Search NASA⌕ Search

Engineering topics

Zhang, Feng-Yuan (ORCID:0000000325350966)

Publications and source records attributed to Zhang, Feng-Yuan (ORCID:0000000325350966).

Combining Distributed Electrochemical Measurements with a Semi-Empirical Model to Identify Local Variations in Overpotentials for PEM Water Electrolyzers

Abstract A segmented cell and PCB approach was used to demonstrate an advanced technique for measuring and understanding the electrochemical behavior of PEM water electrolyzers. By employing a semi-empirical model, discrete modes of overpotential and their spatial distributions were identified in an operating cell. Distributed area-specific resistance (DASR measurements indicate that local dehydration of the polymer electrolyte membrane is the primary driver of increased polarization, behaving similarly to mass transport-limited currents at low flow rates due to ineffective gas-phase bubble removal. To improve quantification, the overall ohmic overpotential is divided into background (η Ohm,b ) and mass transport-coupled (η Ohm,mt ) components. Two types of anode diffusion media, a baseline PTL and a thin foil liquid/gas diffusion layer (LGDL), were examined. The results show significant variations in η Ohm,b and highlight that ineffective bubble removal leads to pronounced local dehydration. The effect of cell temperature on various overpotentials was also examined. Negligible differences in diffusion overpotential were observed when comparing PEWE performance using the PTL and LGDL, despite major differences in two-phase fluid transport within each diffusion media. This underscores the critical role of the catalyst layer's micro-porous structure in diffusion processes. The study highlights the complex nature and intricacies of mass transport limitations within PEWEs.

Roy, Anirban (ORCID:0000000163803386)↗

EWTN: Quantifying Mass Transport to Enable Water Electrolyzer Architectures with Low Flow-Rate Sensitivity

To develop cost-effective and high-performing polymer electrolyte water electrolyzers (PEWEs) for gigawatt-scale applications, researchers have focused on reducing precious metal catalyst loadings and optimizing porous transport layers. However, the performance of PEWEs is also affected by system architecture. Mass transport losses are dependent on localized architecture and material interactions. In-situ measurements, such as current density distribution maps have demonstrated advantages in understanding the intricate characteristics and influence of two-phase flow within PEWEs. This study proposes the parameter of effective water transport number (EWTN) as a quantitative tool to investigate such current density distribution (CDD) measurements for PEWEs. Results show that higher flow-rates have EWTN values of 0.95 and above, indicating no mass transport limitations; while lower flow-rates with large gradients CDD have EWTN values between 0.6-0.8, indicating mass transport limited conditions. The new analysis also identified a correlation between mass transport losses due to bubble accumulation, membrane hydration, and ohmic overpotentials. To address these limitations, an unitized pin-type LGDL/flow-field design was developed, which effectively prevents local gas phase accumulation, resulting in improved mass transport characteristics. The results of this work show reduced flow-rate sensitivity with the pin-type architecture and ∼13% increased performance at 0.24 ml / min / cm 2 .

Electrochemistry↗