Search NASA⌕ Search

Engineering topics

Zhang, H

Publications and source records attributed to Zhang, H.

At least 55 records · Page 3

SU-E-T-272: Radiation Damage Comparison Between Intensity Modulated Radiotherapy and Field-In-Field Technique in Breast Cancer Treatments

Purpose: To compare normal tissue complications between IMRT and FIF treatment in breast cancer. Methods: 16 patients treated with IMRT plan and 20 patients treated with FIF plan were evaluated in this study. Both kinds of plans were generated using Eclipse treatment planning system by dosimetrist following clinical radiotherapy treatment guidelines. The plans were reviewed and approved by radiation oncologist. The average survival fraction (SF) for three different normal tissue cells of each concerned structure can be calculated from differential dose volume histogram (DVH) using linear quadratic model. The three types of normal tissues include radiosensitive, moderately radiosensitive and radio-resistant that represents 70%, 50% and 30% survival fractions, respectively, for a 2-Gy open field. Equivalent uniform doses (EUD) for corresponding normal tissues of each structure were calculated. Results: The EUDs of the lungs, heart, healthy breast and spinal cord with both IMRT and FIF treatments were calculated. Considering the average value of all IMRT plans, the lung of treated side absorbed 16.0% of dosage prescribed to the tumor if the radiosensitivity of the lung is similar to the radiosensitive cell line. For moderately radiosensitive and radio-resistant lung tissue, the average EUDs can be 18.9% and 22.4% of prescription. In contrast, patients treated with FIF plans were delivered 6.0%, 7.5% and 10.3% of prescribed dose for radiosensitive, moderately radiosensitive and radio-resistant lung tissue, respectively. Comparing heart EUDs between IMRT and FIF plans, average absorbed doses in IMRT treatment were 7.7%, 8.7% and 9.7% of prescription for three types of heart normal tissue cell lines while FIF treatments delivered only 1.3%, 1.5% and 1.6% of prescription dose. For the other organs, the results were similar. Conclusion: The results indicated that breast cancer treatment using IMRT technique had more normal tissue damage than FIF treatment. FIF demonstrated more effective normal tissue dose reduction in breast cancer treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-387: Achieving Optimal Patient Setup Imaging and Treatment Workflow Configurations in Multi-Room Proton Centers

Purpose: To simulate patient flow in proton treatment center under uncertainty and to explore the feasibility of treatment preparation rooms to improve patient throughput and cyclotron utilization. Methods: Three center layout scenarios were modeled: (S1: In-Tx room imaging) patient setup and imaging (planar/volumetric) performed in treatment room, (S2: Patient setup in preparation room) each treatment room was assigned with preparation room(s) that was equipped with lasers only for patient setup and gross patient alignment, and (S3: Patient setup and imaging in preparation room) preparation room(s) was equipped with laser and volumetric imaging for patient setup, gross and fine patient alignment. A 'snap' imaging was performed in treatment room. For each scenario, the number of treatment rooms and the number of preparation rooms serving each treatment room were varied. We examined our results (average of 100 16-hour (two shifts) working days) by evaluating patient throughput and cyclotron utilization. Results: When the number of treatment rooms increased ([from, to]) [1, 5], daily patient throughput increased [32, 161], [29, 184] and [27, 184] and cyclotron utilization increased [13%, 85%], [12%, 98%], and [11%, 98%] for scenarios S1, S2 and S3 respectively. However, both measures plateaued after 4 rooms. With the preparation rooms, the throughput and the cyclotron utilization increased by 14% and 15%, respectively. Three preparation rooms were optimal to serve 1-3 treatment rooms and two preparation rooms were optimal to serve 4 or 5 treatment rooms. Conclusion: Patient preparation rooms for patient setup may increase throughput and decrease the need for additional treatment rooms (cost effective). Optimal number of preparation rooms serving each gantry room varies as a function of treatment rooms and patient setup scenarios. A 5th treatment room may not be justified by throughput or utilization.

43 PARTICLE ACCELERATORS↗

SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according to the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.

