respectively. Similar analyses could be extended to other developing countries that plan to deregulate and decarbonize their power systems.

54 ENVIRONMENTAL SCIENCES↗

RBM14 is indispensable for pluripotency maintenance and mesoderm development of mouse embryonic stem cells

Highlights: • RBM14 knockout mouse embryonic stem cells were successfully generated. • RBM14 depletion altered gene expression profiles in mouse embryonic stem cells. • RBM14 depletion impeded mesoderm development in vitro. • RBM14 depletion impeded mesoderm development in vivo. The pluripotency of embryonic stem cells (ESCs) is maintained by core pluripotency transcription factors, cofactors and several signaling pathways. RBM14 is a component of the para-speckle complex, which has been implicated in multiple important biological processes. The role of RBM14 in ESCs and lineage differentiation remains to be elucidated. In the present study, we provided evidence that RBM14 plays important roles in maintaining pluripotency and in the early differentiation of ESCs. RBM14 was demonstrated to be expressed in mouse embryonic stem cells (mESCs) and localized in the nucleus. RBM14 expression was depleted in mESCs using clustered regularly interspaced short palindromic repeats (CRISPR) technology. Our results also showed that RBM14 depletion altered the gene expression profiles of mESCs. In particular, pluripotency-associated genes and genes involved in the Wnt and TGF-β signaling pathways were downregulated in RBM14 knockout mESCs. Furthermore, RBM14 was found to be essential for mesoderm development in vitro and in vivo. The specific effects of RBM14 depletion were verified by conducting a rescue experiment. Our findings demonstrated that RBM14 not only plays an important role in maintaining the pluripotency of mESCs but is also indispensable for mesoderm development.

60 APPLIED LIFE SCIENCES↗

PKC and Rab13 mediate Ca2+ signal-regulated GLUT4 traffic

Highlights: • Ionomycin increases cell surface GLUT4 levels by inhibiting GLUT4 endocytosis and promoting GLUT4 exocytosis. • PKCα and PKCθ are involved in ionomycin-regulated GLUT4 endocytosis. • PKCθ regulates GLUT4 exocytosis in response to ionomycin. • Rab13 is required for ionomycin-promoted GLUT4 exocytosis. Exercise/muscle contraction increases cell surface glucose transporter 4 (GLUT4), leading to glucose uptake to regulate blood glucose level. Elevating cytosolic Ca{sup 2+} mediates this effect, but the detailed mechanism is not clear yet. We used calcium ionophore ionomycin to raise intracellular cytosolic Ca{sup 2+} level to explore the underlying mechanism. We showed that in L6 myoblast muscle cells stably expressing GLUT4myc, ionomycin increased cell surface GLUT4myc levels and the phosphorylation of AS160, TBC1D1. siPKCα and siPKCθ but not siPKCδ and siPKCε inhibited the ionomycin-increased cell surface GLUT4myc level. siPKCα, siPKCθ inhibited the phosphorylation of AS160 and TBC1D1 induced by ionomycin. siPKCα and siPKCθ prevented ionomycin-inhibited endocytosis of GLUT4myc. siPKCθ, but not siPKCα inhibited ionomycin-stimulated exocytosis of GLUT4myc. siRab13 but not siRab8a, siRab10 and siRab14 inhibited the exocytosis of GLUT4myc promoted by ionomycin. In summary, ionomycin-promoted exocytosis of GLUT4 is partly reversed by siPKCθ, whereas ionomycin-inhibited endocytosis of GLUT4 requires both siPKCα and siPKCθ. PKCα and PKCθ contribute to ionomycin-induced phosphorylation of AS160 and TBC1D1. Rab13 is required for ionomycin-regulated GLUT4 exocytosis.

60 APPLIED LIFE SCIENCES↗

A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations

Purpose: To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. Methods: A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was used to simultaneously detect radiation levels across a scan field-of-view. The sampling time was as short as 0.24 ms. To measure the body bow-tie attenuation on a GE Lightspeed Pro 16 CT scanner, the x-ray tube was parked at the 12 o’clock position, and the detector was centered in the scan field at the isocenter height. Two radiation exposures were made with and without the bow-tie in the beam path. Each readout signal was corrected for the detector background offset and signal-level related nonlinear gain, and the ratio of the two exposures gave the bow-tie attenuation. The results were used in the GEANT4 based simulations of the point doses measured using six thimble chambers placed in a human cadaver with abdomen/pelvis CT scans at 100 or 120 kV, helical pitch at 1.375, constant or variable tube current, and distinct x-ray tube starting angles. Results: Absolute attenuation was measured with the body bow-tie scanned at 80–140 kV. For 24 doses measured in six organs of the cadaver, the median or maximum difference between the simulation results and the measurements on the CT scanner was 8.9% or 25.9%, respectively. Conclusions: The described method allows fast and accurate bow-tie filter characterization.

