Search NASA⌕ Search

Engineering topics

Zhang, X Z

Publications and source records attributed to Zhang, X Z.

Status of the laser ion source at IMP

A laser (Nd:YAG laser, 3 J, 1064 nm, 8-10 ns) ion source has been built and under development at IMP to provide pulsed high-charge-state heavy ion beams to a radio frequency quadrupole (RFQ) for upgrading the IMP accelerators with a new low-energy beam injector. The laser ion source currently operates in a direct plasma injection scheme to inject the high charge state ions produced from a solid target into the RFQ. The maximum power density on the target was about 8.4 x 10{sup 12} W/cm{sup 2}. The preliminary experimental results will be presented and discussed in this paper.

43 PARTICLE ACCELERATORS↗

Performance and operation of advanced superconducting electron cyclotron resonance ion source SECRAL at 24 GHz

SECRAL (superconducting ECR ion source with advanced design in Lanzhou) ion source has been in routine operation for Heavy Ion Research Facility in Lanzhou (HIRFL) accelerator complex since May 2007. To further enhance the SECRAL performance in order to satisfy the increasing demand for intensive highly charged ion beams, 3-5 kW high power 24 GHz single frequency and 24 GHz +18 GHz double frequency with an aluminum plasma chamber were tested, and some exciting results were produced with quite a few new record highly charged ion beam intensities, such as {sup 129}Xe{sup 35+} of 64 e{mu}A, {sup 129}Xe{sup 42+} of 3 e{mu}A, {sup 209}Bi{sup 41+} of 50 e{mu}A, {sup 209}Bi{sup 50+} of 4.3 e{mu}A and {sup 209}Bi{sup 54+} of 0.2 e{mu}A. In most cases SECRAL is operated at 18 GHz to deliver highly charged heavy ion beams for the HIRFL accelerator, only for those very high charge states and very heavy ion beams such as {sup 209}Bi{sup 36+} and {sup 209}Bi{sup 41+}, SECRAL has been operated at 24 GHz. The total operation beam time provided by SECRAL up to July 2011 has exceeded 7720 hours. In this paper, the latest performance, development, and operation status of SECRAL ion source are presented. The latest results and reliable long-term operation for the HIRFL accelerator have demonstrated that SECRAL performance for production of highly charged heavy ion beams remains improving at higher RF power with optimized tuning.

43 PARTICLE ACCELERATORS↗

Development of DRAGON electron cyclotron resonance ion source at Institute of Modern Physics

A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet.

43 PARTICLE ACCELERATORS↗

A 2.45 GHz electron cyclotron resonance proton ion source and a dual-lens low energy beam transport

The structure and preliminary commissioning results of a new 2.45 GHz ECR proton ion source and a dual-lens low energy beam transport (LEBT) system are presented in this paper. The main magnetic field of the ion source is provided by a set of permanent magnets with two small electro-solenoid magnets at the injection and the extraction to fine tune the magnetic field for better microwave coupling. A 50 keV pulsed proton beam extracted by a three-electrode mechanism passes through the LEBT system of length of 1183 mm. This LEBT consists of a diagnosis chamber, two Glaser lenses, two steering magnets, and a final beam defining cone. A set of inner permanent magnetic rings is embedded in each of the two Glaser lenses to produce a flatter axial-field to reduce the lens aberrations.

43 PARTICLE ACCELERATORS↗

Study of ion beam transport from the SECRAL electron cyclotron resonance ion source at the Institute of Modern Physics

Ion beam transport from the Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) electron cyclotron resonance ion source was studied at the Institute of Modern Physics during 2010. Particle-in-cell simulations and experimental results have shown that both space charge and magnetic aberrations lead to a larger beam envelope and emittance growth. In the existing SECRAL extraction beam line, it has been shown that raising the solenoid lens magnetic field reduces aberrations in the subsequent dipole and results in lower emittance. Detailed beam emittance measurements are presented in this paper.

43 PARTICLE ACCELERATORS↗

Effects of tensor interaction on pseudospin energy splitting and shell correction

In the framework of a Skyrme-Hartree-Fock approach combined with Bardeen-Cooper-Schrieffer (BCS) method, the role of the tensor force on the pseudospin energy splitting for tin isotope chain is investigated. The tensor force turns out to obviously affect the pseudospin energy splitting of the spin-unsaturated nuclei. Since the tensor force shifts the single-particle levels, it modifies the single-particle level density and the shell correction energy thereof. The influence of the tensor interaction on shell correction energy is considerable according to our analysis taking a magic nucleus {sup 132}Sn as well as a superheavy nucleus {sup 298}114 as examples. This modification of the shell correction energy due to the tensor component affects the stability of the superheavy nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic study of tensor effects in shell evolution

In the framework of the Hartree-Fock-Bogoliubov approach with the Skyrme interactions SLy5, SLy5+T, SLy5+T{sub w}, and several sets of the TIJ parametrizations (Skyrme effective interaction parametrizations including the tensor terms), the effect of the tensor force on the shell evolution at Z,N=8, 20, and 28 is investigated. It is shown that the evolution of the gap (defined as the energy difference between the last occupied and first unoccupied single-particle orbits) with SLy5+T is similar to that with SLy5+T{sub w}, and the gap values with SLy5+T are smaller than those with SLy5+T{sub w} in the cases of Z,N=8, 20. At Z, N = 28, the gap values with SLy5 are smaller than those with SLy5+T and larger than those with SLy5+T{sub w}. To understand these features, we analyze the spin-orbit potentials with and without the tensor contributions and the radial wave functions of relevant orbits. Meanwhile, we find that the deviation of the calculated gaps with SLy5+T{sub w} from the experimental ones is larger than that with SLy5+T. This indicates that SLy5+T{sub w} is not suitable for investigating the properties of the ground-state gap evolution. Finally, it is seen that the gap evolutions with different sets of the TIJ parametrizations are similar to each other except for the ones with T22, and there is almost no difference between the tensor effect in gap evolution with the perturbative method and the one with the complete fitting method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin-isospin excitations as quantitative constraints for the tensor force

Gamow-Teller (GT) and charge-exchange spin-dipole (SD) excitation energies in {sup 90}Zr and {sup 208}Pb are systematically studied to determine the appropriate magnitude of the tensor terms of the Skyrme interactions. We have found that the centroid energies of GT and SD excitations are sensitive to the adopted strengths of the triplet-even and triplet-odd tensor interactions. Especially, the 1{sup -} SD state plays a crucial role in constraining the triplet-even part while the triplet-odd part is related rather to the GT peaks. Among the 36 TIJ parameter sets that include nonperturbatively the tensor terms, the four sets, T21, T32, T43, and T54, give reasonable results for the centroid energies in comparison with the experimental data. The sign and magnitude of the tensor terms are also discussed when these terms are added to the existing Skyrme interactions SGII and SLy5. The triplet-even strength can be constrained in a narrow range by using the available experimental data while further empirical data are needed to set a constraint on the triplet-odd term.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