60 APPLIED LIFE SCIENCES↗

Pressure-induced amorphization in orthorhombic Ta{sub 2}O{sub 5}: An intrinsic character of crystal

The phase transition of orthorhombic Ta{sub 2}O{sub 5} was investigated by in situ synchrotron X-ray diffraction and Raman spectroscopy. The orthorhombic phase transforms into an amorphous form completely at 24.7 GPa. A bulk modulus B{sub 0} = 139 (9) GPa for the orthorhombic Ta{sub 2}O{sub 5} is derived from the P-V data. We suggest that the pressure-induced amorphization (PIA) in Ta{sub 2}O{sub 5} can be attributed to the unstability of the a axis under high pressure leads to the connections of polyhedral breaking down and even triggers disorder of the whole crystal frame. These results demonstrate that the PIA is an intrinsic character of Ta{sub 2}O{sub 5} which depends on its orthorhombic crystal structure rather than nanosize effects. This study provides a new kind of bulk material for investigating PIA in metal oxides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural phase transition of BaZrO{sub 3} under high pressure

We studied the phase transition behavior of cubic BaZrO{sub 3} perovskite by in situ high pressure synchrotron X-ray diffraction experiments up to 46.4 GPa at room temperature. The phase transition from cubic phase to tetragonal phase was observed in BaZrO{sub 3} for the first time, which takes place at 17.2 GPa. A bulk modulus 189 (26) GPa for cubic BaZrO{sub 3} is derived from the pressure–volume data. Upon decompression, the high pressure phase transforms into the initial cubic phase. It is suggested that the unstable phonon mode caused by the rotation of oxygen octahedra plays a crucial role in the high pressure phase transition behavior of BaZrO{sub 3}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Easily Regenerable Solid Adsorbents Based on Polyamines for Carbon Dioxide Capture from the Air

Adsorbents prepared easily by impregnation of fumed silica with polyethylenimine (PEI) are promising candidates for the capture of CO2 directly from the air. These inexpensive adsorbents have high CO2 adsorption capacity at ambient temperature and can be regenerated in repeated cycles under mild conditions. Despite the very low CO2 concentration, they are able to scrub efficiently all CO2 out of the air in the initial hours of the experiments. The influence of parameters such as PEI loading, adsorption and desorption temperature, particle size, and PEI molecular weight on the adsorption behavior were investigated. The mild regeneration temperatures required could allow the use of waste heat available in many industrial processes as well as solar heat. CO2 adsorption from the air has a number of applications. Removal of CO2 from a closed environment, such as a submarine or space vehicles, is essential for life support. The supply of CO2-free air is also critical for alkaline fuel cells and batteries. Direct air capture of CO2 could also help mitigate the rising concerns about atmospheric CO2 concentration and associated climatic changes, while, at the same time, provide the first step for an anthropogenic carbon cycle.

Goeppert, A↗

CURRENT HELICITY OF ACTIVE REGIONS AS A TRACER OF LARGE-SCALE SOLAR MAGNETIC HELICITY

We demonstrate that the current helicity observed in solar active regions traces the magnetic helicity of the large-scale dynamo generated field. We use an advanced two-dimensional mean-field dynamo model with dynamo saturation based on the evolution of the magnetic helicity and algebraic quenching. For comparison, we also studied a more basic two-dimensional mean-field dynamo model with simple algebraic alpha-quenching only. Using these numerical models we obtained butterfly diagrams both for the small-scale current helicity and also for the large-scale magnetic helicity, and compared them with the butterfly diagram for the current helicity in active regions obtained from observations. This comparison shows that the current helicity of active regions, as estimated by -A {center_dot} B evaluated at the depth from which the active region arises, resembles the observational data much better than the small-scale current helicity calculated directly from the helicity evolution equation. Here B and A are, respectively, the dynamo generated mean magnetic field and its vector potential. A theoretical interpretation of these results is given.

79 ASTRONOMY AND ASTROPHYSICS↗

Controlling the Nucleation and Growth of Silver on Palladium Nanocubes by Manipulating the Reaction Kinetics

By manipulating the rate at which Ag atoms were generated from a precursor, the nucleation and growth of Ag on Pd nanocubes with six equivalent {l_brace}100{r_brace} facets were controlled to generate three different types of bimetallic nanocrystals: Pd-Ag hybrid dimers, Pd-Ag eccentric nanobars, and Pd{at}Ag core-shell nanocrystals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