Search NASA⌕ Search

Engineering topics

Zhang, Dong

Publications and source records attributed to Zhang, Dong.

RNA-Puzzles Round V: blind predictions of 23 RNA structures

RNA-Puzzles is a collective endeavor dedicated to the advancement and improvement of RNA three-dimensional structure prediction. With agreement from structural biologists, RNA structures are predicted by modeling groups before publication of the experimental structures. We report a large-scale set of predictions by 18 groups for 23 RNA-Puzzles: 4 RNA elements, 2 Aptamers, 4 Viral elements, 5 Ribozymes and 8 Riboswitches. We describe automatic assessment protocols for comparisons between prediction and experiment. Our analyses reveal some critical steps to be overcome to achieve good accuracy in modeling RNA structures: identification of helix-forming pairs and of non-Watson–Crick modules, correct coaxial stacking between helices and avoidance of entanglements. Three of the top four modeling groups in this round also ranked among the top four in the CASP15 contest.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Saccadic Component Measure on Smooth Pursuit Tests

ABSTRACT Introduction Despite the advancement of eye-tracking technology for smooth pursuit (SP) eye movement evaluation, qualitative observation offers much information that is not captured by computers; hence, both objective and qualitative information should be utilized to evaluate SP. This study examined the consistency among our clinicians when evaluating SP using normal (N), grossly normal (GN), mildly abnormal (MA), and abnormal (AB) as classifications. We then evaluated the effect of combining GN and MA into a single subclinical (SUBC) category. We also evaluated the computerized percent saccade (PS) metric by determining its sensitivity and specificity in classifying SP. Materials and Methods Retrospective horizontal and vertical SP test videos and numerical data for 70 participants were obtained from the Neuro Kinetics Neuro-Otologic Test Center and de-identified. From this, eye-tracking videos, time plots of eye-tracking positional data, and tables of SP eye-tracking performance data were generated for 0.1, 0.3, and 0.5 Hz in both horizontal and vertical planes, totaling 6 tests per subject. Three clinicians rated each subject’s SP performance as N, GN, MA, or AB for a total of 6 ratings (3 frequencies, horizontal and vertical). This process was repeated using N, SUBC, and AB as rating categories. Clinicians also provided an overall SP rating for each plane as follows: AB if the results were abnormal for 2 or more frequencies tested. Alternatively, if fewer than 2 frequencies presented with a rating of AB, then an overall rating of MA, GN, or N was determined at the respective clinician’s discretion. Results When the 3 clinicians were tasked with classifying SP videos using 4 clinical categories, fair overall agreement was demonstrated. However, when MA and GN categories were combined into an SUBC category, the overall agreement for the 3 clinicians improved slightly for both horizontal SP (HSP) and vertical SP (VSP). This pattern of agreement did not differ considerably when comparing HSP versus VSP, and good consistency and reliability was observed across clinicians. Again, inter-rater consistency was smaller for VSP versus HSP despite the reduction in clinical categories. Cut-off values were generated for the PS metric and demonstrated good specificity and sensitivity when they were exceeded for 2 or more frequencies in a particular plane when evaluating a subject’s SP test. Conclusions

General & Internal Medicine↗

Comparative Performance of Three Eye-Tracking Devices in Detection of Mild Traumatic Brain Injury in Acute Versus Chronic Subject Populations

ABSTRACT Introduction Presently, traumatic brain injury (TBI) triage in field settings relies on symptom-based screening tools such as the updated Military Acute Concussion Evaluation. Objective eye-tracking may provide an alternative means of neurotrauma screening due to sensitivity to neurotrauma brain-health changes. Previously, the US Army Medical Research and Development Command Non-Invasive NeuroAssessment Devices (NINAD) Integrated Product Team identified 3 commercially available eye-tracking devices (SyncThink EYE-SYNC, Oculogica EyeBOX, NeuroKinetics IPAS) as meeting criteria toward being operationally effective in the detection of TBI in service members. We compared these devices to assess their relative performance in the classification of mild traumatic brain injury (mTBI) subjects versus normal healthy controls. Materials and Methods Participants 18 to 45 years of age were assigned to Acute mTBI, Chronic mTBI, or Control group per study criteria. Each completed a TBI assessment protocol with all 3 devices counterbalanced across participants. Acute mTBI participants were tested within 72 hours following injury whereas time since last injury for the Chronic mTBI group ranged from months to years. Discriminant analysis was undertaken to determine device classification performance in separating TBI subjects from controls. Area Under the Curves (AUCs) were calculated and used to compare the accuracy of device performance. Device-related factors including data quality, the need to repeat tests, and technical issues experienced were aggregated for reporting. Results A total of 63 participants were recruited as Acute mTBI subjects, 34 as Chronic mTBI subjects, and 119 participants without history of TBI as controls. To maximize outcomes, poorer quality data were excluded from analysis using specific criteria where possible. Final analysis utilized 49 (43 male/6 female, mean [x̅] age = 24.3 years, SD [s] = 5.1) Acute mTBI subjects, and 34 (33 male/1 female, x̅ age = 38.8 years, s = 3.9) Chronic mTBI subjects were age- and gender-matched as closely as possible with Control subjects. AUCs obtained with 80% of total dataset ranged from 0.690 to 0.950 for the Acute Group and from 0.753 to 0.811 for the Chronic mTBI group. Validation with the remaining 20% of dataset produced AUCs ranging from 0.600 to 0.750 for Acute mTBI group and 0.490 to 0.571 for the Chronic mTBI group. Conclusions Potential eye-tracking detection of mTBI, per training model outcomes, ranged from acceptable to excellent for the Acute mTBI group; however, it was less consistent for the Chronic mTBI group. The self-imposed targeted performance (AUC of 0.850) appears achievable, but further device improvements and research are necessary. Discriminant analysis models differed for the Acute versus Chronic mTBI groups, suggesting performance differences in eye-tracking. Although eye-tracking demonstrated sensitivity in the Chronic group, a more rigorous and/or longitudinal study design is required to evaluate this observation. mTBI injuries were not controlled for this study, potentially reducing eye-tracking assessment sensitivity. Overall, these findings indicate that while eye-tracking remains a viable means of mTBI screening, device-specific variability in data quality, length of testing, and ease of use must be addressed to achieve NINAD objectives and DoD implementation.