60 APPLIED LIFE SCIENCES↗

CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D{sub L}(0) and its rise-to-the-equilibrium curve H(L) = D{sub L}(0)/D{sub eq} from computed tomography (CT) scanning, where D{sub eq} is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm{sup 3} thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E{sub in}/E or E{sub out}/E) on the phantom central and peripheral axes, where E = LD{sub eq} was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose ratios changed with beam aperture and phantom axis but were insensitive to tube voltage. H(L) was insensitive to tube voltage and CT scanner model. As phantom diameter increased from 6 to 55 cm, E{sub in}/E generally decreased but asymptotically approached constant levels on the peripheral axes of large phantoms. The curve of E{sub in}/E versus scan length was almost identical to that of H(L). Similarly, E{sub out}/E increased with scan length and asymptotically approached the equilibrium for large scan lengths. E{sub out}/D{sub eq} was much less than the equilibrium length L{sub eq} where H(L) = 0.98, even with scan lengths much larger than L{sub eq}. Conclusions: The polyethylene phantom designed by ICRU Report No. 87 Committee and AAPM Task Group 200 is adequately long for assessing the midpoint dose and its equilibration in CT scanning. The short-to-long phantom dose ratios and the H(L) data provided in this paper allow easy evaluations of the midpoint dose, longitudinal dose distribution, and energy absorption in polyethylene phantoms. The results of dose equilibration and energy absorption presented herein may be insightful for the clinical CT scans with various subject sizes and scan lengths.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation dose calculations for CT scans with tube current modulation using the approach to equilibrium function

Purpose: The approach to equilibrium function has been used previously to calculate the radiation dose to a shift-invariant medium undergoing CT scans with constant tube current [Li, Zhang, and Liu, Med. Phys. 39, 5347–5352 (2012)]. The authors have adapted this method to CT scans with tube current modulation (TCM). Methods: For a scan with variable tube current, the scan range was divided into multiple subscan ranges, each with a nearly constant tube current. Then the dose calculation algorithm presented previously was applied. For a clinical CT scan series that presented tube current per slice, the authors adopted an efficient approach that computed the longitudinal dose distribution for one scan length equal to the slice thickness, which center was at z = 0. The cumulative dose at a specific point was a summation of the contributions from all slices and the overscan. Results: The dose calculations performed for a total of four constant and variable tube current distributions agreed with the published results of Dixon and Boone [Med. Phys. 40, 111920 (14pp.) (2013)]. For an abdomen/pelvis scan of an anthropomorphic phantom (model ATOM 701-B, CIRS, Inc., VA) on a GE Lightspeed Pro 16 scanner with 120 kV, N × T = 20 mm, pitch = 1.375, z axis current modulation (auto mA), and angular current modulation (smart mA), dose measurements were performed using two lines of optically stimulated luminescence dosimeters, one of which was placed near the phantom center and the other on the surface. Dose calculations were performed on the central and peripheral axes of a cylinder containing water, whose cross-sectional mass was about equal to that of the ATOM phantom in its abdominal region, and the results agreed with the measurements within 28.4%. Conclusions: The described method provides an effective approach that takes into account subject size, scan length, and constant or variable tube current to evaluate CT dose to a shift-invariant medium. For a clinical CT scan, dose calculations may be performed with a water-containing cylinder whose cross-sectional mass is equal to that of the subject. This method has the potential to substantially improve evaluations of patient dose from clinical CT scans, compared to CTDI{sub vol}, size-specific dose estimate (SSDE), or the dose evaluated for a TCM scan with a constant tube current equal to the average tube current of the TCM scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In vitro dose measurements in a human cadaver with abdomen/pelvis CT scans

Purpose: To present a study of radiation dose measurements with a human cadaver scanned on a clinical CT scanner. Methods: Multiple point dose measurements were obtained with high-accuracy Thimble ionization chambers placed inside the stomach, liver, paravertebral gutter, ascending colon, left kidney, and urinary bladder of a human cadaver (183 cm in height and 67.5 kg in weight) whose abdomen/pelvis region was scanned repeatedly with a multidetector row CT. The flat energy response and precision of the dosimeters were verified, and the slight differences in each dosimeter's response were evaluated and corrected to attain high accuracy. In addition, skin doses were measured for radiosensitive organs outside the scanned region with OSL dosimeters: the right eye, thyroid, both nipples, and the right testicle. Three scan protocols were used, which shared most scan parameters but had different kVp and mA settings: 120-kVp automA, 120-kVp 300 mA, and 100-kVp 300 mA. For each protocol three repeated scans were performed. Results: The tube starting angle (TSA) was found to randomly vary around two major conditions, which caused large fluctuations in the repeated point dose measurements: for the 120-kVp 300 mA protocol this angle changed from approximately 110° to 290°, and caused 8% − 25% difference in the point dose measured at the stomach, liver, colon, and urinary bladder. When the fluctuations of the TSA were small (within 5°), the maximum coefficient of variance was approximately 3.3%. The soft tissue absorbed doses averaged from four locations near the center of the scanned region were 27.2 ± 3.3 and 16.5 ± 2.7 mGy for the 120 and 100-kVp fixed-mA scans, respectively. These values were consistent with the corresponding size specific dose estimates within 4%. The comparison of the per-100-mAs tissue doses from the three protocols revealed that: (1) dose levels at nonsuperficial locations in the TCM scans could not be accurately deduced by simply scaling the fix-mA doses with local mA values; (2) the general power law relationship between dose and kVp varied from location to location, with the power index ranged between 2.7 and 3.5. The averaged dose measurements at both nipples, which were about 0.6 cm outside the prescribed scan region, ranged from 23 to 27 mGy at the left nipple, and varied from 3 to 20 mGy at the right nipple over the three scan protocols. Large fluctuations over repeated scans were also observed, as a combined result of helical scans of large pitch (1.375) and small active areas of the skin dosimeters. In addition, the averaged skin dose fell off drastically with the distance to the nearest boundary of the scanned region. Conclusions: This study revealed the complexity of CT dose fluctuation and variation with a human cadaver.

60 APPLIED LIFE SCIENCES↗