Theoretical and experimental study on the detection limit of the micro-ring resonator based ultrasound point detectors
Not Available
Engineering topics
Publications and source records attributed to Zhang, Hao F..
Not Available
Nucleoporins (NUPs) comprise nuclear pore complexes, gateways for nucleocytoplasmic transport. As primary human keratinocytes switch from the progenitor state towards differentiation, most NUPs are strongly downregulated, with NUP93 being the most downregulated NUP in this process. To determine if this NUP downregulation is accompanied by a reduction in nuclear pore numbers, we leveraged Stochastic Optical Reconstruction Microscopy. No significant changes in nuclear pore numbers were detected using three independent NUP antibodies; however, NUP reduction in other subcellular compartments such as the cytoplasm was identified. To investigate how NUP reduction influences keratinocyte differentiation, we knocked down NUP93 in keratinocytes in the progenitor-state culture condition. NUP93 knockdown diminished keratinocytes’ clonogenicity and epidermal regenerative capacity, without drastically affecting nuclear pore numbers or permeability. Using transcriptome profiling, we identified that NUP93 knockdown induces differentiation genes related to both mechanical and immune barrier functions, including the activation of known NF-κB target genes. Consistently, keratinocytes with NUP93 knockdown exhibited increased nuclear localization of the NF-κB p65/p50 transcription factors, and increased NF-κB reporter activity. Taken together, these findings highlight the gene regulatory roles contributed by differential NUP expression levels in keratinocyte differentiation, independent of nuclear pore numbers.
Explore the source record for details and available documents.
3D photoacoustic computed tomography (3D-PACT) has made great advances in volumetric imaging of biological tissues, with high spatial-temporal resolutions and large penetration depth. The development of 3D-PACT requires high-performance acoustic sensors with a small size, large detection bandwidth, and high sensitivity. In this work, we present a new high-frequency 3D-PACT system that uses a microring resonator (MRR) as the acoustic sensor. The MRR sensor has a size of 80 μ m in diameter and was fabricated using the nanoimprint lithography technology. Using the MRR sensor, we have developed a transmission-mode 3D-PACT system that has achieved a detection bandwidth of ~23 MHz, an imaging depth of ~8 mm, a lateral resolution of 114 μ m, and an axial resolution of 57 μ m. We have demonstrated the 3D PACT’s performance on in vitro phantoms, ex vivo mouse brain, and in vivo mouse ear and tadpole. The MRR-based 3D-PACT system can be a promising tool for structural, functional, and molecular imaging of biological tissues at depths.
We experimentally investigated several intra-molecular coordinate and environmental changes as potential causes of single-molecule fluorescence spectral heterogeneities (smFSH). Here, we developed a high-throughput single-molecule spectroscopy technique to analyze more than 5,000 single-molecule emission spectra from each of nine commonly used fluorophores with different structural rigidities deposited on substrates with different polarities. We observed an unexpected high smFSH from structurally rigid Rhodamine B compared with a structurally flexible Cyanine dye - Alexa Fluor 647. Based on experimentally measured smFSH, we ruled out the system’s noise uncertainty, single-molecule spectral diffusion, and environmental polarity as the primary causes of the high smFSH. We found that the rotational flexibility of N, N-dialkylated groups contributed to the smFSH. With the high smFSH observed in structurally more rigid model fluorophores, we speculated that other intra-molecular coordinate and environmental changes might also contribute to the high smFSH in Rhodamines.