General & Internal Medicine↗

Profile of Twenty-Three Human Milk Oligosaccharides in Han Chinese Mothers throughout Postpartum 1 year

Human milk oligosaccharides (HMOs) are multifunctional carbohydrates in breast milk, which are composed by a variety of structures. This study aimed to identified HMOs concentration profile, milk microbiota composition, and the associations with major maternal characteristics in Han Chinese mothers in the one-year lactation period. Seventeen healthy mothers aged from 28 to 36 years, who gave birth to healthy term infants, were recruited. Carbohydrates were detected using the MIRIS human milk analyzer (HMA), and twenty-three HMOs were quantified using ultra-performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-MS). Results showed that carbohydrates were relatively stable, while total HMO concentrations ranged from 1.74 to 9.72 g/L and decreased gradually over lactation in breast milk. Based on the structure, seven sialylated HMOs concentration showed the significant decline ( p < 0.05 ) after three months in lactation. In addition, the relationships between maternal factors, containing the lactation period, genetic status, delivery mode, parity, and milk microbiota profile, and the HMO composition in healthy women, which still need further investigations, were observed.

Xun, Yiping↗

An anti-PD-1–GITR-L bispecific agonist induces GITR clustering-mediated T cell activation for cancer immunotherapy

Costimulatory receptors such as glucocorticoid-induced tumor necrosis factor receptor–related protein (GITR) play key roles in regulating the effector functions of T cells. In human clinical trials, however, GITR agonist antibodies have shown limited therapeutic effect, which may be due to suboptimal receptor clustering-mediated signaling. To overcome this potential limitation, a rational protein engineering approach is needed to optimize GITR agonist-based immunotherapies. Here we show a bispecific molecule consisting of an anti-PD-1 antibody fused with a multimeric GITR ligand (GITR-L) that induces PD-1-dependent and FcγR-independent GITR clustering, resulting in enhanced activation, proliferation and memory differentiation of primed antigen-specific GITR + PD-1 + T cells. The anti-PD-1–GITR-L bispecific is a PD-1-directed GITR-L construct that demonstrated dose-dependent, immunologically driven tumor growth inhibition in syngeneic, genetically engineered and xenograft humanized mouse tumor models, with a dose-dependent correlation between target saturation and Ki67 and TIGIT upregulation on memory T cells. Anti-PD-1–GITR-L thus represents a bispecific approach to directing GITR agonism for cancer immunotherapy.

60 APPLIED LIFE SCIENCES↗

Investigation of interlayer adhesion of 3D printable cementitious material from the aspect of printing process

The safety of structure printed by extrusion-based 3D concrete printing (3DCP) is significantly influenced by interlayer bonding, which is governed by fresh material properties and processes, including mixing, printing, and post-processing phases. Much literature focused on improving interlayer bond strength via material tailoring/bonding agent addition but gave insufficient attention to other phases' impacts. This study investigates the effects of parameters on interlayer bond strength from different phases in 3DCP, including superplasticizer dosage, printing speed, and curing condition. In the mixing phase, the superplasticizer dosage was increased to reduce I{sub thix} and increase surface moisture content (SMC), consequently improving interface microstructure and interlayer bond strength. In the printing phase, similar results were observed by increasing pumping speed to increase material shear rate. In the post-processing phase, proper curing also improved interlayer bond strength. While SMC has a critical impact on interlayer bond strength, material thixotropic index (I{sub thix}) probably has a stronger influence.

36 MATERIALS SCIENCE↗

Effect of spatial distribution of polymer fibers on preventing spalling of UHPC at high temperatures

Polypropylene (PP) fibers are commonly used for the prevention of thermal spalling of ultra-high performance concrete (UHPC). In this work, the effect of fiber distribution on permeability and spalling resistance is investigated and an analytical model for permeability at 150 °C is proposed. This model, considering the parameters like fiber dimensions, dosage, and percolation, is based on Kozeny-Carman equation. It was found that the percolation of the interconnecting fiber network resulted in a significant increase in permeability of UHPC. X-ray tomography data on the three-dimensional spatial distribution of fibers reiterated that fiber aspect ratio and dosage (and fiber number density) were critical in increasing the fiber connectivity (percolation). It was also found that a vapor permeability of larger than 0.6 × 10{sup −16} m{sup 2} at 150 °C could eliminate spalling. Further, based on a semi-empirical approach, aspect ratio between 300 and 600 was recommended for spalling prevention with a fiber dosage of 0.3–0.4 vol%.

36 MATERIALS SCIENCE↗